The Grate Guys MCP
An official MCP server providing engineering calculators and code checkers for metal grating, drainage, and fabrication. It allows agents to compute load spans, check building code compliance for guardrails and stairs, calculate steel weights, and determine galvanizing requirements for custom metalwork projects.
Endpoint and access
No sign-in to connect and list tools. Individual tools may still need a vendor account, credentials, or permissions; check the documented prerequisites.
https://thegrateguys.com/mcpWhat its tools do
15 tools, grouped by the hints the server advertises. Hints are self-declared, not verified behavior.
Read-only (15)
bar_grating_load_calculatorbar_grating_load_tablesaluminum_stainless_bar_grating_load_calculatoraccessible_grating_opening_checkergalvanizing_coating_thickness_calculatorguard_and_railing_code_checker_ontariosteel_stair_calculator_ontariosteel_weight_calculatortrench_drain_grate_load_classbollard_spacing_and_footing_calculatorsteel_beam_lintel_span_checkcatch_basin_grate_and_frame_size_finderfence_and_gate_post_spacing_and_weighttrench_drain_flow_capacity_calculatorloading_dock_height_and_leveler_check
Checks and signals
Each line is separate evidence, not a trust score.
- Passed Endpoint answered the live check ·
- Passed Official MCP Registry namespace is tied to thegrateguys.com ·
- Passed Endpoint is on the registry namespace domain ·
- Uptime 100% over 90 days
- Availability 2 of 2 checks passed in 30 days
About The Grate Guys MCP
The Grate Guys server offers specialized utilities for metal grating, drainage, and fabrication engineering. It supports agents in performing structural calculations and verifying regulatory standards for industrial metalwork applications.
Key capabilities include determining safe load limits and deflection for steel bar grating, verifying Ontario Building Code adherence for guardrails and stairs, computing theoretical weights for carbon steel shapes, and establishing minimum galvanizing thickness per ASTM A123.
Accessing The Grate Guys requires no sign-in to list available tools. However, individual operations may require specific vendor accounts, credentials, or permissions. Users should review documented prerequisites for each tool before execution.
What you can do with it
- Calculate safe load and deflection for steel bar grating spans
- Check Ontario Building Code compliance for guardrails and stairs
- Compute theoretical weight of various carbon steel shapes
- Determine minimum galvanizing coating thickness per ASTM A123
Source and maintenance
Protocol and capabilities
- Server
- The Grate Guys 1.0.0
- MCP protocol negotiated in check
- 2025-11-25
- Tools
- 15 advertised
- Resources
- Not advertised
- Resource templates
- Not advertised
- Prompts
- Not advertised
{
"tools": {}
}Server-provided instructions
Untrusted server output shown for inspection. It is not Koskamo guidance and is excluded from knowledge search.
Tools
15 advertised
bar_grating_load_calculator
Finds the lightest welded steel bearing bar (19-W-4 or 15-W-4, smooth or serrated) that carries a clear span and load within a deflection limit.
{
"type": "object",
"properties": {
"load": {
"enum": [
"ped",
"uni",
"con"
],
"type": "string",
"default": "ped",
"description": "ped = pedestrian, 100 lb/sq ft with a 1/4 in deflection limit; uni = uniform load you give in value; con = concentrated load at mid-span you give in value."
},
"value": {
"type": "number",
"x-unit": "lb/sq ft or lb/ft",
"description": "The load to check when load is uni (lb/sq ft) or con (lb per ft of grating width). Required for uni and con."
},
"pattern": {
"enum": [
"19-w-4",
"15-w-4",
"both"
],
"type": "string",
"default": "19-w-4",
"description": "19-W-4 (1-3/16 in bar centres), 15-W-4 (15/16 in) or both."
},
"span_ft": {
"type": "number",
"x-unit": "ft",
"description": "Clear span in feet, measured in the direction of the bearing bars, 0.5 to 12. Give only one of span_ft, span_in, span_mm. Default 3 ft."
},
"span_in": {
"type": "number",
"x-unit": "in",
"description": "Clear span in inches (6 to 144)."
},
"span_mm": {
"type": "number",
"x-unit": "mm",
"description": "Clear span in millimetres (152 to 3658)."
