Koskamo

Site Pack MCP

A remote MCP server providing UK builders with AI-assisted checks for permitted development status, Building Regulations notifiability, Party Wall Act notice dates, CDM 2015 duties, material quantity estimates, and structural emergency triage.

Endpoint and access

No sign-in to connect and list tools. Individual tools may still need a vendor account, credentials, or permissions; check the documented prerequisites.

Site Pack MCP logo, by Nero LabsCommunity listingStreamable HTTPNo sign-inEndpoint checked 2026-11-23Published by Nero Labs
MCP endpoint (Streamable HTTP)
https://site-pack.nerolabs.workers.dev/mcp
Vendor documentation

What its tools do

8 tools, grouped by the hints the server advertises. Hints are self-declared, not verified behavior.

8 of 8 have a description · 8 of 8 declare behavior hints · 2 of 7 with parameters document them all

Checks and signals

Each line is separate evidence, not a trust score.

  • Passed Endpoint answered the live check ·
  • Uptime 100% over 90 days
  • Availability 3 of 3 checks passed in 30 days

About Site Pack MCP

Site Pack MCP is a developer tool operated by Nero Labs that provides AI-assisted checks for UK construction projects. It supports tasks such as determining permitted development status, assessing Building Regulations notifiability, calculating Party Wall Act notice dates, identifying CDM 2015 duties, estimating material quantities, and performing structural emergency triage.

The server connects via a Streamable HTTP endpoint. No sign-in is required to connect to the server or list available tools. However, individual tools may still require a vendor account, credentials, or specific permissions. Users must check the documented prerequisites for each specific task before execution.

The tool list includes cdm_duties, check_building_regs, check_permitted_development, estimate_materials, list_capabilities, party_wall_notices, structural_triage, and trade_profile. This setup suits developers integrating UK regulatory and estimation checks into their agents.

What you can do with it

  • Check if a rear extension needs planning permission
  • Determine Building Regulations route and applicable Parts
  • Calculate Party Wall notice dates and required notices
  • Estimate bricks, blocks, and mortar quantities

Source and maintenance

Community listingRegistry 1.1.0
Maintenance checked

Protocol and capabilities

Server
nerolabs-site-pack 1.1.0
MCP protocol negotiated in check
2025-06-18
Tools
8 advertised
Resources
Not advertised
Resource templates
Not advertised
Prompts
Not advertised
Server-advertised capabilities
{
  "tools": {
    "listChanged": false
  }
}

Server-provided instructions

Untrusted server output shown for inspection. It is not Koskamo guidance and is excluded from knowledge search.

Tools for UK building work (extensions, lofts, renovations, repairs). Planning permitted development is England only; Building Regulations and the Party Wall Act cover England and Wales; CDM 2015 covers Great Britain. Use check_permitted_development before quoting an extension, loft, porch or outbuilding; check_building_regs for notification, route and Parts; party_wall_notices for notice type and dates from a start date or a serve date; cdm_duties for who holds CDM duties and whether an F10 is needed; estimate_materials for quantities; structural_triage when a customer reports a crack, sagging ceiling, bulging wall or storm damage (its urgency is Nero Work's emergency, soon or routine). Every answer shows its working and sources and lists what must be confirmed (must_confirm); relay those to the builder, do not drop them. If a check says needs_input, ask the builder for that detail and call again. Optional: pass the builder's business details as `trade` (see trade_profile).

Tools

8 advertised

list_capabilities — What Site Pack can do
Advertised by the server during the last successful anonymous check.
Advertised read-only

Lists Site Pack's tools, the date its rules were last checked, what it covers (nations, project types, work types) and what it deliberately does not do. Free, needs no input.

list_capabilities input schema
{
  "type": "object",
  "properties": {},
  "additionalProperties": false
}
list_capabilities annotations
{
  "title": "What Site Pack can do",
  "readOnlyHint": true,
  "openWorldHint": false,
  "idempotentHint": true,
  "destructiveHint": false
}
check_permitted_development — Planning: permitted development or not? (England)
Advertised by the server during the last successful anonymous check.
Advertised read-only

