Koskamo

The Grate Guys MCP

An official MCP server providing engineering calculators and code checkers for metal grating, drainage, and fabrication. It allows agents to compute load spans, check building code compliance for guardrails and stairs, calculate steel weights, and determine galvanizing requirements for custom metalwork projects.

Endpoint and access

No sign-in to connect and list tools. Individual tools may still need a vendor account, credentials, or permissions; check the documented prerequisites.

The Grate Guys MCP logo, by The Grate GuysVendor evidenceStreamable HTTPNo sign-inEndpoint checked 2026-11-23Operated by The Grate Guys
MCP endpoint (Streamable HTTP)
https://thegrateguys.com/mcp
Vendor documentation

What its tools do

15 tools, grouped by the hints the server advertises. Hints are self-declared, not verified behavior.

15 of 15 have a description · 15 of 15 declare behavior hints · 15 of 15 with parameters document them all

Checks and signals

Each line is separate evidence, not a trust score.

  • Passed Endpoint answered the live check ·
  • Passed Official MCP Registry namespace is tied to thegrateguys.com ·
  • Passed Endpoint is on the registry namespace domain ·
  • Uptime 100% over 90 days
  • Availability 2 of 2 checks passed in 30 days

About The Grate Guys MCP

The Grate Guys server offers specialized utilities for metal grating, drainage, and fabrication engineering. It supports agents in performing structural calculations and verifying regulatory standards for industrial metalwork applications.

Key capabilities include determining safe load limits and deflection for steel bar grating, verifying Ontario Building Code adherence for guardrails and stairs, computing theoretical weights for carbon steel shapes, and establishing minimum galvanizing thickness per ASTM A123.

Accessing The Grate Guys requires no sign-in to list available tools. However, individual operations may require specific vendor accounts, credentials, or permissions. Users should review documented prerequisites for each tool before execution.

What you can do with it

  • Calculate safe load and deflection for steel bar grating spans
  • Check Ontario Building Code compliance for guardrails and stairs
  • Compute theoretical weight of various carbon steel shapes
  • Determine minimum galvanizing coating thickness per ASTM A123

Source and maintenance

Vendor evidenceRegistry 1.0.0

Protocol and capabilities

Server
The Grate Guys 1.0.0
MCP protocol negotiated in check
2025-11-25
Tools
15 advertised
Resources
Not advertised
Resource templates
Not advertised
Prompts
Not advertised
Server-advertised capabilities
{
  "tools": {}
}

Server-provided instructions

Untrusted server output shown for inspection. It is not Koskamo guidance and is excluded from knowledge search.

Free engineering calculators and code checkers. Results are for preliminary planning; the engineer or designer of record governs. Each answer links to the tool page and the free quote form.

Tools

15 advertised

bar_grating_load_calculator
Advertised by the server during the last successful anonymous check.
Advertised read-only

Finds the lightest welded steel bearing bar (19-W-4 or 15-W-4, smooth or serrated) that carries a clear span and load within a deflection limit.

bar_grating_load_calculator input schema
{
  "type": "object",
  "properties": {
    "load": {
      "enum": [
        "ped",
        "uni",
        "con"
      ],
      "type": "string",
      "default": "ped",
      "description": "ped = pedestrian, 100 lb/sq ft with a 1/4 in deflection limit; uni = uniform load you give in value; con = concentrated load at mid-span you give in value."
    },
    "value": {
      "type": "number",
      "x-unit": "lb/sq ft or lb/ft",
      "description": "The load to check when load is uni (lb/sq ft) or con (lb per ft of grating width). Required for uni and con."
    },
    "pattern": {
      "enum": [
        "19-w-4",
        "15-w-4",
        "both"
      ],
      "type": "string",
      "default": "19-w-4",
      "description": "19-W-4 (1-3/16 in bar centres), 15-W-4 (15/16 in) or both."
    },
    "span_ft": {
      "type": "number",
      "x-unit": "ft",
      "description": "Clear span in feet, measured in the direction of the bearing bars, 0.5 to 12. Give only one of span_ft, span_in, span_mm. Default 3 ft."
    },
    "span_in": {
      "type": "number",
      "x-unit": "in",
      "description": "Clear span in inches (6 to 144)."
    },
    "span_mm": {
      "type": "number",
      "x-unit": "mm",
      "description": "Clear span in millimetres (152 to 3658)."
    },
    "surface": {
      "enum": [
        "smooth",
        "serrated"
      ],
      "type": "string",
      "default": "smooth",
      "description": "Serrated bars are calculated 1/4 in shallower."
    },
    "area_sqft": {
      "type": "number",
      "x-unit": "sq ft",
      "description": "Optional total grating area for an approximate total weight."
    },
    "deflection": {
      "enum": [
        "0.25",
        "0.125",
        "0.375",
        "span240",
        "span360",
        "none"
      ],
      "type": "string",
      "x-unit": "in",
      "default": "0.25",
      "description": "Deflection limit in inches, span240 (span / 240), span360 (span / 360) or none (strength only). Ignored for ped."
    }
  },
  "additionalProperties": false
}
bar_grating_load_calculator annotations
{
  "title": "Steel bar grating load and span calculator",
  "readOnlyHint": true
}
bar_grating_load_tables
Advertised by the server during the last successful anonymous check.
Advertised read-only