},
"surface": {
"enum": [
"smooth",
"serrated"
],
"type": "string",
"default": "smooth",
"description": "Serrated bars are calculated 1/4 in shallower."
},
"area_sqft": {
"type": "number",
"x-unit": "sq ft",
"description": "Optional total grating area for an approximate total weight."
},
"deflection": {
"enum": [
"0.25",
"0.125",
"0.375",
"span240",
"span360",
"none"
],
"type": "string",
"x-unit": "in",
"default": "0.25",
"description": "Deflection limit in inches, span240 (span / 240), span360 (span / 360) or none (strength only). Ignored for ped."
}
},
"additionalProperties": false
}{
"title": "Steel bar grating load and span calculator",
"readOnlyHint": true
}bar_grating_load_tables
Looks up the safe uniform load (U), safe concentrated load (C), deflections and weight for welded steel bar grating by bearing bar size and span.
{
"type": "object",
"properties": {
"bar": {
"enum": [
"1x1/8",
"1x3/16",
"1-1/4x1/8",
"1-1/4x3/16",
"1-1/2x1/8",
"1-1/2x3/16",
"1-3/4x3/16",
"2x3/16",
"2-1/2x3/16"
],
"type": "string",
"description": "Optional bearing bar size, depth x thickness in inches, for example 1-1/4x3/16. Leave out for every bar."
},
"pattern": {
"enum": [
"19-w-4",
"15-w-4"
],
"type": "string",
"default": "19-w-4",
"description": "19-W-4 or 15-W-4 pattern."
},
"span_ft": {
"type": "number",
"x-unit": "ft",
"description": "Optional clear span in feet (1 to 12). Tabulated spans are 2 to 8 ft in 6 in steps. Leave out for every tabulated span."
},
"surface": {
"enum": [
"smooth",
"serrated"
],
"type": "string",
"default": "smooth",
"description": "Serrated bars act 1/4 in shallower."
}
},
"additionalProperties": false
}{
"title": "Bar grating load tables (19-W-4 and 15-W-4)",
"readOnlyHint": true
}aluminum_stainless_bar_grating_load_calculator
Safe load, deflection and the lightest bearing bar for aluminum 6063-T6 and stainless 304, 316, 304L and 316L bar grating at 1-3/16 in bar centres.
{
"type": "object",
"properties": {
"load": {
"enum": [
"ped",
"uni",
"con"
],
"type": "string",
"default": "ped",
"description": "ped = pedestrian, 100 lb/sq ft with a 1/4 in deflection limit; uni = uniform load you give in value; con = concentrated load at mid-span you give in value."
},
"value": {
"type": "number",
"x-unit": "lb/sq ft or lb/ft",
"description": "The load to check when load is uni (lb/sq ft) or con (lb per ft of grating width). Required for uni and con."
},
"span_in": {
"type": "number",
"x-unit": "in",
"description": "Clear span in inches, 24 to 108 (the range of the published tables). Give only one of span_in, span_mm. Default 36 in."
},
"span_mm": {
"type": "number",
"x-unit": "mm",
"description": "Clear span in millimetres, 610 to 2743."
},
"material": {
"enum": [
"al-6063",
"ss-304-316",
"ss-304l-316l"
],
"type": "string",
"default": "al-6063",
"description": "Aluminum 6063-T6, stainless 304 or 316, or stainless 304L or 316L."
},
"deflection": {
"enum": [
"0.25",
"0.125",
"0.375",
"span240",
"span360",
"none"
],
"type": "string",
"x-unit": "in",
"default": "0.25",
"description": "Deflection limit in inches, span240 (span / 240), span360 (span / 360) or none (strength only). Ignored for ped."
}
},
"additionalProperties": false
}{
"title": "Aluminum and stainless bar grating load calculator",
"readOnlyHint": true
}accessible_grating_opening_checker
Checks the clear opening between bearing bars against the Ontario Building Code 13 mm limit for barrier-free paths of travel, and the widest bar spacing that would pass.
{
"type": "object",
"properties": {
"pattern": {
"enum": [
"19-w-4",
"15-w-4",
"custom"
],
"type": "string",
"default": "19-w-4",
"description": "19-W-4 (1-3/16 in centres), 15-W-4 (15/16 in centres) or custom (give spacing_in)."