Checks a householder project in England against the permitted development limits in the GPDO 2015, Schedule 2, Part 1: single and multi storey rear extensions, side and wraparound extensions (Class A), loft dormers and hip to gable (Class B), rooflights (Class C), porches (Class D), outbuildings and garden rooms (Class E), and adding storeys (Class AA). Returns `verdict` (permitted_development, prior_approval_route, needs_planning_permission, needs_listed_building_consent, check_article_4_or_condition, needs_more_info, not_covered), `answer`, one line per limit in `checks` (status pass, fail or needs_input, with the limit and the rule's paragraph), the larger home extension prior approval route when a single storey rear extension is 3 to 6 m (attached) or 4 to 8 m (detached), flags for conservation areas, National Parks, National Landscapes, listed buildings and Article 4, `must_confirm` and sources. Example: 3.5 m single storey rear extension on a semi, 3.8 m high: {"project":"rear_extension_single_storey","house_type":"semi_detached","depth_m":3.5,"height_m":3.8,"eaves_height_m":2.8,"within_2m_of_boundary":true,"curtilage_coverage_percent":20,"materials_similar":true,"higher_than_existing_roof":false,"eaves_higher_than_existing":false,"beyond_principal_or_highway_side_elevation":false,"balcony_veranda_or_raised_platform":false}.