Looks up the safe uniform load (U), safe concentrated load (C), deflections and weight for welded steel bar grating by bearing bar size and span.

bar_grating_load_tables input schema
{
  "type": "object",
  "properties": {
    "bar": {
      "enum": [
        "1x1/8",
        "1x3/16",
        "1-1/4x1/8",
        "1-1/4x3/16",
        "1-1/2x1/8",
        "1-1/2x3/16",
        "1-3/4x3/16",
        "2x3/16",
        "2-1/2x3/16"
      ],
      "type": "string",
      "description": "Optional bearing bar size, depth x thickness in inches, for example 1-1/4x3/16. Leave out for every bar."
    },
    "pattern": {
      "enum": [
        "19-w-4",
        "15-w-4"
      ],
      "type": "string",
      "default": "19-w-4",
      "description": "19-W-4 or 15-W-4 pattern."
    },
    "span_ft": {
      "type": "number",
      "x-unit": "ft",
      "description": "Optional clear span in feet (1 to 12). Tabulated spans are 2 to 8 ft in 6 in steps. Leave out for every tabulated span."
    },
    "surface": {
      "enum": [
        "smooth",
        "serrated"
      ],
      "type": "string",
      "default": "smooth",
      "description": "Serrated bars act 1/4 in shallower."
    }
  },
  "additionalProperties": false
}
bar_grating_load_tables annotations
{
  "title": "Bar grating load tables (19-W-4 and 15-W-4)",
  "readOnlyHint": true
}
aluminum_stainless_bar_grating_load_calculator
Advertised by the server during the last successful anonymous check.
Advertised read-only

Safe load, deflection and the lightest bearing bar for aluminum 6063-T6 and stainless 304, 316, 304L and 316L bar grating at 1-3/16 in bar centres.

aluminum_stainless_bar_grating_load_calculator input schema
{
  "type": "object",
  "properties": {
    "load": {
      "enum": [
        "ped",
        "uni",
        "con"
      ],
      "type": "string",
      "default": "ped",
      "description": "ped = pedestrian, 100 lb/sq ft with a 1/4 in deflection limit; uni = uniform load you give in value; con = concentrated load at mid-span you give in value."
    },
    "value": {
      "type": "number",
      "x-unit": "lb/sq ft or lb/ft",
      "description": "The load to check when load is uni (lb/sq ft) or con (lb per ft of grating width). Required for uni and con."
    },
    "span_in": {
      "type": "number",
      "x-unit": "in",
      "description": "Clear span in inches, 24 to 108 (the range of the published tables). Give only one of span_in, span_mm. Default 36 in."
    },
    "span_mm": {
      "type": "number",
      "x-unit": "mm",
      "description": "Clear span in millimetres, 610 to 2743."
    },
    "material": {
      "enum": [
        "al-6063",
        "ss-304-316",
        "ss-304l-316l"
      ],
      "type": "string",
      "default": "al-6063",
      "description": "Aluminum 6063-T6, stainless 304 or 316, or stainless 304L or 316L."
    },
    "deflection": {
      "enum": [
        "0.25",
        "0.125",
        "0.375",
        "span240",
        "span360",
        "none"
      ],
      "type": "string",
      "x-unit": "in",
      "default": "0.25",
      "description": "Deflection limit in inches, span240 (span / 240), span360 (span / 360) or none (strength only). Ignored for ped."
    }
  },
  "additionalProperties": false
}
aluminum_stainless_bar_grating_load_calculator annotations
{
  "title": "Aluminum and stainless bar grating load calculator",
  "readOnlyHint": true
}
accessible_grating_opening_checker
Advertised by the server during the last successful anonymous check.
Advertised read-only

Checks the clear opening between bearing bars against the Ontario Building Code 13 mm limit for barrier-free paths of travel, and the widest bar spacing that would pass.

accessible_grating_opening_checker input schema
{
  "type": "object",
  "properties": {
    "pattern": {
      "enum": [
        "19-w-4",
        "15-w-4",
        "custom"
      ],
      "type": "string",
      "default": "19-w-4",
      "description": "19-W-4 (1-3/16 in centres), 15-W-4 (15/16 in centres) or custom (give spacing_in)."
    },
    "spacing_in": {
      "type": "number",
      "x-unit": "in",
      "description": "Bearing bar centre-to-centre spacing in inches. Required when pattern is custom."
    },
    "bar_thickness_in": {
      "type": "number",
      "x-unit": "in",
      "default": 0.125,
      "description": "Bearing bar thickness in inches, for example 0.125 (1/8), 0.1875 (3/16), 0.25 (1/4)."
    }
  },
  "additionalProperties": false
}
accessible_grating_opening_checker annotations
{
  "title": "Accessible grating opening checker (13 mm rule)",
  "readOnlyHint": true
}
galvanizing_coating_thickness_calculator
Advertised by the server during the last successful anonymous check.
Advertised read-only