},
"spacing_in": {
"type": "number",
"x-unit": "in",
"description": "Bearing bar centre-to-centre spacing in inches. Required when pattern is custom."
},
"bar_thickness_in": {
"type": "number",
"x-unit": "in",
"default": 0.125,
"description": "Bearing bar thickness in inches, for example 0.125 (1/8), 0.1875 (3/16), 0.25 (1/4)."
}
},
"additionalProperties": false
}{
"title": "Accessible grating opening checker (13 mm rule)",
"readOnlyHint": true
}galvanizing_coating_thickness_calculator
Minimum average hot-dip galvanized coating grade by steel category and thickness, in mils, microns and ounces of zinc per square foot, with total zinc for a surface area.
{
"type": "object",
"properties": {
"category": {
"enum": [
"shapes",
"strip",
"plate",
"pipe",
"wire",
"rebar"
],
"type": "string",
"default": "shapes",
"description": "shapes = structural shapes (angles, channels, beams); strip = strip and bar; plate; pipe = pipe and tubing; wire; rebar = reinforcing bar."
},
"area_sqft": {
"type": "number",
"x-unit": "sq ft",
"description": "Optional surface area to be coated, for the minimum zinc weight."
},
"thickness_in": {
"type": "number",
"x-unit": "in",
"description": "Steel thickness in inches. Give only one of thickness_in, thickness_mm. Default 0.1875 in."
},
"thickness_mm": {
"type": "number",
"x-unit": "mm",
"description": "Steel thickness in millimetres."
}
},
"additionalProperties": false
}{
"title": "Galvanizing coating thickness calculator (ASTM A123)",
"readOnlyHint": true
}guard_and_railing_code_checker_ontario
Whether a guard is required, its minimum height, opening limit, climbing rule and design loads under the Ontario Building Code Part 9 and Part 3 for a described situation.
{
"type": "object",
"properties": {
"use": {
"enum": [
"normal",
"equip"
],
"type": "string",
"default": "normal",
"description": "normal = ordinary guard; equip = access way to an equipment platform where many people are improbable."
},
"drop": {
"type": "number",
"x-unit": "per the unit parameter",
"default": 900,
"description": "Drop to the adjacent surface within 1.2 m (4 ft). A guard is required above 600 mm (23.6 in)."
},
"unit": {
"enum": [
"mm",
"in"
],
"type": "string",
"default": "mm",
"description": "Unit of every length below."
},
"opening": {
"type": "number",
"x-unit": "per the unit parameter",
"default": 95,
"description": "Largest opening: the widest sphere that passes through the guard."
},
"location": {
"enum": [
"dwelling",
"exthouse",
"part9",
"exit3"
],
"type": "string",
"default": "part9",
"description": "dwelling = within a dwelling unit; exthouse = exterior serving one dwelling unit; part9 = other Part 9 building; exit3 = required exit in a larger (Part 3) building."
},
"industrial": {
"type": "boolean",
"default": false,
"description": "Industrial occupancy."
},
"loading_dock": {
"type": "boolean",
"default": false,
"description": "Loading dock."
},
"planned_height": {
"type": "number",
"x-unit": "per the unit parameter",
"default": 1070,
"description": "Guard height you plan."
},
"stair_triangle": {
"type": "number",
"x-unit": "per the unit parameter",
"description": "Optional stair triangle gap, widest sphere."
},
"maintenance_only": {
"type": "boolean",
"default": false,
"description": "Access for maintenance only."
},
"height_above_grade": {
"type": "number",
"x-unit": "per the unit parameter",
"default": 900,
"description": "Walking surface height above grade."
}
},
"additionalProperties": false
}{
"title": "Ontario guard and railing code checker",
"readOnlyHint": true
}steel_stair_calculator_ontario
Allowed riser counts, riser height, tread run, flights, width, headroom and handrail height for a total rise under Ontario Building Code Part 9.
{
"type": "object",
"properties": {
"run": {
"type": "number",
"x-unit": "per the unit parameter",
"default": 280,
"description": "Tread run you want (nosing to nosing)."
