Koskamo

Spark Pack MCP

A remote MCP server providing tools for UK electricians, including cable sizing, voltage drop calculations, Part P notification checks, certificate validation (EIC, Minor Works, EICR), and G98/G99 grid connection rules for solar, EV, and heat pumps.

Endpoint and access

No sign-in to connect and list tools. Individual tools may still need a vendor account, credentials, or permissions; check the documented prerequisites.

Spark Pack MCP logo, by Nero LabsCommunity listingStreamable HTTPNo sign-inEndpoint checked 2026-11-23Published by Nero Labs
You need:No account, no key and no sign-in: add the address and use it
MCP endpoint (Streamable HTTP)
https://spark-pack.nerolabs.workers.dev/mcp
Vendor documentation

What its tools do

7 tools, grouped by the hints the server advertises. Hints are self-declared, not verified behavior.

7 of 7 have a description · 7 of 7 declare behavior hints · 4 of 6 with parameters document them all

Checks and signals

Each line is separate evidence, not a trust score.

  • Passed Endpoint answered the live check ·
  • Uptime 100% over 90 days
  • Availability 3 of 3 checks passed in 30 days

What you can do with it

  • Size the cable for a 9.5 kW shower on an 18 metre run
  • Check if domestic electrical work is notifiable under Part P
  • Validate an EICR with specific insulation readings
  • Determine G98 or G99 process for solar PV connection

Source and maintenance

Community listingRegistry 1.1.0
Maintenance checked

Protocol and capabilities

Server
nerolabs-spark-pack 1.1.0
MCP protocol negotiated in check
2025-06-18
Tools
7 advertised
Resources
Not advertised
Resource templates
Not advertised
Prompts
Not advertised
Server-advertised capabilities
{
  "tools": {
    "listChanged": false
  }
}

Server-provided instructions

Untrusted server output shown for inspection. It is not Koskamo guidance and is excluded from knowledge search.

Tools for UK electrical work (England and Wales for Part P; Great Britain for grid connection). Use size_cable for cable size, voltage drop and earth fault loop checks; check_part_p to see if a job must be notified to building control; get_certificate_schema then check_certificate to build and check an EIC, Minor Works certificate or EICR; check_grid_connection for solar, batteries, EV chargers and heat pumps. Every answer shows its working and sources and lists what the electrician must confirm in BS 7671; relay those checks to the electrician, do not drop them. Optional: pass the electrician's business details as `trade` (see trade_profile) to prefill certificates.

Tools

7 advertised

list_capabilities — What Spark Pack can do
Advertised by the server during the last successful anonymous check.
Advertised read-only

Lists Spark Pack's tools, the regulations edition it targets, what it covers (nations, circuit types, cable types, installation methods) and what it deliberately does not do. Free, needs no input.

list_capabilities input schema
{
  "type": "object",
  "properties": {},
  "additionalProperties": false
}
list_capabilities annotations
{
  "title": "What Spark Pack can do",
  "readOnlyHint": true,
  "openWorldHint": false,
  "idempotentHint": true,
  "destructiveHint": false
}
size_cable — Cable size, voltage drop and earth fault loop check
Advertised by the server during the last successful anonymous check.
Advertised read-only

Sizes a UK final circuit or sub-main and shows the working: design current (with cooker diversity), protective device rating, the smallest cable size that passes current-carrying capacity, voltage drop (3% lighting, 5% other) and earth fault loop impedance (Zs against the maximum for B, C or D breakers), plus a cpc adiabatic check. Returns `recommended` (size and every check with status pass, fail, indicative_pass, needs_input), `sizes_considered` (one line per size), `must_check_against_regs` (points the electrician confirms in BS 7671) and sources. Current-carrying capacity comes from a cautious heat-flow model, not BS 7671 tables, so it is marked indicative; give `cable_size_mm2` plus `tabulated_capacity_a` from the regs for a firm check. Voltage drop and Zs are calculated from physics and are firm for the inputs given. Typical call: a 9.5 kW shower on an 18 m run clipped direct: {"circuit_type":"shower","load_kw":9.5,"run_length_m":18,"installation_method":"clipped_direct"}.