Minimum average hot-dip galvanized coating grade by steel category and thickness, in mils, microns and ounces of zinc per square foot, with total zinc for a surface area.

galvanizing_coating_thickness_calculator input schema
{
  "type": "object",
  "properties": {
    "category": {
      "enum": [
        "shapes",
        "strip",
        "plate",
        "pipe",
        "wire",
        "rebar"
      ],
      "type": "string",
      "default": "shapes",
      "description": "shapes = structural shapes (angles, channels, beams); strip = strip and bar; plate; pipe = pipe and tubing; wire; rebar = reinforcing bar."
    },
    "area_sqft": {
      "type": "number",
      "x-unit": "sq ft",
      "description": "Optional surface area to be coated, for the minimum zinc weight."
    },
    "thickness_in": {
      "type": "number",
      "x-unit": "in",
      "description": "Steel thickness in inches. Give only one of thickness_in, thickness_mm. Default 0.1875 in."
    },
    "thickness_mm": {
      "type": "number",
      "x-unit": "mm",
      "description": "Steel thickness in millimetres."
    }
  },
  "additionalProperties": false
}
galvanizing_coating_thickness_calculator annotations
{
  "title": "Galvanizing coating thickness calculator (ASTM A123)",
  "readOnlyHint": true
}
guard_and_railing_code_checker_ontario
Advertised by the server during the last successful anonymous check.
Advertised read-only

Whether a guard is required, its minimum height, opening limit, climbing rule and design loads under the Ontario Building Code Part 9 and Part 3 for a described situation.

guard_and_railing_code_checker_ontario input schema
{
  "type": "object",
  "properties": {
    "use": {
      "enum": [
        "normal",
        "equip"
      ],
      "type": "string",
      "default": "normal",
      "description": "normal = ordinary guard; equip = access way to an equipment platform where many people are improbable."
    },
    "drop": {
      "type": "number",
      "x-unit": "per the unit parameter",
      "default": 900,
      "description": "Drop to the adjacent surface within 1.2 m (4 ft). A guard is required above 600 mm (23.6 in)."
    },
    "unit": {
      "enum": [
        "mm",
        "in"
      ],
      "type": "string",
      "default": "mm",
      "description": "Unit of every length below."
    },
    "opening": {
      "type": "number",
      "x-unit": "per the unit parameter",
      "default": 95,
      "description": "Largest opening: the widest sphere that passes through the guard."
    },
    "location": {
      "enum": [
        "dwelling",
        "exthouse",
        "part9",
        "exit3"
      ],
      "type": "string",
      "default": "part9",
      "description": "dwelling = within a dwelling unit; exthouse = exterior serving one dwelling unit; part9 = other Part 9 building; exit3 = required exit in a larger (Part 3) building."
    },
    "industrial": {
      "type": "boolean",
      "default": false,
      "description": "Industrial occupancy."
    },
    "loading_dock": {
      "type": "boolean",
      "default": false,
      "description": "Loading dock."
    },
    "planned_height": {
      "type": "number",
      "x-unit": "per the unit parameter",
      "default": 1070,
      "description": "Guard height you plan."
    },
    "stair_triangle": {
      "type": "number",
      "x-unit": "per the unit parameter",
      "description": "Optional stair triangle gap, widest sphere."
    },
    "maintenance_only": {
      "type": "boolean",
      "default": false,
      "description": "Access for maintenance only."
    },
    "height_above_grade": {
      "type": "number",
      "x-unit": "per the unit parameter",
      "default": 900,
      "description": "Walking surface height above grade."
    }
  },
  "additionalProperties": false
}
guard_and_railing_code_checker_ontario annotations
{
  "title": "Ontario guard and railing code checker",
  "readOnlyHint": true
}
steel_stair_calculator_ontario
Advertised by the server during the last successful anonymous check.
Advertised read-only

Allowed riser counts, riser height, tread run, flights, width, headroom and handrail height for a total rise under Ontario Building Code Part 9.