},
"unit": {
"enum": [
"mm",
"in"
],
"type": "string",
"default": "mm",
"description": "Unit of every length below."
},
"width": {
"type": "number",
"x-unit": "per the unit parameter",
"default": 1000,
"description": "Clear stair width."
},
"handrail": {
"type": "number",
"x-unit": "per the unit parameter",
"default": 920,
"description": "Handrail height above the nosing line."
},
"headroom": {
"type": "number",
"x-unit": "per the unit parameter",
"default": 2100,
"description": "Clear headroom over the stair."
},
"location": {
"enum": [
"dwelling",
"exitres",
"exitother"
],
"type": "string",
"default": "exitother",
"description": "dwelling = within a dwelling unit or house; exitres = exit or public stair, residential building; exitother = exit or public stair, other building."
},
"stair_type": {
"enum": [
"private",
"public",
"service"
],
"type": "string",
"default": "public",
"description": "private = inside or outside a house or single dwelling unit; public = every other stair; service = serves service rooms only (Table 9.8.4.1.)."
},
"total_rise": {
"type": "number",
"x-unit": "per the unit parameter",
"default": 2800,
"description": "Total rise, finished floor to finished floor. At least 375 mm (14.8 in)."
}
},
"additionalProperties": false
}{
"title": "Ontario steel stair calculator",
"readOnlyHint": true
}steel_weight_calculator
Theoretical weight of carbon steel plate, flat bar, round bar, square bar, angle, square or rectangular tube and round pipe, in pounds and kilograms.
{
"type": "object",
"properties": {
"side": {
"type": "number",
"x-unit": "per the unit parameter",
"description": "Side: square bar."
},
"unit": {
"enum": [
"in",
"mm"
],
"type": "string",
"default": "in",
"description": "Unit of every size and the length."
},
"wall": {
"type": "number",
"x-unit": "per the unit parameter",
"description": "Wall thickness: tube and pipe."
},
"leg_a": {
"type": "number",
"x-unit": "per the unit parameter",
"description": "Leg A: angle."
},
"leg_b": {
"type": "number",
"x-unit": "per the unit parameter",
"description": "Leg B: angle."
},
"shape": {
"enum": [
"plate",
"flat",
"round",
"square",
"angle",
"tube",
"pipe"
],
"type": "string",
"default": "plate",
"description": "plate or sheet, flat bar, round bar, square bar, angle, square or rectangular tube, round pipe or tube."
},
"width": {
"type": "number",
"x-unit": "per the unit parameter",
"description": "Width: plate, flat bar, tube."
},
"height": {
"type": "number",
"x-unit": "per the unit parameter",
"description": "Height: rectangular tube."
},
"length": {
"type": "number",
"x-unit": "per the unit parameter",
"default": 12,
"description": "Length of one piece."
},
"diameter": {
"type": "number",
"x-unit": "per the unit parameter",
"description": "Diameter: round bar."
},
"quantity": {
"type": "number",
"default": 1,
"description": "Number of pieces."
},
"thickness": {
"type": "number",
"x-unit": "per the unit parameter",
"description": "Thickness: plate, flat bar, angle."
},
"outside_diameter": {
"type": "number",
"x-unit": "per the unit parameter",
"description": "Outside diameter: pipe."
}
},
"additionalProperties": false
}{
"title": "Steel weight calculator",
"readOnlyHint": true
}trench_drain_grate_load_class
The EN 1433 load class, A 15 to F 900, and its test load in kN for where a trench drain goes and what drives or rolls over it.
{
"type": "object",
"properties": {
"application": {
"enum": [
"footpath",
"domestic-driveway",
"private-road",
"public-space",
"car-park",
"retail-parking",
"petrol-forecourt",
"vans-light-trucks",
"public-road-trucks",
"logistics-bus",
"industrial-forklift",
"port-airport"
],
"type": "string",
"default": "domestic-driveway",
"description": "footpath = Footpath, patio, pool deck or cycle path; domestic-driveway = Domestic driveway (cars and light vans); private-road = Private road or slow residential lane; public-space = Public space or plaza with light vehicles; car-park = Car park (slow, light vehicles); retail-parking = Supermarket or retail parking lot; petrol-forecourt = Petrol station forecourt (fuel delivery trucks cross it); vans-light-trucks = Vans and light trucks up to 7.5 t; public-road-trucks = Public road, carriageway or commercial driveway with trucks; logistics-bus = Logistics area or bus station; industrial-forklift = Industrial yard or loading dock apron with forklifts; port-airport = Container terminal, port, airport or aircraft apron. If more than one applies, pick the heaviest."