size_cable input schema
{
  "type": "object",
  "required": [
    "circuit_type",
    "run_length_m",
    "installation_method"
  ],
  "properties": {
    "cores": {
      "enum": [
        2,
        3,
        4
      ],
      "type": "number",
      "description": "SWA only: number of cores. Defaults to 3 single phase (spare core as cpc) or 4 three phase. With 2 the armour is the cpc: give armour_resistance_mohm_per_m."
    },
    "trade": {
      "type": "object",
      "properties": {
        "town": {
          "type": "string"
        },
        "email": {
          "type": "string"
        },
        "phone": {
          "type": "string"
        },
        "address": {
          "type": "string",
          "description": "Business address for the certificate contractor block."
        },
        "postcode": {
          "type": "string"
        },
        "categories": {
          "type": "array",
          "items": {
            "type": "string"
          },
          "description": "Trades offered. Defaults to [\"electrical\"]."
        },
        "company_name": {
          "type": "string",
          "description": "Registered company name, if a limited company."
        },
        "display_name": {
          "type": "string",
          "description": "Trading name shown to customers, for example \"Bright Sparks Electrical\"."
        },
        "licence_body": {
          "enum": [
            "niceic",
            "napit",
            "elecsa",
            "stroma",
            "certsure",
            "benchmark",
            "other",
            "none"
          ],
          "type": "string",
          "description": "Competent person scheme the business is registered with."
        },
        "company_number": {
          "type": "string",
          "description": "Companies House number, for example 12345678 or SC123456."
        },
        "licence_number": {
          "type": "string",
          "description": "Scheme registration or enrolment number."
        }
      },
      "description": "Optional. The electrician's own business details (Nero Trade Profile v1). Used to prefill certificate contractor fields and to give a stable nero_trade_ref. Not stored by Spark Pack.",
      "additionalProperties": false
    },
    "phases": {
      "enum": [
        1,
        3
      ],
      "type": "number",
      "description": "Defaults to 1."
    },
    "load_kw": {
      "type": "number",
      "description": "Load in kW (for example 9.5 for a shower, 7.4 for a 32 A EV charger). Give this or design_current_a."
    },
    "ze_ohms": {
      "type": "number",
      "description": "Measured external earth fault loop impedance Ze, ohms. Without it the typical network maximum is used (0.35 TN-C-S, 0.8 TN-S)."
    },
    "earthing": {
      "enum": [
        "tn_c_s",
        "tn_s",
        "tt"
      ],
      "type": "string",
      "description": "Supply earthing. Defaults to tn_c_s (PME)."
    },
    "ambient_c": {
      "type": "number",
      "description": "Ambient temperature, C. Defaults to 30 in air, 20 in the ground."
    },
    "cable_type": {
      "enum": [
        "twin_and_earth",
        "swa_xlpe",
        "swa_pvc",
        "singles_in_conduit"
      ],
      "type": "string",
      "description": "Defaults to twin_and_earth, or swa_xlpe for buried runs and sub-mains."
    },
    "circuit_type": {
      "enum": [
        "shower",
        "cooker",
        "ev_charger",
        "ring_final",
        "radial_sockets",
        "lighting",
        "immersion",
        "heat_pump",
        "sub_main",
        "other"
      ],
      "type": "string",
      "description": "What the circuit feeds. ring_final and radial_sockets can be sized without a load (the device rating is used)."
    },
    "cpc_size_mm2": {
      "type": "number",
      "description": "Override the circuit protective conductor size (twin and earth sizes are known)."
    },
    "power_factor": {
      "type": "number",
      "description": "Defaults to 1 (resistive loads, EV chargers). Use about 0.95 for heat pumps or mixed sub-main loads."
    },
    "run_length_m": {
      "type": "number",