steel_stair_calculator_ontario input schema
{
  "type": "object",
  "properties": {
    "run": {
      "type": "number",
      "x-unit": "per the unit parameter",
      "default": 280,
      "description": "Tread run you want (nosing to nosing)."
    },
    "unit": {
      "enum": [
        "mm",
        "in"
      ],
      "type": "string",
      "default": "mm",
      "description": "Unit of every length below."
    },
    "width": {
      "type": "number",
      "x-unit": "per the unit parameter",
      "default": 1000,
      "description": "Clear stair width."
    },
    "handrail": {
      "type": "number",
      "x-unit": "per the unit parameter",
      "default": 920,
      "description": "Handrail height above the nosing line."
    },
    "headroom": {
      "type": "number",
      "x-unit": "per the unit parameter",
      "default": 2100,
      "description": "Clear headroom over the stair."
    },
    "location": {
      "enum": [
        "dwelling",
        "exitres",
        "exitother"
      ],
      "type": "string",
      "default": "exitother",
      "description": "dwelling = within a dwelling unit or house; exitres = exit or public stair, residential building; exitother = exit or public stair, other building."
    },
    "stair_type": {
      "enum": [
        "private",
        "public",
        "service"
      ],
      "type": "string",
      "default": "public",
      "description": "private = inside or outside a house or single dwelling unit; public = every other stair; service = serves service rooms only (Table 9.8.4.1.)."
    },
    "total_rise": {
      "type": "number",
      "x-unit": "per the unit parameter",
      "default": 2800,
      "description": "Total rise, finished floor to finished floor. At least 375 mm (14.8 in)."
    }
  },
  "additionalProperties": false
}
steel_stair_calculator_ontario annotations
{
  "title": "Ontario steel stair calculator",
  "readOnlyHint": true
}
steel_weight_calculator
Advertised by the server during the last successful anonymous check.
Advertised read-only

Theoretical weight of carbon steel plate, flat bar, round bar, square bar, angle, square or rectangular tube and round pipe, in pounds and kilograms.

steel_weight_calculator input schema
{
  "type": "object",
  "properties": {
    "side": {
      "type": "number",
      "x-unit": "per the unit parameter",
      "description": "Side: square bar."
    },
    "unit": {
      "enum": [
        "in",
        "mm"
      ],
      "type": "string",
      "default": "in",
      "description": "Unit of every size and the length."
    },
    "wall": {
      "type": "number",
      "x-unit": "per the unit parameter",
      "description": "Wall thickness: tube and pipe."
    },
    "leg_a": {
      "type": "number",
      "x-unit": "per the unit parameter",
      "description": "Leg A: angle."
    },
    "leg_b": {
      "type": "number",
      "x-unit": "per the unit parameter",
      "description": "Leg B: angle."
    },
    "shape": {
      "enum": [
        "plate",
        "flat",
        "round",
        "square",
        "angle",
        "tube",
        "pipe"
      ],
      "type": "string",
      "default": "plate",
      "description": "plate or sheet, flat bar, round bar, square bar, angle, square or rectangular tube, round pipe or tube."
    },
    "width": {
      "type": "number",
      "x-unit": "per the unit parameter",
      "description": "Width: plate, flat bar, tube."
    },
    "height": {
      "type": "number",
      "x-unit": "per the unit parameter",
      "description": "Height: rectangular tube."
    },
    "length": {
      "type": "number",
      "x-unit": "per the unit parameter",
      "default": 12,
      "description": "Length of one piece."
    },
    "diameter": {
      "type": "number",
      "x-unit": "per the unit parameter",
      "description": "Diameter: round bar."
    },
    "quantity": {
      "type": "number",
      "default": 1,
      "description": "Number of pieces."
    },
    "thickness": {
      "type": "number",
      "x-unit": "per the unit parameter",
      "description": "Thickness: plate, flat bar, angle."
    },
    "outside_diameter": {
      "type": "number",
      "x-unit": "per the unit parameter",
      "description": "Outside diameter: pipe."
    }
  },
  "additionalProperties": false
}
steel_weight_calculator annotations
{
  "title": "Steel weight calculator",
  "readOnlyHint": true
}
trench_drain_grate_load_class
Advertised by the server during the last successful anonymous check.
Advertised read-only

The EN 1433 load class, A 15 to F 900, and its test load in kN for where a trench drain goes and what drives or rolls over it.

trench_drain_grate_load_class input schema
{
  "type": "object",
  "properties": {
    "application": {
      "enum": [
        "footpath",
        "domestic-driveway",
        "private-road",
        "public-space",
        "car-park",
        "retail-parking",
        "petrol-forecourt",
        "vans-light-trucks",
        "public-road-trucks",
        "logistics-bus",
        "industrial-forklift",
        "port-airport"
      ],
      "type": "string",
      "default": "domestic-driveway",
      "description": "footpath = Footpath, patio, pool deck or cycle path; domestic-driveway = Domestic driveway (cars and light vans); private-road = Private road or slow residential lane; public-space = Public space or plaza with light vehicles; car-park = Car park (slow, light vehicles); retail-parking = Supermarket or retail parking lot; petrol-forecourt = Petrol station forecourt (fuel delivery trucks cross it); vans-light-trucks = Vans and light trucks up to 7.5 t; public-road-trucks = Public road, carriageway or commercial driveway with trucks; logistics-bus = Logistics area or bus station; industrial-forklift = Industrial yard or loading dock apron with forklifts; port-airport = Container terminal, port, airport or aircraft apron. If more than one applies, pick the heaviest."
    }
  },
  "additionalProperties": false
}
trench_drain_grate_load_class annotations
{
  "title": "Trench drain grate load class picker (EN 1433)",
  "readOnlyHint": true
}
bollard_spacing_and_footing_calculator
Advertised by the server during the last successful anonymous check.
Advertised read-only