}
},
"additionalProperties": false
}{
"title": "Trench drain grate load class picker (EN 1433)",
"readOnlyHint": true
}bollard_spacing_and_footing_calculator
Counts the bollards for a frontage and clear gap, checks the gap against vehicle and wheelchair guidance, gives typical footing and concrete for a standard (not crash rated) steel pipe bollard, and explains crash ratings.
{
"type": "object",
"properties": {
"ends": {
"enum": [
"between-fixed-points",
"bollard-at-each-end"
],
"type": "string",
"default": "between-fixed-points",
"description": "between-fixed-points: the frontage runs between two fixed obstructions such as walls, and the end gaps also count. bollard-at-each-end: the frontage is measured outside edge to outside edge of the end bollards."
},
"pipe": {
"enum": [
"4",
"6",
"8",
"10"
],
"type": "string",
"default": "6",
"description": "Nominal pipe size in inches (outside diameter 4.5, 6.625, 8.625, 10.75 in). Footing figures exist for 6 and 8."
},
"rating": {
"enum": [
"M30",
"M40",
"M50",
"P1",
"P2",
"P3",
"P4",
"K4",
"K8",
"K12",
"PAS68",
"IWA14"
],
"type": "string",
"description": "Optional crash rating to explain."
},
"height_in": {
"type": "number",
"x-unit": "in",
"default": 36,
"description": "Pipe height above grade in inches (24 to 60). 36 in is the guide figure."
},
"frontage_m": {
"type": "number",
"x-unit": "m",
"description": "Frontage to protect in metres."
},
"max_gap_in": {
"type": "number",
"x-unit": "in",
"description": "Largest clear gap between bollards you will allow, in inches (12 to 120). Give only one of max_gap_in, max_gap_mm. Default 48 in."
},
"max_gap_mm": {
"type": "number",
"x-unit": "mm",
"description": "Largest clear gap in millimetres."
},
"frontage_ft": {
"type": "number",
"x-unit": "ft",
"description": "Frontage to protect in feet (1 to 1,000). Give only one of frontage_ft, frontage_m. Default 40 ft."
},
"footing_shape": {
"enum": [
"square",
"round"
],
"type": "string",
"default": "square",
"description": "Footing shape."
},
"footing_width_in": {
"type": "number",
"x-unit": "in",
"default": 18,
"description": "Footing width in inches (12 to 48). 18 in square is the figure for a 6 in pipe in the cited guide."
}
},
"additionalProperties": false
}{
"title": "Bollard planner: spacing, count and footing",
"readOnlyHint": true
}steel_beam_lintel_span_check
The steel angle lintel or steel beam that the 2024 Ontario Building Code Part 9 tables list for an opening width in a brick or stone veneer wall or a masonry wall, with the 150 mm bearing rule. Not a stamped design.
{
"type": "object",
"properties": {
"wall": {
"enum": [
"veneer-brick-70",
"veneer-brick-90",
"veneer-stone-100",
"solid-brick-100",
"solid-stone-150"
],
"type": "string",
"default": "veneer-brick-90",
"description": "veneer-brick-70 = 70 mm brick veneer; veneer-brick-90 = 90 mm brick veneer; veneer-stone-100 = 100 mm stone veneer; solid-brick-100 = masonry wall, 100 mm brick (Table 9.20.5.2.-A, exterior angle); solid-stone-150 = masonry wall, 100 mm brick plus 50 mm stone facing (Table 9.20.5.2.-A, exterior angle)."
},
"member": {
"enum": [
"angle",
"beam"
],
"type": "string",
"default": "angle",
"description": "angle = steel angle lintel; beam = steel beam supporting masonry veneer and a wood stud wall (veneer walls only)."
},
"bearing_mm": {
"type": "number",
"x-unit": "mm",
"description": "Optional: the bearing length you have at each end, to check against the 150 mm minimum."