      "description": "Cable length from the board to the furthest point, metres. For a ring, the total ring length."
    },
    "cable_size_mm2": {
      "type": "number",
      "description": "Check this specific size as well as finding the smallest that passes."
    },
    "grouping_factor": {
      "type": "number",
      "description": "Grouping factor Cg from the regs for the arrangement, if known. Without it Spark Pack uses a cautious estimate."
    },
    "design_current_a": {
      "type": "number",
      "description": "Design current Ib in amps, if already known. Overrides load_kw."
    },
    "grouped_circuits": {
      "type": "number",
      "description": "Number of circuits bunched together along the run, including this one. Defaults to 1."
    },
    "cooker_has_socket": {
      "type": "boolean",
      "description": "Cooker only: the cooker control unit has a socket outlet."
    },
    "protective_device": {
      "type": "object",
      "properties": {
        "kind": {
          "enum": [
            "mcb",
            "rcbo",
            "rewireable_fuse"
          ],
          "type": "string",
          "description": "Defaults to mcb."
        },
        "curve": {
          "enum": [
            "B",
            "C",
            "D"
          ],
          "type": "string",
          "description": "Breaker type, defaults to B."
        },
        "rating_a": {
          "type": "number",
          "description": "Device rating In, amps."
        }
      },
      "description": "The breaker or fuse. Leave rating_a out to let Spark Pack choose the smallest standard rating at or above the design current.",
      "additionalProperties": false
    },
    "installation_method": {
      "enum": [
        "clipped_direct",
        "in_conduit_or_trunking_on_wall",
        "in_conduit_in_insulated_wall",
        "touching_insulation_one_side",
        "surrounded_by_insulation",
        "above_ceiling_insulation_under_100mm",
        "buried_direct",
        "in_duct_underground"
      ],
      "type": "string",
      "description": "How the cable is run. clipped_direct: Clipped direct to a wall or surface, in free air; in_conduit_or_trunking_on_wall: In conduit or trunking fixed on a wall; in_conduit_in_insulated_wall: In conduit in a thermally insulated wall; touching_insulation_one_side: In a stud wall or ceiling void, touching thermal insulation on one side; surrounded_by_insulation: Totally surrounded by thermal insulation (deep loft insulation, insulated stud wall); above_ceiling_insulation_under_100mm: Clipped to a joist above a plasterboard ceiling, insulation 100 mm or less, cable not covered; buried_direct: Buried direct in the ground (about 0.7 m deep); in_duct_underground: In a duct in the ground (about 0.7 m deep). If the run passes through several, give the worst one (usually insulation)."
    },
    "tabulated_capacity_a": {
      "type": "number",
      "description": "Tabulated current-carrying capacity It for cable_size_mm2 and this method, read from BS 7671 Appendix 4 by the electrician. Makes the capacity check firm."
    },
    "apply_cooker_diversity": {
      "type": "boolean",
      "description": "Cooker only: apply the usual domestic cooker diversity (default true)."
    },
    "soil_thermal_resistivity": {
      "type": "number",
      "description": "Buried runs: soil thermal resistivity K.m/W, defaults to 2.5 (cautious)."
    },
    "armour_resistance_mohm_per_m": {
      "type": "number",
      "description": "SWA armour resistance from the cable datasheet, milliohms per metre, when the armour is the cpc."
    },
    "upstream_voltage_drop_percent": {
      "type": "number",
      "description": "Voltage drop already used upstream (for a circuit fed from a sub-board), percent."
    }
  },
  "additionalProperties": false
}
size_cable annotations
{
  "title": "Cable size, voltage drop and earth fault loop check",
  "readOnlyHint": true,
  "openWorldHint": false,
  "idempotentHint": true,
  "destructiveHint": false
}
check_part_p — Is this job notifiable under Part P?
Advertised by the server during the last successful anonymous check.
Advertised read-only

