UptimeX MCP
An official MCP server provided by UptimeX that allows AI agents to manage uptime monitors. It enables listing current status and 24h stats, creating new monitors with just a URL, testing monitors against drafts without saving, updating or pausing monitors, and deleting monitors. It operates within the scope of a single project using a Bearer token for authentication.
Endpoint and access
No sign-in to connect and list tools. Individual tools may still need a vendor account, credentials, or permissions; check the documented prerequisites.
https://api.uptimex.co/mcpWhat its tools do
5 tools, grouped by the hints the server advertises. Hints are self-declared, not verified behavior.
Not annotated (5)
Checks and signals
Each line is separate evidence, not a trust score.
- Passed Endpoint answered the live check ·
- Passed Official MCP Registry namespace is tied to uptimex.co ·
- Passed Endpoint is on the registry namespace domain ·
- Uptime 100% over 90 days
- Availability 2 of 2 checks passed in 30 days
About UptimeX MCP
The UptimeX MCP server allows AI agents to manage uptime monitors within a single project. It supports listing current status and 24-hour statistics, creating new monitors by providing a URL, and updating or pausing existing monitors. Agents can also test monitor configurations against drafts without saving them or delete monitors entirely.
Connection to the server requires no sign-in, but individual tools may need a vendor account, credentials, or permissions. The server operates using a Bearer token for authentication within the project scope. Users must create an API key under Access tokens in Project Settings before using the tools.
An MCP client that supports remote HTTP servers is required to connect. The server provides a Streamable HTTP endpoint for communication. The live check verifies connection and tool discovery only, without establishing whether every tool works without an account, credentials, payment, or permissions.
What you can do with it
- List current monitor status and 24-hour statistics
- Create new monitors by providing a URL
- Test a monitor configuration against a draft without saving
- Pause or delete existing monitors
Source and maintenance
Protocol and capabilities
- Server
- uptimex 1.0.0
- MCP protocol negotiated in check
- 2025-11-25
- Tools
- 5 advertised
- Resources
- Not advertised
- Resource templates
- Not advertised
- Prompts
- 1 advertised
{
"tools": {},
"prompts": {}
}Server-provided instructions
Untrusted server output shown for inspection. It is not Koskamo guidance and is excluded from knowledge search.
Tools
5 advertised
list_monitors
List all of the authenticated user's monitors with current status and 24h stats.
{
"type": "object",
"properties": {},
"additionalProperties": false
}create_monitor
Create a monitor. Returns the created monitor.
{
"type": "object",
"required": [
"url"
],
"properties": {
"url": {
"type": "string",
"description": "Target URL (http/https, public host)."
},
"name": {
"type": "string"
},
"method": {
"type": "string",
"description": "HEAD (default) is forced to GET when content_rules are set."
},
"slow_ms": {
"type": "integer",
"description": "Latency at/above this counts as 'slow'."
},
"check_ssl": {
"type": "boolean",
"description": "https only: report a certificate/TLS failure as a distinct SSL problem instead of a generic connection error. Off by default."
},
"timeout_ms": {
"type": "integer",
"description": "Request timeout, clamped 1000–60000."
},
"check_domain": {
"type": "boolean",
"description": "Look up the domain's registration expiry via RDAP and warn before it lapses. Off by default."
},
"interval_sec": {
"type": "integer",
"description": "Check interval; floored to plan minimum (free 300, pro 60)."
},
"request_body": {
"type": "string",
"description": "Body for write methods (POST/PUT/PATCH/DELETE); rejected with GET/HEAD. Sent with EVERY scheduled check — use test data, not real customer writes. application/json unless a Content-Type header overrides."
},
"content_rules": {
"type": "array",
"description": "Up to 4 body rules (text_contains/text_absent/json_field)."
},
"expect_status": {
"type": [
"integer",
"null"
],
"description": "Exact status required; null/0 = any 2xx/3xx."
},
"fail_threshold": {
"type": "integer"
},
"request_headers": {
"type": "array",
"description": "Up to 4 request headers ({name,value,type?})."
},
"follow_redirects": {
"type": "boolean",
"description": "Follow 3xx redirects and judge the final response. Off (default) treats a 3xx as reachable."
},
"recover_threshold": {
"type": "integer"
}
},
"additionalProperties": false
}update_monitor
Update fields of an existing monitor (partial). Only provided fields change.
{
"type": "object",
"required": [
"id"
],
"properties": {
"id": {
"type": "string"
},
"url": {
"type": "string",
"description": "Target URL (http/https, public host)."
},
"name": {
"type": "string"
},
"method": {
"type": "string",
"description": "HEAD (default) is forced to GET when content_rules are set."
},
"enabled": {
"type": "boolean",
"description": "false = pause."
},
"slow_ms": {
"type": "integer",
"description": "Latency at/above this counts as 'slow'."
},
"check_ssl": {
"type": "boolean",
"description": "https only: report a certificate/TLS failure as a distinct SSL problem instead of a generic connection error. Off by default."
},
"timeout_ms": {
"type": "integer",
"description": "Request timeout, clamped 1000–60000."
},
"check_domain": {
"type": "boolean",
"description": "Look up the domain's registration expiry via RDAP and warn before it lapses. Off by default."
},
"interval_sec": {
"type": "integer",
"description": "Check interval; floored to plan minimum (free 300, pro 60)."
},
"request_body": {
"type": "string",
"description": "Body for write methods (POST/PUT/PATCH/DELETE); rejected with GET/HEAD. Sent with EVERY scheduled check — use test data, not real customer writes. application/json unless a Content-Type header overrides."
},
"content_rules": {
"type": "array",
"description": "Up to 4 body rules (text_contains/text_absent/json_field)."