},
"opening_ft": {
"type": "number",
"x-unit": "ft",
"description": "Clear opening width in feet."
},
"opening_mm": {
"type": "number",
"x-unit": "mm",
"description": "Clear opening width in millimetres (300 to 6,000). Give only one of opening_mm, opening_ft. Default 2,000 mm."
}
},
"additionalProperties": false
}{
"title": "Steel lintel and beam span check (2024 Ontario Building Code Part 9)",
"readOnlyHint": true
}catch_basin_grate_and_frame_size_finder
Names the Ontario Provincial Standard Drawing for a catch basin inlet type, checks the grate bearing on the frame ledge against the NAAMM minimum, gives the range of bearing bar lengths that sit on the ledge, and lists the EN 1433 load class for the traffic.
{
"type": "object",
"properties": {
"inlet": {
"enum": [
"square-flat",
"square-dished",
"square-v",
"birdcage",
"overflow-perforated",
"raised-circular",
"curb-inlet",
"curb-overflow"
],
"type": "string",
"default": "square-flat",
"description": "square-flat = OPSD 400.020, General purpose frame and flat grate; square-dished = OPSD 400.010, Dished grate with an overflow path; square-v = OPSD 400.030, V grate; birdcage = OPSD 400.120, Birdcage grate; overflow-perforated = OPSD 400.110, Overflow flat grate with perforated openings; raised-circular = OPSD 400.070, Raised frame with a round grate; curb-inlet = OPSD 400.081, Curb inlet outside the roadway; curb-overflow = OPSD 400.090, Curb inlet overflow."
},
"seat_mm": {
"type": "number",
"x-unit": "mm",
"default": 40,
"description": "Width of the ledge the grate sits on, each end, in millimetres (0 to 300)."
},
"span_in": {
"type": "number",
"x-unit": "in",
"description": "The same clear opening in inches."
},
"span_mm": {
"type": "number",
"x-unit": "mm",
"description": "Clear opening between the frame ledges, in the direction the bearing bars will run, 100 to 3,000 mm. Give only one of span_mm, span_in. Default 500 mm."
},
"traffic": {
"enum": [
"pedestrian",
"private-light",
"public-light",
"road-commercial",
"industrial",
"extreme"
],
"type": "string",
"default": "private-light",
"description": "pedestrian = A 15; private-light = B 125; public-light = C 250; road-commercial = D 400; industrial = E 600; extreme = F 900."
},
"bar_depth_in": {
"type": "number",
"x-unit": "in",
"default": 1.25,
"description": "Depth of the grate bearing bars in inches (0.75 to 6), for example 1.25 or 2.5."
}
},
"additionalProperties": false
}{
"title": "Catch basin grate and frame finder (OPSD type, bearing check, load class)",
"readOnlyHint": true
}fence_and_gate_post_spacing_and_weight
Post count and spacing for a chain link or ornamental steel fence run, chain link footing depth and gate post size, and the weight and hinge loads of an ornamental steel gate leaf.
{
"type": "object",
"properties": {
"panel": {
"enum": [
"chain-link",
"ornamental"
],
"type": "string",
"default": "ornamental",
"description": "chain-link (line posts 10 ft apart at most) or ornamental steel tubular pickets (8 ft, 96 in on center)."
},
"gap_in": {
"type": "number",
"x-unit": "in",
"default": 3.5,
"description": "Ornamental gate: largest gap between pickets in inches (4 in is the most the maker chart allows)."
},
"leaves": {
"enum": [
"1",
"2"
],
"type": "string",
"default": 1,
"description": "Single or double leaf gate."
},
"run_ft": {
"type": "number",
"x-unit": "ft",
"default": 40,
"description": "Length of the fence run in feet, not counting the gate (3 to 2,000)."
},
"gate_ft": {
"type": "number",
"x-unit": "ft",
"default": 0,
"description": "Gate opening in feet, 0 for no gate (0 to 24). The gate sits at the end of the run."
},
"tube_in": {
"type": "number",
"x-unit": "in",
"default": 1.5,
"description": "Ornamental gate frame: square tube outside size in inches."