Answers whether domestic electrical work in England or Wales must be notified to building control under Part P of the Building Regulations, with the reason and what to do next (self-certify through a competent person scheme within 30 days, or tell building control before starting). England and Wales differ: in Wales kitchens and outdoor areas are still special locations. Returns `notifiable` (true or false), `answer`, `reason`, `what_to_do`, `must_check` and sources. Scotland and Northern Ireland return not_covered. Example: adding a socket in a kitchen in England: {"nation":"england","work":"add_to_or_alter_existing_circuit","locations":["kitchen"]}.

check_part_p input schema
{
  "type": "object",
  "required": [
    "nation",
    "work"
  ],
  "properties": {
    "work": {
      "enum": [
        "new_circuit",
        "consumer_unit_replacement",
        "add_to_or_alter_existing_circuit",
        "replace_like_for_like",
        "repair_or_maintenance",
        "connect_equipment_to_existing_point"
      ],
      "type": "string",
      "description": "The kind of work. Pick the most significant if the job has several parts (a new circuit outranks everything)."
    },
    "trade": {
      "type": "object",
      "properties": {
        "town": {
          "type": "string"
        },
        "email": {
          "type": "string"
        },
        "phone": {
          "type": "string"
        },
        "address": {
          "type": "string",
          "description": "Business address for the certificate contractor block."
        },
        "postcode": {
          "type": "string"
        },
        "categories": {
          "type": "array",
          "items": {
            "type": "string"
          },
          "description": "Trades offered. Defaults to [\"electrical\"]."
        },
        "company_name": {
          "type": "string",
          "description": "Registered company name, if a limited company."
        },
        "display_name": {
          "type": "string",
          "description": "Trading name shown to customers, for example \"Bright Sparks Electrical\"."
        },
        "licence_body": {
          "enum": [
            "niceic",
            "napit",
            "elecsa",
            "stroma",
            "certsure",
            "benchmark",
            "other",
            "none"
          ],
          "type": "string",
          "description": "Competent person scheme the business is registered with."
        },
        "company_number": {
          "type": "string",
          "description": "Companies House number, for example 12345678 or SC123456."
        },
        "licence_number": {
          "type": "string",
          "description": "Scheme registration or enrolment number."
        }
      },
      "description": "Optional. The electrician's own business details (Nero Trade Profile v1). Used to prefill certificate contractor fields and to give a stable nero_trade_ref. Not stored by Spark Pack.",
      "additionalProperties": false
    },
    "nation": {
      "enum": [
        "england",
        "wales",
        "scotland",
        "northern_ireland"
      ],
      "type": "string",
      "description": "Where the property is."
    },
    "building": {
      "enum": [
        "dwelling",
        "outbuilding_or_garden_of_dwelling",
        "common_parts_of_flats",
        "commercial_or_industrial"
      ],
      "type": "string",
      "description": "Defaults to dwelling."
    },
    "locations": {
      "type": "array",
      "items": {
        "enum": [
          "bath_or_shower_zone",
          "swimming_or_paddling_pool",
          "sauna_heater_room",
          "kitchen",
          "outdoors",
          "elsewhere"
        ],
        "type": "string"
      },
      "description": "Where the work is. bath_or_shower_zone means within the zoned space around a bath or shower. Defaults to [\"elsewhere\"]."
    },
    "registered_with_competent_person_scheme": {
      "type": "boolean",
      "description": "Whether the electrician is registered with a scheme such as NICEIC or NAPIT. Changes the next steps."
    }
  },
  "additionalProperties": false
}
check_part_p annotations
{
  "title": "Is this job notifiable under Part P?",
  "readOnlyHint": true,
  "openWorldHint": false,
  "idempotentHint": true,
  "destructiveHint": false
}
get_certificate_schema — Certificate fields as a JSON schema
Advertised by the server during the last successful anonymous check.
Advertised read-only

Returns the fields an Electrical Installation Certificate (eic), Minor Electrical Installation Works Certificate (minor_works) or Electrical Installation Condition Report (eicr) needs, as a JSON Schema the assistant fills from the job notes and test readings (spark-pack-certs-1.0 (for BS 7671:2018+A4:2026 certificates)). Includes which certificate to use when, and the contractor block prefilled from `trade` if given. check_certificate checks the filled object. Field names are Spark Pack's own; the electrician transfers the values to the official form in their scheme portal or software.