check_permitted_development input schema
{
  "type": "object",
  "required": [
    "project"
  ],
  "properties": {
    "trade": {
      "type": "object",
      "properties": {
        "town": {
          "type": "string"
        },
        "email": {
          "type": "string"
        },
        "phone": {
          "type": "string"
        },
        "address": {
          "type": "string",
          "description": "Business address."
        },
        "postcode": {
          "type": "string"
        },
        "categories": {
          "type": "array",
          "items": {
            "type": "string"
          },
          "description": "Trades offered. Defaults to [\"building\"]."
        },
        "company_name": {
          "type": "string",
          "description": "Registered company name, if a limited company."
        },
        "display_name": {
          "type": "string",
          "description": "Trading name shown to customers, for example \"Oakline Building Services\"."
        },
        "licence_body": {
          "enum": [
            "fmb",
            "trustmark",
            "chas",
            "constructionline",
            "safecontractor",
            "fensa",
            "certass",
            "hetas",
            "napit",
            "competent_roofer",
            "labc_partner",
            "other",
            "none"
          ],
          "type": "string",
          "description": "Trade body or competent person scheme the business is a member of (the one used for the reference)."
        },
        "company_number": {
          "type": "string",
          "description": "Companies House number, for example 12345678 or SC123456."
        },
        "licence_number": {
          "type": "string",
          "description": "Membership or registration number with that body."
        }
      },
      "description": "Optional. The builder's own business details (Nero Trade Profile v1). Used to prefill the contractor details in notices and CDM answers and to give a stable nero_trade_ref. Not stored by Site Pack.",
      "additionalProperties": false
    },
    "nation": {
      "enum": [
        "england",
        "wales",
        "scotland",
        "northern_ireland"
      ],
      "type": "string",
      "description": "Defaults to england. Only england is checked; others return not_covered."
    },
    "depth_m": {
      "type": "number",
      "description": "Rear extensions: how far it projects beyond the rear wall of the ORIGINAL house, metres."
    },
    "project": {
      "enum": [
        "rear_extension_single_storey",
        "rear_extension_multi_storey",
        "side_extension",
        "wraparound_extension",
        "loft_conversion",
        "rooflight",
        "porch",
        "outbuilding",
        "upward_extension"
      ],
      "type": "string"
    },
    "storeys": {
      "type": "number",
      "description": "Storeys in the extension or outbuilding."
    },
    "width_m": {
      "type": "number",
      "description": "Side extensions: width of the extension."
    },
    "cladding": {
      "type": "boolean",
      "description": "Article 2(3) land: will the outside be clad in stone, render, pebble dash, timber, plastic or tiles?"
    },
    "height_m": {
      "type": "number",
      "description": "Highest point of the extension, porch or outbuilding above ground, metres."
    },
    "roof_type": {
      "enum": [
        "dual_pitched",
        "other"
      ],
      "type": "string",
      "description": "Outbuildings: dual pitched allows 4 m (if not within 2 m of a boundary)."
    },
    "house_type": {
      "enum": [
        "detached",
        "semi_detached",
        "terraced",
        "end_terrace"
      ],
      "type": "string",
      "description": "Needed for rear extensions (4 m detached, 3 m otherwise) and lofts (40 m3 terraced or end terrace, 50 m3 otherwise)."
    },
    "designations": {
      "type": "array",
      "items": {
        "enum": [
          "conservation_area",
          "national_park",
          "national_landscape",
          "world_heritage_site",
          "broads",
          "sssi",