},
"wall_in": {
"type": "number",
"x-unit": "in",
"default": 0.12,
"description": "Ornamental gate frame: tube wall in inches (0.12 is about 11 gauge)."
},
"height_ft": {
"type": "number",
"x-unit": "ft",
"default": 6,
"description": "Fence and gate height in feet (3 to 12)."
},
"mid_rails": {
"type": "number",
"default": 1,
"description": "Ornamental gate: rails between the top and bottom rail."
},
"picket_in": {
"type": "number",
"x-unit": "in",
"default": 0.5,
"description": "Ornamental gate: square picket size in inches."
},
"post_od_in": {
"type": "number",
"x-unit": "in",
"description": "Chain link line post outside diameter in inches, to get the footing diameter."
},
"hinge_spacing_in": {
"type": "number",
"x-unit": "in",
"description": "Distance between the two hinges in inches. Default: gate height less 24 in."
}
},
"additionalProperties": false
}{
"title": "Fence and gate post spacing, post count and gate weight",
"readOnlyHint": true
}trench_drain_flow_capacity_calculator
The flow a trench drain has to handle from a paved area (rational method with Toronto City rainfall rates from Environment and Climate Change Canada) and the flow the channel carries (Manning), with the narrowest channel that works.
{
"type": "object",
"properties": {
"c": {
"type": "number",
"description": "Optional runoff coefficient C (above 0, up to 1) to use instead of the top of the range for the surface."
},
"lining": {
"enum": [
"concrete-trowel",
"concrete-float",
"concrete-unfinished",
"plastic-smooth"
],
"type": "string",
"default": "concrete-trowel",
"description": "concrete-trowel = Concrete, trowel finish; concrete-float = Concrete, float finish; concrete-unfinished = Concrete, unfinished; plastic-smooth = Smooth plastic."
},
"period": {
"enum": [
"2",
"5",
"10",
"25",
"50",
"100"
],
"type": "string",
"default": 10,
"description": "Return period in years."
},
"area_m2": {
"type": "number",
"x-unit": "m2",
"description": "Paved area draining to the trench in square metres (1 to 100,000). Give only one of area_m2, area_sqft. Default 500 m2."
},
"surface": {
"enum": [
"asphalt",
"concrete",
"brick",
"drive-walk",
"roof",
"lawn-heavy-flat"
],
"type": "string",
"default": "asphalt",
"description": "asphalt = Asphalt pavement; concrete = Concrete pavement; brick = Brick or interlocking paver; drive-walk = Driveway or walkway; roof = Roof; lawn-heavy-flat = Lawn, heavy soil, flat (2% or less). The top of the range for the surface is used unless c is given."
},
"depth_mm": {
"type": "number",
"x-unit": "mm",
"default": 150,
"description": "Water depth at the outlet end in millimetres (30 to 1,000)."
},
"duration": {
"enum": [
"5",
"10",
"15",
"30"
],
"type": "string",
"default": 10,
"description": "Storm duration in minutes, taken as the time of concentration."
},
"width_mm": {
"type": "number",
"x-unit": "mm",
"default": 150,
"description": "Channel internal width in millimetres (50 to 1,000)."
},
"area_sqft": {
"type": "number",
"x-unit": "sq ft",
"description": "The same area in square feet."
},
"slope_pct": {
"type": "number",
"x-unit": "%",
"default": 1,
"description": "Channel slope in percent (0.05 to 20)."
}
},
"additionalProperties": false
}{
"title": "Trench drain flow and channel capacity calculator",
"readOnlyHint": true
}loading_dock_height_and_leveler_check
The grade a dock leveler works at between the lowest and highest truck bed you serve, against the 10% (electric) and 15% (gas or diesel) limits, the shortest standard leveler length that fits, and whether two makers published working ranges cover it.
{
"type": "object",
"properties": {
"equipment": {
"enum": [
"electric",
"combustion"
],
"type": "string",
"default": "electric",
"description": "electric = pallet, skid or electric fork trucks (10% grade limit); combustion = gas or diesel fork trucks (15%)."
},
"bed_low_in": {
"type": "number",
"x-unit": "in",
"default": 44,
"description": "Lowest truck bed height you serve, in inches (20 to 80). Vehicle beds range from 30 to 62 in."