get_certificate_schema input schema
{
  "type": "object",
  "required": [
    "certificate"
  ],
  "properties": {
    "trade": {
      "type": "object",
      "properties": {
        "town": {
          "type": "string"
        },
        "email": {
          "type": "string"
        },
        "phone": {
          "type": "string"
        },
        "address": {
          "type": "string",
          "description": "Business address for the certificate contractor block."
        },
        "postcode": {
          "type": "string"
        },
        "categories": {
          "type": "array",
          "items": {
            "type": "string"
          },
          "description": "Trades offered. Defaults to [\"electrical\"]."
        },
        "company_name": {
          "type": "string",
          "description": "Registered company name, if a limited company."
        },
        "display_name": {
          "type": "string",
          "description": "Trading name shown to customers, for example \"Bright Sparks Electrical\"."
        },
        "licence_body": {
          "enum": [
            "niceic",
            "napit",
            "elecsa",
            "stroma",
            "certsure",
            "benchmark",
            "other",
            "none"
          ],
          "type": "string",
          "description": "Competent person scheme the business is registered with."
        },
        "company_number": {
          "type": "string",
          "description": "Companies House number, for example 12345678 or SC123456."
        },
        "licence_number": {
          "type": "string",
          "description": "Scheme registration or enrolment number."
        }
      },
      "description": "Optional. The electrician's own business details (Nero Trade Profile v1). Used to prefill certificate contractor fields and to give a stable nero_trade_ref. Not stored by Spark Pack.",
      "additionalProperties": false
    },
    "certificate": {
      "enum": [
        "eic",
        "minor_works",
        "eicr"
      ],
      "type": "string",
      "description": "eic for new circuits, consumer units and new installations; minor_works for additions or alterations to one existing circuit; eicr for periodic inspection reports."
    }
  },
  "additionalProperties": false
}
get_certificate_schema annotations
{
  "title": "Certificate fields as a JSON schema",
  "readOnlyHint": true,
  "openWorldHint": false,
  "idempotentHint": true,
  "destructiveHint": false
}
check_certificate — Check a filled certificate
Advertised by the server during the last successful anonymous check.
Advertised read-only

Checks a filled EIC, Minor Works certificate or EICR (shape from get_certificate_schema) and returns `ready_to_transfer`, every missing required field by path, errors (readings that fail: insulation resistance under 1 megohm at 500 V, measured Zs above the maximum for the breaker, RCD trip times too slow, wrong polarity, an EICR marked satisfactory with a C1 or C2) and warnings (Zs above 80% of maximum, mismatched ring readings, low insulation resistance). Contractor fields left blank are filled from `trade`. Returns the (prefilled) data back.

check_certificate input schema
{
  "type": "object",
  "required": [
    "certificate",
    "data"
  ],
  "properties": {
    "data": {
      "type": "object",
      "description": "The certificate object, shaped like the JSON Schema from get_certificate_schema."
    },
    "trade": {
      "type": "object",
      "properties": {
        "town": {
          "type": "string"
        },
        "email": {
          "type": "string"
        },
        "phone": {
          "type": "string"
        },
        "address": {
          "type": "string",
          "description": "Business address for the certificate contractor block."
        },
        "postcode": {
          "type": "string"
        },
        "categories": {
          "type": "array",
          "items": {
            "type": "string"
          },
          "description": "Trades offered. Defaults to [\"electrical\"]."
        },
        "company_name": {
          "type": "string",
          "description": "Registered company name, if a limited company."
        },
        "display_name": {
          "type": "string",
          "description": "Trading name shown to customers, for example \"Bright Sparks Electrical\"."
        },
        "licence_body": {
          "enum": [
            "niceic",
            "napit",
            "elecsa",
            "stroma",
            "certsure",
            "benchmark",
            "other",
            "none"
          ],
          "type": "string",
          "description": "Competent person scheme the business is registered with."
        },
        "company_number": {
          "type": "string",
          "description": "Companies House number, for example 12345678 or SC123456."
        },
        "licence_number": {
          "type": "string",
          "description": "Scheme registration or enrolment number."
        }
      },
      "description": "Optional. The electrician's own business details (Nero Trade Profile v1). Used to prefill certificate contractor fields and to give a stable nero_trade_ref. Not stored by Spark Pack.",
      "additionalProperties": false
    },
    "certificate": {
      "enum": [
        "eic",
        "minor_works",
        "eicr"
      ],
      "type": "string"
    }
  },
  "additionalProperties": false
}
check_certificate annotations
{
  "title": "Check a filled certificate",
  "readOnlyHint": true,
  "openWorldHint": false,
  "idempotentHint": true,
  "destructiveHint": false
}
check_grid_connection — G98, G99 or EV and heat pump notification?
Advertised by the server during the last successful anonymous check.
Advertised read-only