          "listed_building",
          "article_4_direction",
          "pd_removed_by_condition"
        ],
        "type": "string"
      },
      "description": "Any that apply at the address. national_landscape is the new name for an AONB. Leave empty if none."
    },
    "hip_to_gable": {
      "type": "boolean",
      "description": "Lofts: is it a hip to gable (no eaves set back needed)?"
    },
    "protrusion_m": {
      "type": "number",
      "description": "Rooflights: how far it stands proud of the roof slope, metres."
    },
    "floor_area_m2": {
      "type": "number",
      "description": "Porches: external ground floor area. Outbuildings: footprint."
    },
    "property_kind": {
      "enum": [
        "house",
        "flat",
        "maisonette"
      ],
      "type": "string",
      "description": "Defaults to house. Flats and maisonettes have no householder permitted development."
    },
    "eaves_height_m": {
      "type": "number",
      "description": "Eaves height, metres."
    },
    "added_volume_m3": {
      "type": "number",
      "description": "Lofts: extra roof space volume including any earlier roof enlargements, m3."
    },
    "eaves_setback_m": {
      "type": "number",
      "description": "Lofts: dormer set back from the eaves along the slope, metres (at least 0.2)."
    },
    "materials_similar": {
      "type": "boolean",
      "description": "External materials look similar to the house."
    },
    "roof_pitch_matches": {
      "type": "boolean",
      "description": "Multi storey: roof pitch matches the house as far as practical."
    },
    "distance_from_house_m": {
      "type": "number",
      "description": "Outbuildings in National Parks, National Landscapes, the Broads or World Heritage Sites."
    },
    "within_2m_of_boundary": {
      "type": "boolean"
    },
    "original_house_width_m": {
      "type": "number",
      "description": "Side extensions: width of the original house."
    },
    "higher_than_existing_roof": {
      "type": "boolean"
    },
    "curtilage_coverage_percent": {
      "type": "number",
      "description": "After the work: ground covered by all buildings other than the original house, as a % of the plot excluding the original house footprint."
    },
    "eaves_higher_than_existing": {
      "type": "boolean"
    },
    "distance_to_rear_boundary_m": {
      "type": "number",
      "description": "Multi storey rear extensions: distance from the extension to the boundary opposite the rear wall."
    },
    "on_front_slope_facing_highway": {
      "type": "boolean",
      "description": "Lofts: does the dormer go on the front roof slope facing a road?"
    },
    "between_side_wall_and_boundary": {
      "type": "boolean",
      "description": "Outbuildings on Article 2(3) land."
    },
    "distance_to_highway_boundary_m": {
      "type": "number",
      "description": "Porches: distance to the boundary with a road or footway."
    },
    "forward_of_principal_elevation": {
      "type": "boolean",
      "description": "Outbuildings: in front of the house's front wall?"
    },
    "side_windows_obscure_and_fixed": {
      "type": "boolean",
      "description": "Upper floor or roof windows in a side wall are obscure glazed and non-opening below 1.7 m."
    },
    "balcony_veranda_or_raised_platform": {
      "type": "boolean",
      "description": "Includes a balcony, veranda, or a raised platform (decking) over 0.3 m high."
    },
    "used_for_sleeping_or_separate_home": {
      "type": "boolean"
    },
    "beyond_principal_or_highway_side_elevation": {
      "type": "boolean",
      "description": "Does it go forward of the front (principal) wall, or of a side wall facing a road?"
    }
  },
  "additionalProperties": false
}
check_permitted_development annotations
{
  "title": "Planning: permitted development or not? (England)",
  "readOnlyHint": true,
  "openWorldHint": false,
  "idempotentHint": true,
  "destructiveHint": false
}
check_building_regs — Building Regulations: notifiable, which route, which Parts? (England and Wales)
Advertised by the server during the last successful anonymous check.
Advertised read-only