},
"expect_status": {
"type": [
"integer",
"null"
],
"description": "Exact status required; null/0 = any 2xx/3xx."
},
"fail_threshold": {
"type": "integer"
},
"request_headers": {
"type": "array",
"description": "Up to 4 request headers ({name,value,type?})."
},
"follow_redirects": {
"type": "boolean",
"description": "Follow 3xx redirects and judge the final response. Off (default) treats a 3xx as reachable."
},
"recover_threshold": {
"type": "integer"
}
},
"additionalProperties": false
}delete_monitor
Delete a monitor by id.
{
"type": "object",
"required": [
"id"
],
"properties": {
"id": {
"type": "string"
}
},
"additionalProperties": false
}test_monitor
Run one check against a draft config without saving. Returns the check result.
{
"type": "object",
"required": [
"url"
],
"properties": {
"url": {
"type": "string",
"description": "Target URL (http/https, public host)."
},
"name": {
"type": "string"
},
"method": {
"type": "string",
"description": "HEAD (default) is forced to GET when content_rules are set."
},
"slow_ms": {
"type": "integer",
"description": "Latency at/above this counts as 'slow'."
},
"check_ssl": {
"type": "boolean",
"description": "https only: report a certificate/TLS failure as a distinct SSL problem instead of a generic connection error. Off by default."
},
"timeout_ms": {
"type": "integer",
"description": "Request timeout, clamped 1000–60000."
},
"check_domain": {
"type": "boolean",
"description": "Look up the domain's registration expiry via RDAP and warn before it lapses. Off by default."
},
"interval_sec": {
"type": "integer",
"description": "Check interval; floored to plan minimum (free 300, pro 60)."
},
"request_body": {
"type": "string",
"description": "Body for write methods (POST/PUT/PATCH/DELETE); rejected with GET/HEAD. Sent with EVERY scheduled check — use test data, not real customer writes. application/json unless a Content-Type header overrides."
},
"content_rules": {
"type": "array",
"description": "Up to 4 body rules (text_contains/text_absent/json_field)."
},
"expect_status": {
"type": [
"integer",
"null"
],
"description": "Exact status required; null/0 = any 2xx/3xx."
},
"fail_threshold": {
"type": "integer"
},
"request_headers": {
"type": "array",
"description": "Up to 4 request headers ({name,value,type?})."
},
"follow_redirects": {
"type": "boolean",
"description": "Follow 3xx redirects and judge the final response. Off (default) treats a 3xx as reachable."
},
"recover_threshold": {
"type": "integer"
}
},
"additionalProperties": false
}Prompts
1 advertised
register-monitor
Add an UptimeX uptime monitor (optionally for a given URL), guiding the flow.
- url
- URL to monitor (optional).
Resources
Not advertised
90-day uptime
A lightweight connection check about every six hours, sampled on hosts with many listings. It shows the server answered, not that its tools work.
- 2026-11-17: 2 of 2 checks answered
- 2026-11-18: 5 of 5 checks answered
- 2026-11-19: 4 of 4 checks answered
- 2026-11-20: 3 of 3 checks answered
- 2026-11-21: 4 of 4 checks answered
- 2026-11-22: 4 of 4 checks answered
- 2026-11-23: 3 of 3 checks answered
- 2026-11-24: 2 of 2 checks answered
30-day availability
Aggregated from read-only remote checks; this is not a tool-execution or security guarantee.
- Successful checks
- 2 of 2 (100%)
- Average latency
- 1880 ms
- 95th percentile latency
- 2671 ms
Maintenance history
Public check and source-refresh events. Editorial and ownership records remain private.
- · probe · passed · 2759 ms · 5 tool(s), 1 prompt(s)
- · probe · passed · 1001 ms · metadata changed · 5 tool(s), 1 prompt(s)
Connect from your client
Each snippet registers the same endpoint; pick the client you use.
Claude Code
claude mcp add --transport http uptimex-mcp https://api.uptimex.co/mcpCodex
codex mcp add uptimex-mcp --url https://api.uptimex.co/mcpCursor
{
"mcpServers": {
"uptimex-mcp": {
"url": "https://api.uptimex.co/mcp"
}
}
}Cline
{
"mcpServers": {
"uptimex-mcp": {
"type": "streamableHttp",
"url": "https://api.uptimex.co/mcp",
"disabled": false
}
}
}VS Code
{
"servers": {
"uptimex-mcp": {
"type": "http",
"url": "https://api.uptimex.co/mcp"
}
}
}Gemini CLI
gemini mcp add --transport http uptimex-mcp https://api.uptimex.co/mcpClaude Desktop
https://api.uptimex.co/mcpWindsurf
{
"mcpServers": {
"uptimex-mcp": {
"serverUrl": "https://api.uptimex.co/mcp"
}
}
}Let your agent find its tools
Find servers like UptimeX MCP from your agent. Add Koskamo once to search the index for endpoints, access requirements, and client setup. Public discovery needs no key.
Other cloud and infrastructure servers
Frequently asked questions
- Can I use UptimeX MCP without an API key?
- No. An API key for the project is required. Create one under Access tokens in Project Settings before using the tools.
- Does the server support testing monitors without saving?
- Yes. The `test_monitor` tool allows testing a monitor configuration against a draft without saving it.
- What is the scope of the UptimeX MCP server?
- The server operates within the scope of a single project using a Bearer token for authentication.
- Can I create new monitors with this server?
- Yes. The `create_monitor` tool enables creating new monitors by providing a URL.
Do you run UptimeX MCP?
Prove ownership with a DNS record, a well-known file, or your Official MCP Registry entry, and your edits publish immediately. Proofs are re-checked weekly; admins can still hide or remove a listing.