For solar PV, batteries, V2G chargers, EV chargers and heat pumps in Great Britain: says which network operator process applies and when. Generation: G98 (fully type tested, 16 A / 3.68 kW per phase or less: install, then notify within 28 days) or G99 (apply and wait for acceptance before installing), counting existing generation and battery inverters. Demand: the ENA EV charge point and heat pump form (connect and notify within 28 days if every criterion is met, otherwise apply first), with each criterion marked true, false or null (not yet known). Returns `generation`, `demand`, `facts_to_put_on_the_form` (prefilled from inputs and `trade`), `missing_facts` and sources. Example: 5 kW solar plus a 5 kW battery inverter on single phase: {"supply_phases":1,"new_equipment":[{"type":"solar_pv","rating_kw":5,"type_tested":true},{"type":"battery","rating_kw":5,"type_tested":true}]}.

check_grid_connection input schema
{
  "type": "object",
  "required": [
    "new_equipment"
  ],
  "properties": {
    "mpan": {
      "type": "string",
      "description": "Meter point administration number (the supply number on the bill)."
    },
    "trade": {
      "type": "object",
      "properties": {
        "town": {
          "type": "string"
        },
        "email": {
          "type": "string"
        },
        "phone": {
          "type": "string"
        },
        "address": {
          "type": "string",
          "description": "Business address for the certificate contractor block."
        },
        "postcode": {
          "type": "string"
        },
        "categories": {
          "type": "array",
          "items": {
            "type": "string"
          },
          "description": "Trades offered. Defaults to [\"electrical\"]."
        },
        "company_name": {
          "type": "string",
          "description": "Registered company name, if a limited company."
        },
        "display_name": {
          "type": "string",
          "description": "Trading name shown to customers, for example \"Bright Sparks Electrical\"."
        },
        "licence_body": {
          "enum": [
            "niceic",
            "napit",
            "elecsa",
            "stroma",
            "certsure",
            "benchmark",
            "other",
            "none"
          ],
          "type": "string",
          "description": "Competent person scheme the business is registered with."
        },
        "company_number": {
          "type": "string",
          "description": "Companies House number, for example 12345678 or SC123456."
        },
        "licence_number": {
          "type": "string",
          "description": "Scheme registration or enrolment number."
        }
      },
      "description": "Optional. The electrician's own business details (Nero Trade Profile v1). Used to prefill certificate contractor fields and to give a stable nero_trade_ref. Not stored by Spark Pack.",
      "additionalProperties": false
    },
    "nation": {
      "enum": [
        "great_britain",
        "northern_ireland"
      ],
      "type": "string",
      "description": "Defaults to great_britain."
    },
    "metered": {
      "type": "boolean",
      "description": "The supply is metered (defaults to unknown)."
    },
    "earthing": {
      "type": "string",
      "description": "Supply earthing, for example TN-C-S."
    },
    "ct_metered": {
      "type": "boolean"
    },
    "new_equipment": {
      "type": "array",
      "items": {
        "type": "object",
        "required": [
          "type",
          "rating_kw"
        ],
        "properties": {
          "type": {
            "enum": [
              "solar_pv",
              "battery",
              "v2g_charger",
              "ev_charger",
              "heat_pump",
              "wind",
              "other_generation"
            ],
            "type": "string"
          },
          "model": {
            "type": "string"
          },
          "rating_kw": {
            "type": "number",
            "description": "AC rating in kW: the inverter rating for PV and batteries, the charge rate for EV chargers, the maximum electrical input for heat pumps."
          },
          "type_tested": {
            "type": "boolean",
            "description": "Fully type tested and on the ENA Type Test Verification Report Register."
          },
          "manufacturer": {
            "type": "string"
          },
          "phase_connection": {
            "enum": [
              "single",
              "three"
            ],
            "type": "string",
            "description": "Defaults to single."
          },
          "connect_and_notify_listed": {
            "type": "boolean",
            "description": "Heat pumps: the model is marked Connect and Notify in the ENA heat pump database."
          }
        },
        "additionalProperties": false
      },
      "description": "Equipment being installed."
    },
    "site_postcode": {
      "type": "string"
    },
    "supply_phases": {
      "enum": [
        1,
        3
      ],
      "type": "number",
      "description": "Defaults to 1."
    },
    "looped_service": {
      "type": "boolean",
      "description": "The supply is looped with a neighbour."
    },
    "export_limit_kw": {
      "type": "number",
      "description": "Export limit if an export limiting scheme (G100) is fitted."
    },
    "cut_out_rating_a": {
      "type": "number",
      "description": "Network cut-out fuse rating, amps. Do not open the cut-out to find it."
    },
    "multiple_premises": {
      "type": "boolean",
      "description": "Part of several installations in a close area (housing development, street-wide scheme)."
    },
    "commissioning_date": {
      "type": "string",
      "description": "YYYY-MM-DD."
    },
    "existing_equipment": {
      "type": "array",
      "items": {
        "type": "object"
      },
      "description": "Generation, storage or chargers already at the premises, same shape as new_equipment."
    },
    "max_demand_after_a": {
      "type": "number",
      "description": "Premises maximum demand after the installation, amps per phase (from a load survey)."
    },
    "battery_storage_kwh": {
      "type": "number"
    },
    "load_limiting_device": {
      "type": "boolean",
      "description": "A load limiting or curtailment device keeps demand below the cut-out rating."
    },
    "service_equipment_ok": {
      "type": "boolean",
      "description": "No safety or adequacy concerns with the cut-out and service cable."
    },
    "heat_pump_single_controller": {
      "type": "boolean"
    }
  },
  "additionalProperties": false
}
check_grid_connection annotations
{
  "title": "G98, G99 or EV and heat pump notification?",
  "readOnlyHint": true,
  "openWorldHint": false,
  "idempotentHint": true,
  "destructiveHint": false
}
trade_profile — Check the electrician's business details
Advertised by the server during the last successful anonymous check.
Advertised read-only