For one or more kinds of building work in England or Wales: is it notifiable building work, exempt (small outbuildings, ground level conservatories and porches up to 30 m2), self-certifiable by a competent person scheme (FENSA, Certass, HETAS, OFTEC, CompetentRoofer), or must it go to the Building Safety Regulator (higher-risk buildings, England). Says whether a building notice is allowed or full plans are required (non-domestic, common parts of flats, within 3 m of a public sewer), and lists the Parts of Schedule 1 likely to apply with the reason for each (indicative). Returns `verdict`, `notifiable`, per-work reasons, routes, `parts_likely_to_apply`, `must_confirm` and sources. Example: {"work":["single_storey_extension","remove_load_bearing_wall"],"within_3m_of_public_sewer":false}.

check_building_regs input schema
{
  "type": "object",
  "required": [
    "work"
  ],
  "properties": {
    "work": {
      "type": "array",
      "items": {
        "enum": [
          "single_storey_extension",
          "multi_storey_extension",
          "loft_conversion",
          "garage_conversion",
          "remove_load_bearing_wall",
          "remove_non_load_bearing_wall",
          "new_or_replacement_windows_doors",
          "underpinning",
          "re_roof",
          "external_wall_insulation_or_render",
          "new_drainage",
          "new_bathroom_or_kitchen",
          "stove_or_flue",
          "conservatory",
          "porch",
          "outbuilding",
          "change_of_use",
          "new_dwelling",
          "like_for_like_repairs",
          "kitchen_or_bathroom_refit_no_new_services"
        ],
        "type": "string"
      },
      "description": "All the kinds of work in the job."
    },
    "trade": {
      "type": "object",
      "properties": {
        "town": {
          "type": "string"
        },
        "email": {
          "type": "string"
        },
        "phone": {
          "type": "string"
        },
        "address": {
          "type": "string",
          "description": "Business address."
        },
        "postcode": {
          "type": "string"
        },
        "categories": {
          "type": "array",
          "items": {
            "type": "string"
          },
          "description": "Trades offered. Defaults to [\"building\"]."
        },
        "company_name": {
          "type": "string",
          "description": "Registered company name, if a limited company."
        },
        "display_name": {
          "type": "string",
          "description": "Trading name shown to customers, for example \"Oakline Building Services\"."
        },
        "licence_body": {
          "enum": [
            "fmb",
            "trustmark",
            "chas",
            "constructionline",
            "safecontractor",
            "fensa",
            "certass",
            "hetas",
            "napit",
            "competent_roofer",
            "labc_partner",
            "other",
            "none"
          ],
          "type": "string",
          "description": "Trade body or competent person scheme the business is a member of (the one used for the reference)."
        },
        "company_number": {
          "type": "string",
          "description": "Companies House number, for example 12345678 or SC123456."
        },
        "licence_number": {
          "type": "string",
          "description": "Membership or registration number with that body."
        }
      },
      "description": "Optional. The builder's own business details (Nero Trade Profile v1). Used to prefill the contractor details in notices and CDM answers and to give a stable nero_trade_ref. Not stored by Site Pack.",
      "additionalProperties": false
    },
    "nation": {
      "enum": [
        "england",
        "wales",
        "scotland",
        "northern_ireland"
      ],
      "type": "string",
      "description": "Defaults to england. Scotland and Northern Ireland return not_covered."
    },
    "building_type": {
      "enum": [
        "house",
        "flat",
        "non_domestic"
      ],
      "type": "string",
      "description": "Defaults to house."
    },
    "floor_area_m2": {
      "type": "number",
      "description": "Outbuildings, conservatories and porches: internal floor area."
    },
    "higher_risk_building": {
      "type": "boolean",
      "description": "England: at least 18 m or 7 storeys with at least 2 homes (or a care home or hospital of that height)."
    },
    "area_renovated_percent": {
      "type": "number",
      "description": "Re-roofing, re-rendering, wall insulation: share of that roof or wall area being renovated, %."
    },
    "distance_to_boundary_m": {
      "type": "number",
      "description": "Outbuildings of 15 to 30 m2: distance to the nearest boundary."
    },
    "mainly_non_combustible": {
      "type": "boolean",
      "description": "Outbuildings of 15 to 30 m2: built mainly of non-combustible materials?"
    },
    "sleeping_accommodation": {
      "type": "boolean",
      "description": "Outbuildings: will anyone sleep in it?"
    },
    "competent_person_scheme": {
      "enum": [
        "fensa",
        "certass",
        "hetas",
        "oftec",
        "napit",
        "competent_roofer",
        "gas_safe",
        "niceic",
        "other"
      ],
      "type": "string",
      "description": "If the installer is a member of one (for windows, stoves, roofs)."
    },
    "heated_from_house_system": {
      "type": "boolean",
      "description": "Conservatories: heated by extending the house heating?"
    },
    "within_3m_of_public_sewer": {
      "type": "boolean"
    },
    "separated_by_external_doors": {
      "type": "boolean",
      "description": "Conservatories and porches: separated from the house by external quality walls, doors or windows?"
    }
  },
  "additionalProperties": false
}
check_building_regs annotations
{
  "title": "Building Regulations: notifiable, which route, which Parts?",
  "readOnlyHint": true,
  "openWorldHint": false,
  "idempotentHint": true,
  "destructiveHint": false
}
party_wall_notices — Party Wall Act notices and dates (England and Wales)
Advertised by the server during the last successful anonymous check.
Advertised read-only