Counts the bollards for a frontage and clear gap, checks the gap against vehicle and wheelchair guidance, gives typical footing and concrete for a standard (not crash rated) steel pipe bollard, and explains crash ratings.

bollard_spacing_and_footing_calculator input schema
{
  "type": "object",
  "properties": {
    "ends": {
      "enum": [
        "between-fixed-points",
        "bollard-at-each-end"
      ],
      "type": "string",
      "default": "between-fixed-points",
      "description": "between-fixed-points: the frontage runs between two fixed obstructions such as walls, and the end gaps also count. bollard-at-each-end: the frontage is measured outside edge to outside edge of the end bollards."
    },
    "pipe": {
      "enum": [
        "4",
        "6",
        "8",
        "10"
      ],
      "type": "string",
      "default": "6",
      "description": "Nominal pipe size in inches (outside diameter 4.5, 6.625, 8.625, 10.75 in). Footing figures exist for 6 and 8."
    },
    "rating": {
      "enum": [
        "M30",
        "M40",
        "M50",
        "P1",
        "P2",
        "P3",
        "P4",
        "K4",
        "K8",
        "K12",
        "PAS68",
        "IWA14"
      ],
      "type": "string",
      "description": "Optional crash rating to explain."
    },
    "height_in": {
      "type": "number",
      "x-unit": "in",
      "default": 36,
      "description": "Pipe height above grade in inches (24 to 60). 36 in is the guide figure."
    },
    "frontage_m": {
      "type": "number",
      "x-unit": "m",
      "description": "Frontage to protect in metres."
    },
    "max_gap_in": {
      "type": "number",
      "x-unit": "in",
      "description": "Largest clear gap between bollards you will allow, in inches (12 to 120). Give only one of max_gap_in, max_gap_mm. Default 48 in."
    },
    "max_gap_mm": {
      "type": "number",
      "x-unit": "mm",
      "description": "Largest clear gap in millimetres."
    },
    "frontage_ft": {
      "type": "number",
      "x-unit": "ft",
      "description": "Frontage to protect in feet (1 to 1,000). Give only one of frontage_ft, frontage_m. Default 40 ft."
    },
    "footing_shape": {
      "enum": [
        "square",
        "round"
      ],
      "type": "string",
      "default": "square",
      "description": "Footing shape."
    },
    "footing_width_in": {
      "type": "number",
      "x-unit": "in",
      "default": 18,
      "description": "Footing width in inches (12 to 48). 18 in square is the figure for a 6 in pipe in the cited guide."
    }
  },
  "additionalProperties": false
}
bollard_spacing_and_footing_calculator annotations
{
  "title": "Bollard planner: spacing, count and footing",
  "readOnlyHint": true
}
steel_beam_lintel_span_check
Advertised by the server during the last successful anonymous check.
Advertised read-only

The steel angle lintel or steel beam that the 2024 Ontario Building Code Part 9 tables list for an opening width in a brick or stone veneer wall or a masonry wall, with the 150 mm bearing rule. Not a stamped design.

steel_beam_lintel_span_check input schema
{
  "type": "object",
  "properties": {
    "wall": {
      "enum": [
        "veneer-brick-70",
        "veneer-brick-90",
        "veneer-stone-100",
        "solid-brick-100",
        "solid-stone-150"
      ],
      "type": "string",
      "default": "veneer-brick-90",
      "description": "veneer-brick-70 = 70 mm brick veneer; veneer-brick-90 = 90 mm brick veneer; veneer-stone-100 = 100 mm stone veneer; solid-brick-100 = masonry wall, 100 mm brick (Table 9.20.5.2.-A, exterior angle); solid-stone-150 = masonry wall, 100 mm brick plus 50 mm stone facing (Table 9.20.5.2.-A, exterior angle)."
    },
    "member": {
      "enum": [
        "angle",
        "beam"
      ],
      "type": "string",
      "default": "angle",
      "description": "angle = steel angle lintel; beam = steel beam supporting masonry veneer and a wood stud wall (veneer walls only)."
    },
    "bearing_mm": {
      "type": "number",
      "x-unit": "mm",
      "description": "Optional: the bearing length you have at each end, to check against the 150 mm minimum."
    },
    "opening_ft": {
      "type": "number",
      "x-unit": "ft",
      "description": "Clear opening width in feet."
    },
    "opening_mm": {
      "type": "number",
      "x-unit": "mm",
      "description": "Clear opening width in millimetres (300 to 6,000). Give only one of opening_mm, opening_ft. Default 2,000 mm."
    }
  },
  "additionalProperties": false
}
steel_beam_lintel_span_check annotations
{
  "title": "Steel lintel and beam span check (2024 Ontario Building Code Part 9)",
  "readOnlyHint": true
}
catch_basin_grate_and_frame_size_finder
Advertised by the server during the last successful anonymous check.
Advertised read-only