Checks the electrician's own business details (Nero Trade Profile v1: trading name, Companies House number, competent person scheme and number, postcode, contact) and returns them cleaned, with a stable `nero_trade_ref` computed from the scheme registration or company number. The same object, given as `trade` to the other tools, prefills certificates and grid forms. Spark Pack stores nothing. The same profile and reference can later be used to sign the business into Nero Work, the agent job exchange for trades.

trade_profile input schema
{
  "type": "object",
  "required": [
    "trade"
  ],
  "properties": {
    "trade": {
      "type": "object",
      "properties": {
        "town": {
          "type": "string"
        },
        "email": {
          "type": "string"
        },
        "phone": {
          "type": "string"
        },
        "address": {
          "type": "string",
          "description": "Business address for the certificate contractor block."
        },
        "postcode": {
          "type": "string"
        },
        "categories": {
          "type": "array",
          "items": {
            "type": "string"
          },
          "description": "Trades offered. Defaults to [\"electrical\"]."
        },
        "company_name": {
          "type": "string",
          "description": "Registered company name, if a limited company."
        },
        "display_name": {
          "type": "string",
          "description": "Trading name shown to customers, for example \"Bright Sparks Electrical\"."
        },
        "licence_body": {
          "enum": [
            "niceic",
            "napit",
            "elecsa",
            "stroma",
            "certsure",
            "benchmark",
            "other",
            "none"
          ],
          "type": "string",
          "description": "Competent person scheme the business is registered with."
        },
        "company_number": {
          "type": "string",
          "description": "Companies House number, for example 12345678 or SC123456."
        },
        "licence_number": {
          "type": "string",
          "description": "Scheme registration or enrolment number."
        }
      },
      "description": "Optional. The electrician's own business details (Nero Trade Profile v1). Used to prefill certificate contractor fields and to give a stable nero_trade_ref. Not stored by Spark Pack.",
      "additionalProperties": false
    }
  },
  "additionalProperties": false
}
trade_profile annotations
{
  "title": "Check the electrician's business details",
  "readOnlyHint": true,
  "openWorldHint": false,
  "idempotentHint": true,
  "destructiveHint": false
}

Prompts

Not advertised

No prompt definitions available.