},
"leveler_ft": {
"enum": [
"6",
"8",
"10",
"12"
],
"type": "string",
"default": 8,
"description": "Leveler length in feet. Standard lengths are 6, 8, 10 and 12 ft."
},
"bed_high_in": {
"type": "number",
"x-unit": "in",
"default": 52,
"description": "Highest truck bed height you serve, in inches."
},
"dock_height_in": {
"type": "number",
"x-unit": "in",
"default": 48,
"description": "Dock floor height above the driveway in inches (20 to 80). The most common dock height is 48 to 52 in."
}
},
"additionalProperties": false
}{
"title": "Loading dock height and leveler check",
"readOnlyHint": true
}Prompts
Not advertised
Resources
Not advertised
90-day uptime
A lightweight connection check about every six hours, sampled on hosts with many listings. It shows the server answered, not that its tools work.
- 2026-11-17: 2 of 2 checks answered
- 2026-11-18: 5 of 5 checks answered
- 2026-11-19: 4 of 4 checks answered
- 2026-11-20: 3 of 3 checks answered
- 2026-11-21: 4 of 4 checks answered
- 2026-11-22: 4 of 4 checks answered
- 2026-11-23: 3 of 3 checks answered
- 2026-11-24: 4 of 4 checks answered
- 2026-11-25: 4 of 4 checks answered
- 2026-11-26: 4 of 4 checks answered
- 2026-11-27: 4 of 4 checks answered
- 2026-11-28: 3 of 3 checks answered
- 2026-11-29: 2 of 2 checks answered
30-day availability
Aggregated from read-only remote checks; this is not a tool-execution or security guarantee.
- Successful checks
- 2 of 2 (100%)
- Average latency
- 539 ms
- 95th percentile latency
- 774 ms
Maintenance history
Public check and source-refresh events. Editorial and ownership records remain private.
- · probe · passed · 800 ms · 15 tool(s)
- · probe · passed · 277 ms · metadata changed · 15 tool(s)
Connect from your client
Each snippet registers the same endpoint; pick the client you use.
Claude Code
claude mcp add --transport http the-grate-guys-mcp https://thegrateguys.com/mcpCodex
codex mcp add the-grate-guys-mcp --url https://thegrateguys.com/mcpCursor
{
"mcpServers": {
"the-grate-guys-mcp": {
"url": "https://thegrateguys.com/mcp"
}
}
}Cline
{
"mcpServers": {
"the-grate-guys-mcp": {
"type": "streamableHttp",
"url": "https://thegrateguys.com/mcp",
"disabled": false
}
}
}VS Code
{
"servers": {
"the-grate-guys-mcp": {
"type": "http",
"url": "https://thegrateguys.com/mcp"
}
}
}Gemini CLI
gemini mcp add --transport http the-grate-guys-mcp https://thegrateguys.com/mcpClaude Desktop
https://thegrateguys.com/mcpWindsurf
{
"mcpServers": {
"the-grate-guys-mcp": {
"serverUrl": "https://thegrateguys.com/mcp"
}
}
}Let your agent find its tools
Find servers like The Grate Guys MCP from your agent. Add Koskamo once to search the index for endpoints, access requirements, and client setup. Public discovery needs no key.
Other developer tools servers
Frequently asked questions
- Can agents calculate safe load and deflection for steel bar grating spans?
- Yes, the server includes tools like `bar_grating_load_calculator` and `aluminum_stainless_bar_grating_load_calculator` to compute load spans and deflection for various grating types.
- Does the server check Ontario Building Code compliance for guardrails and stairs?
- Yes, tools such as `guard_and_railing_code_checker_ontario` and `steel_stair_calculator_ontario` are available to verify compliance with Ontario Building Code requirements for these structures.
- What are the prerequisites for using the galvanizing coating thickness calculator?
- While connection requires no sign-in, individual tools may need a vendor account, credentials, or permissions. Users must check the documented prerequisites for `galvanizing_coating_thickness_calculator` before use.
- Can agents compute theoretical weights of carbon steel shapes?
- Yes, the `steel_weight_calculator` tool allows agents to compute the theoretical weight of various carbon steel shapes for fabrication projects.
Do you run The Grate Guys MCP?