Names the Ontario Provincial Standard Drawing for a catch basin inlet type, checks the grate bearing on the frame ledge against the NAAMM minimum, gives the range of bearing bar lengths that sit on the ledge, and lists the EN 1433 load class for the traffic.

catch_basin_grate_and_frame_size_finder input schema
{
  "type": "object",
  "properties": {
    "inlet": {
      "enum": [
        "square-flat",
        "square-dished",
        "square-v",
        "birdcage",
        "overflow-perforated",
        "raised-circular",
        "curb-inlet",
        "curb-overflow"
      ],
      "type": "string",
      "default": "square-flat",
      "description": "square-flat = OPSD 400.020, General purpose frame and flat grate; square-dished = OPSD 400.010, Dished grate with an overflow path; square-v = OPSD 400.030, V grate; birdcage = OPSD 400.120, Birdcage grate; overflow-perforated = OPSD 400.110, Overflow flat grate with perforated openings; raised-circular = OPSD 400.070, Raised frame with a round grate; curb-inlet = OPSD 400.081, Curb inlet outside the roadway; curb-overflow = OPSD 400.090, Curb inlet overflow."
    },
    "seat_mm": {
      "type": "number",
      "x-unit": "mm",
      "default": 40,
      "description": "Width of the ledge the grate sits on, each end, in millimetres (0 to 300)."
    },
    "span_in": {
      "type": "number",
      "x-unit": "in",
      "description": "The same clear opening in inches."
    },
    "span_mm": {
      "type": "number",
      "x-unit": "mm",
      "description": "Clear opening between the frame ledges, in the direction the bearing bars will run, 100 to 3,000 mm. Give only one of span_mm, span_in. Default 500 mm."
    },
    "traffic": {
      "enum": [
        "pedestrian",
        "private-light",
        "public-light",
        "road-commercial",
        "industrial",
        "extreme"
      ],
      "type": "string",
      "default": "private-light",
      "description": "pedestrian = A 15; private-light = B 125; public-light = C 250; road-commercial = D 400; industrial = E 600; extreme = F 900."
    },
    "bar_depth_in": {
      "type": "number",
      "x-unit": "in",
      "default": 1.25,
      "description": "Depth of the grate bearing bars in inches (0.75 to 6), for example 1.25 or 2.5."
    }
  },
  "additionalProperties": false
}
catch_basin_grate_and_frame_size_finder annotations
{
  "title": "Catch basin grate and frame finder (OPSD type, bearing check, load class)",
  "readOnlyHint": true
}
fence_and_gate_post_spacing_and_weight
Advertised by the server during the last successful anonymous check.
Advertised read-only

Post count and spacing for a chain link or ornamental steel fence run, chain link footing depth and gate post size, and the weight and hinge loads of an ornamental steel gate leaf.

fence_and_gate_post_spacing_and_weight input schema
{
  "type": "object",
  "properties": {
    "panel": {
      "enum": [
        "chain-link",
        "ornamental"
      ],
      "type": "string",
      "default": "ornamental",
      "description": "chain-link (line posts 10 ft apart at most) or ornamental steel tubular pickets (8 ft, 96 in on center)."
    },
    "gap_in": {
      "type": "number",
      "x-unit": "in",
      "default": 3.5,
      "description": "Ornamental gate: largest gap between pickets in inches (4 in is the most the maker chart allows)."
    },
    "leaves": {
      "enum": [
        "1",
        "2"
      ],
      "type": "string",
      "default": 1,
      "description": "Single or double leaf gate."
    },
    "run_ft": {
      "type": "number",
      "x-unit": "ft",
      "default": 40,
      "description": "Length of the fence run in feet, not counting the gate (3 to 2,000)."
    },
    "gate_ft": {
      "type": "number",
      "x-unit": "ft",
      "default": 0,
      "description": "Gate opening in feet, 0 for no gate (0 to 24). The gate sits at the end of the run."
    },
    "tube_in": {
      "type": "number",
      "x-unit": "in",
      "default": 1.5,
      "description": "Ornamental gate frame: square tube outside size in inches."
    },
    "wall_in": {
      "type": "number",
      "x-unit": "in",
      "default": 0.12,
      "description": "Ornamental gate frame: tube wall in inches (0.12 is about 11 gauge)."
    },
    "height_ft": {
      "type": "number",
      "x-unit": "ft",
      "default": 6,
      "description": "Fence and gate height in feet (3 to 12)."
    },
    "mid_rails": {
      "type": "number",
      "default": 1,
      "description": "Ornamental gate: rails between the top and bottom rail."
    },
    "picket_in": {
      "type": "number",
      "x-unit": "in",
      "default": 0.5,
      "description": "Ornamental gate: square picket size in inches."
    },
    "post_od_in": {
      "type": "number",
      "x-unit": "in",
      "description": "Chain link line post outside diameter in inches, to get the footing diameter."
    },
    "hinge_spacing_in": {
      "type": "number",
      "x-unit": "in",
      "description": "Distance between the two hinges in inches. Default: gate height less 24 in."
    }
  },
  "additionalProperties": false
}
fence_and_gate_post_spacing_and_weight annotations
{
  "title": "Fence and gate post spacing, post count and gate weight",
  "readOnlyHint": true
}
trench_drain_flow_capacity_calculator
Advertised by the server during the last successful anonymous check.
Advertised read-only