Resources

Not advertised

No resource definitions available.

90-day uptime

A lightweight connection check about every six hours, sampled on hosts with many listings. It shows the server answered, not that its tools work.

100% (37 of 37 checks answered)

  1. 2026-11-14: 1 of 1 checks answered
  2. 2026-11-15: 2 of 2 checks answered
  3. 2026-11-16: 4 of 4 checks answered
  4. 2026-11-17: 5 of 5 checks answered
  5. 2026-11-18: 5 of 5 checks answered
  6. 2026-11-19: 4 of 4 checks answered
  7. 2026-11-20: 3 of 3 checks answered
  8. 2026-11-21: 4 of 4 checks answered
  9. 2026-11-22: 4 of 4 checks answered
  10. 2026-11-23: 3 of 3 checks answered
  11. 2026-11-24: 2 of 2 checks answered

30-day availability

Aggregated from read-only remote checks; this is not a tool-execution or security guarantee.

Successful checks
3 of 3 (100%)
Average latency
497 ms
95th percentile latency
589 ms

Maintenance history

Public check and source-refresh events. Editorial and ownership records remain private.

  • · probe · passed · 490 ms · 7 tool(s)
  • · probe · passed · 402 ms · metadata changed · 7 tool(s)
  • · probe · passed · 600 ms · metadata changed · 7 tool(s)

Connect from your client

Each snippet registers the same endpoint; pick the client you use.

This server is operated by the named third party. Listing and endpoint checks are not an endorsement or a security audit. Review the operator's permissions, terms, and data handling before connecting. How listings are checked and corrected.

Claude Code

Run this once in a terminal. It registers the remote server. Use --scope project to write .mcp.json for the repo.
Claude Code configuration
claude mcp add --transport http spark-pack-mcp https://spark-pack.nerolabs.workers.dev/mcp

Codex

Run this once. Codex stores MCP servers in ~/.codex/config.toml (or .codex/config.toml in a trusted project).
Codex configuration
codex mcp add spark-pack-mcp --url https://spark-pack.nerolabs.workers.dev/mcp

Cursor

Merge this server into .cursor/mcp.json in your project, then enable spark-pack-mcp in your MCP settings.
Cursor configuration
{
  "mcpServers": {
    "spark-pack-mcp": {
      "url": "https://spark-pack.nerolabs.workers.dev/mcp"
    }
  }
}

Cline

Merge this into cline_mcp_settings.json (Cline → MCP Servers → Configure).
Cline configuration
{
  "mcpServers": {
    "spark-pack-mcp": {
      "type": "streamableHttp",
      "url": "https://spark-pack.nerolabs.workers.dev/mcp",
      "disabled": false
    }
  }
}

VS Code

Merge this server into .vscode/mcp.json. Use MCP: List Servers to start spark-pack-mcp and inspect its tools.
VS Code configuration
{
  "servers": {
    "spark-pack-mcp": {
      "type": "http",
      "url": "https://spark-pack.nerolabs.workers.dev/mcp"
    }
  }
}

Gemini CLI

Run this once. It writes .gemini/settings.json in the current project; pass --scope user for ~/.gemini/settings.json.
Gemini CLI configuration
gemini mcp add --transport http spark-pack-mcp https://spark-pack.nerolabs.workers.dev/mcp

Claude Desktop

Open Claude Settings > Connectors > Add custom connector, enter this server URL and enable it for the conversation. This is a manual remote-connector handoff, not a desktop JSON configuration.
Claude Desktop configuration
https://spark-pack.nerolabs.workers.dev/mcp

Windsurf

Merge this into ~/.codeium/windsurf/mcp_config.json, then refresh MCP in Cascade. Windsurf remote servers use serverUrl, not url.
Windsurf configuration
{
  "mcpServers": {
    "spark-pack-mcp": {
      "serverUrl": "https://spark-pack.nerolabs.workers.dev/mcp"
    }
  }
}

Let your agent find its tools

Find servers like Spark Pack MCP from your agent. Add Koskamo once to search the index for endpoints, access requirements, and client setup. Public discovery needs no key.