The flow a trench drain has to handle from a paved area (rational method with Toronto City rainfall rates from Environment and Climate Change Canada) and the flow the channel carries (Manning), with the narrowest channel that works.

trench_drain_flow_capacity_calculator input schema
{
  "type": "object",
  "properties": {
    "c": {
      "type": "number",
      "description": "Optional runoff coefficient C (above 0, up to 1) to use instead of the top of the range for the surface."
    },
    "lining": {
      "enum": [
        "concrete-trowel",
        "concrete-float",
        "concrete-unfinished",
        "plastic-smooth"
      ],
      "type": "string",
      "default": "concrete-trowel",
      "description": "concrete-trowel = Concrete, trowel finish; concrete-float = Concrete, float finish; concrete-unfinished = Concrete, unfinished; plastic-smooth = Smooth plastic."
    },
    "period": {
      "enum": [
        "2",
        "5",
        "10",
        "25",
        "50",
        "100"
      ],
      "type": "string",
      "default": 10,
      "description": "Return period in years."
    },
    "area_m2": {
      "type": "number",
      "x-unit": "m2",
      "description": "Paved area draining to the trench in square metres (1 to 100,000). Give only one of area_m2, area_sqft. Default 500 m2."
    },
    "surface": {
      "enum": [
        "asphalt",
        "concrete",
        "brick",
        "drive-walk",
        "roof",
        "lawn-heavy-flat"
      ],
      "type": "string",
      "default": "asphalt",
      "description": "asphalt = Asphalt pavement; concrete = Concrete pavement; brick = Brick or interlocking paver; drive-walk = Driveway or walkway; roof = Roof; lawn-heavy-flat = Lawn, heavy soil, flat (2% or less). The top of the range for the surface is used unless c is given."
    },
    "depth_mm": {
      "type": "number",
      "x-unit": "mm",
      "default": 150,
      "description": "Water depth at the outlet end in millimetres (30 to 1,000)."
    },
    "duration": {
      "enum": [
        "5",
        "10",
        "15",
        "30"
      ],
      "type": "string",
      "default": 10,
      "description": "Storm duration in minutes, taken as the time of concentration."
    },
    "width_mm": {
      "type": "number",
      "x-unit": "mm",
      "default": 150,
      "description": "Channel internal width in millimetres (50 to 1,000)."
    },
    "area_sqft": {
      "type": "number",
      "x-unit": "sq ft",
      "description": "The same area in square feet."
    },
    "slope_pct": {
      "type": "number",
      "x-unit": "%",
      "default": 1,
      "description": "Channel slope in percent (0.05 to 20)."
    }
  },
  "additionalProperties": false
}
trench_drain_flow_capacity_calculator annotations
{
  "title": "Trench drain flow and channel capacity calculator",
  "readOnlyHint": true
}
loading_dock_height_and_leveler_check
Advertised by the server during the last successful anonymous check.
Advertised read-only

The grade a dock leveler works at between the lowest and highest truck bed you serve, against the 10% (electric) and 15% (gas or diesel) limits, the shortest standard leveler length that fits, and whether two makers published working ranges cover it.

loading_dock_height_and_leveler_check input schema
{
  "type": "object",
  "properties": {
    "equipment": {
      "enum": [
        "electric",
        "combustion"
      ],
      "type": "string",
      "default": "electric",
      "description": "electric = pallet, skid or electric fork trucks (10% grade limit); combustion = gas or diesel fork trucks (15%)."
    },
    "bed_low_in": {
      "type": "number",
      "x-unit": "in",
      "default": 44,
      "description": "Lowest truck bed height you serve, in inches (20 to 80). Vehicle beds range from 30 to 62 in."
    },
    "leveler_ft": {
      "enum": [
        "6",
        "8",
        "10",
        "12"
      ],
      "type": "string",
      "default": 8,
      "description": "Leveler length in feet. Standard lengths are 6, 8, 10 and 12 ft."
    },
    "bed_high_in": {
      "type": "number",
      "x-unit": "in",
      "default": 52,
      "description": "Highest truck bed height you serve, in inches."
    },
    "dock_height_in": {
      "type": "number",
      "x-unit": "in",
      "default": 48,
      "description": "Dock floor height above the driveway in inches (20 to 80). The most common dock height is 48 to 52 in."
    }
  },
  "additionalProperties": false
}
loading_dock_height_and_leveler_check annotations
{
  "title": "Loading dock height and leveler check",
  "readOnlyHint": true
}

Prompts

Not advertised

No prompt definitions available.

Resources

Not advertised

No resource definitions available.

90-day uptime

A lightweight connection check about every six hours, sampled on hosts with many listings. It shows the server answered, not that its tools work.

100% (46 of 46 checks answered)

  1. 2026-11-17: 2 of 2 checks answered
  2. 2026-11-18: 5 of 5 checks answered
  3. 2026-11-19: 4 of 4 checks answered
  4. 2026-11-20: 3 of 3 checks answered
  5. 2026-11-21: 4 of 4 checks answered
  6. 2026-11-22: 4 of 4 checks answered
  7. 2026-11-23: 3 of 3 checks answered
  8. 2026-11-24: 4 of 4 checks answered
  9. 2026-11-25: 4 of 4 checks answered
  10. 2026-11-26: 4 of 4 checks answered
  11. 2026-11-27: 4 of 4 checks answered
  12. 2026-11-28: 3 of 3 checks answered
  13. 2026-11-29: 2 of 2 checks answered

30-day availability

Aggregated from read-only remote checks; this is not a tool-execution or security guarantee.

Successful checks
2 of 2 (100%)
Average latency
539 ms
95th percentile latency
774 ms

Maintenance history

Public check and source-refresh events. Editorial and ownership records remain private.

  • · probe · passed · 800 ms · 15 tool(s)
  • · probe · passed · 277 ms · metadata changed · 15 tool(s)

Connect from your client

Each snippet registers the same endpoint; pick the client you use.

This server is operated by the named third party. Listing and endpoint checks are not an endorsement or a security audit. Review the operator's permissions, terms, and data handling before connecting. How listings are checked and corrected.

Claude Code

Run this once in a terminal. It registers the remote server. Use --scope project to write .mcp.json for the repo.
Claude Code configuration
claude mcp add --transport http the-grate-guys-mcp https://thegrateguys.com/mcp

Codex

Run this once. Codex stores MCP servers in ~/.codex/config.toml (or .codex/config.toml in a trusted project).
Codex configuration
codex mcp add the-grate-guys-mcp --url https://thegrateguys.com/mcp

Cursor

Merge this server into .cursor/mcp.json in your project, then enable the-grate-guys-mcp in your MCP settings.
Cursor configuration
{
  "mcpServers": {
    "the-grate-guys-mcp": {
      "url": "https://thegrateguys.com/mcp"
    }
  }
}

Cline

Merge this into cline_mcp_settings.json (Cline → MCP Servers → Configure).
Cline configuration
{
  "mcpServers": {
    "the-grate-guys-mcp": {
      "type": "streamableHttp",
      "url": "https://thegrateguys.com/mcp",
      "disabled": false
    }
  }
}

VS Code

Merge this server into .vscode/mcp.json. Use MCP: List Servers to start the-grate-guys-mcp and inspect its tools.
VS Code configuration
{
  "servers": {
    "the-grate-guys-mcp": {
      "type": "http",
      "url": "https://thegrateguys.com/mcp"
    }
  }
}

Gemini CLI

Run this once. It writes .gemini/settings.json in the current project; pass --scope user for ~/.gemini/settings.json.
Gemini CLI configuration
gemini mcp add --transport http the-grate-guys-mcp https://thegrateguys.com/mcp

Claude Desktop

Open Claude Settings > Connectors > Add custom connector, enter this server URL and enable it for the conversation. This is a manual remote-connector handoff, not a desktop JSON configuration.
Claude Desktop configuration
https://thegrateguys.com/mcp

Windsurf

Merge this into ~/.codeium/windsurf/mcp_config.json, then refresh MCP in Cascade. Windsurf remote servers use serverUrl, not url.
Windsurf configuration
{
  "mcpServers": {
    "the-grate-guys-mcp": {
      "serverUrl": "https://thegrateguys.com/mcp"
    }
  }
}

Let your agent find its tools

Find servers like The Grate Guys MCP from your agent. Add Koskamo once to search the index for endpoints, access requirements, and client setup. Public discovery needs no key.

Frequently asked questions

Can agents calculate safe load and deflection for steel bar grating spans?
Yes, the server includes tools like `bar_grating_load_calculator` and `aluminum_stainless_bar_grating_load_calculator` to compute load spans and deflection for various grating types.
Does the server check Ontario Building Code compliance for guardrails and stairs?
Yes, tools such as `guard_and_railing_code_checker_ontario` and `steel_stair_calculator_ontario` are available to verify compliance with Ontario Building Code requirements for these structures.
What are the prerequisites for using the galvanizing coating thickness calculator?
While connection requires no sign-in, individual tools may need a vendor account, credentials, or permissions. Users must check the documented prerequisites for `galvanizing_coating_thickness_calculator` before use.
Can agents compute theoretical weights of carbon steel shapes?
Yes, the `steel_weight_calculator` tool allows agents to compute the theoretical weight of various carbon steel shapes for fabrication projects.

Do you run The Grate Guys MCP?

Prove ownership with a DNS record, a well-known file, or your Official MCP Registry entry, and your edits publish immediately. Proofs are re-checked weekly; admins can still hide or remove a listing.

Claim this listing