Works out which notice the Party Wall etc. Act 1996 needs (line of junction, section 1; party structure, sections 2 and 3; adjacent excavation within 3 m or 6 m, section 6), and the dates: from `planned_start_date` the latest day to send it by the chosen method (by hand, first or second class post, email if agreed), or from `serve_date` the day it counts as served and the earliest start; plus the neighbour's 14 day reply deadline, when a dispute is deemed to arise, and when the notice lapses (12 months). Uses England and Wales bank holidays to 2028. Returns `notice`, `section`, `dates` (each as YYYY-MM-DD plus plain words), step by step `working`, what the notice must say, warnings and sources. Example: cutting a steel beam into a party wall, work to start 1 March 2027, posted first class: {"work":"insert_beam_or_dpc_into_party_wall","planned_start_date":"2027-03-01","serve_method":"first_class_post"}.

party_wall_notices input schema
{
  "type": "object",
  "required": [
    "work"
  ],
  "properties": {
    "work": {
      "enum": [
        "new_wall_on_boundary",
        "new_wall_up_to_boundary",
        "cut_into_party_wall",
        "insert_beam_or_dpc_into_party_wall",
        "raise_party_wall",
        "demolish_and_rebuild_party_wall",
        "underpin_party_wall",
        "remove_chimney_breast_on_party_wall",
        "excavate_near_neighbour"
      ],
      "type": "string"
    },
    "trade": {
      "type": "object",
      "properties": {
        "town": {
          "type": "string"
        },
        "email": {
          "type": "string"
        },
        "phone": {
          "type": "string"
        },
        "address": {
          "type": "string",
          "description": "Business address."
        },
        "postcode": {
          "type": "string"
        },
        "categories": {
          "type": "array",
          "items": {
            "type": "string"
          },
          "description": "Trades offered. Defaults to [\"building\"]."
        },
        "company_name": {
          "type": "string",
          "description": "Registered company name, if a limited company."
        },
        "display_name": {
          "type": "string",
          "description": "Trading name shown to customers, for example \"Oakline Building Services\"."
        },
        "licence_body": {
          "enum": [
            "fmb",
            "trustmark",
            "chas",
            "constructionline",
            "safecontractor",
            "fensa",
            "certass",
            "hetas",
            "napit",
            "competent_roofer",
            "labc_partner",
            "other",
            "none"
          ],
          "type": "string",
          "description": "Trade body or competent person scheme the business is a member of (the one used for the reference)."
        },
        "company_number": {
          "type": "string",
          "description": "Companies House number, for example 12345678 or SC123456."
        },
        "licence_number": {
          "type": "string",
          "description": "Membership or registration number with that body."
        }
      },
      "description": "Optional. The builder's own business details (Nero Trade Profile v1). Used to prefill the contractor details in notices and CDM answers and to give a stable nero_trade_ref. Not stored by Site Pack.",
      "additionalProperties": false
    },
    "nation": {
      "enum": [
        "england",
        "wales",
        "scotland",
        "northern_ireland"
      ],
      "type": "string",
      "description": "Defaults to england. The Act applies in England and Wales only."
    },
    "serve_date": {
      "type": "string",
      "description": "YYYY-MM-DD: the day the notice was or will be handed over, posted or emailed."
    },
    "serve_method": {
      "enum": [
        "by_hand",
        "first_class_post",
        "second_class_post",
        "email_agreed"
      ],
      "type": "string",
      "description": "Defaults to first_class_post."
    },
    "adjoining_owners": {
      "type": "number",
      "description": "How many adjoining owners (each gets their own notice). Defaults to 1."
    },
    "excavation_depth_m": {
      "type": "number",
      "description": "Excavations: depth of your excavation or foundation below ground."
    },
    "planned_start_date": {
      "type": "string",
      "description": "YYYY-MM-DD. Give this or serve_date (or both, to check the start is late enough)."
    },
    "neighbour_foundation_depth_m": {
      "type": "number",
      "description": "Excavations: depth of the neighbour's foundations, if known."
    },
    "distance_to_neighbour_building_m": {
      "type": "number",
      "description": "Excavations: horizontal distance from the excavation to the neighbour's building."
    },
    "neighbour_will_agree_earlier_start": {
      "type": "boolean"
    }
  },
  "additionalProperties": false
}
party_wall_notices annotations
{
  "title": "Party Wall Act notices and dates",
  "readOnlyHint": true,
  "openWorldHint": false,
  "idempotentHint": true,
  "destructiveHint": false
}
cdm_duties — CDM 2015 duties and HSE F10 notification
Advertised by the server during the last successful anonymous check.
Advertised read-only

For a construction project in Great Britain (domestic by default): who holds the client's duties (on a domestic job they pass to the contractor, the principal contractor, or the principal designer under a written agreement), which roles must be filled (principal designer and principal contractor when there is more than one contractor), the core duties (construction phase plan, welfare, induction, health and safety file), and whether the project must be notified to HSE on form F10 (longer than 30 working days with more than 20 workers at once, or over 500 person days), with the arithmetic shown. Returns `f10_notification_needed`, `f10_answer`, `client_duties_held_by`, `roles`, `duties`, `working`, `must_confirm` and sources. Example: an extension with 4 trades, 60 working days, peak 6 on site, average 3: {"contractors":4,"duration_working_days":60,"peak_workers_on_site":6,"average_workers_on_site":3}.

cdm_duties input schema
{
  "type": "object",
  "required": [
    "contractors"
  ],
  "properties": {
    "trade": {
      "type": "object",
      "properties": {
        "town": {
          "type": "string"
        },
        "email": {
          "type": "string"
        },
        "phone": {
          "type": "string"
        },
        "address": {
          "type": "string",
          "description": "Business address."
        },
        "postcode": {
          "type": "string"
        },
        "categories": {
          "type": "array",
          "items": {
            "type": "string"
          },
          "description": "Trades offered. Defaults to [\"building\"]."
        },
        "company_name": {
          "type": "string",
          "description": "Registered company name, if a limited company."
        },
        "display_name": {
          "type": "string",
          "description": "Trading name shown to customers, for example \"Oakline Building Services\"."
        },
        "licence_body": {
          "enum": [
            "fmb",
            "trustmark",
            "chas",
            "constructionline",
            "safecontractor",
            "fensa",
            "certass",
            "hetas",
            "napit",
            "competent_roofer",
            "labc_partner",
            "other",
            "none"
          ],
          "type": "string",
          "description": "Trade body or competent person scheme the business is a member of (the one used for the reference)."
        },
        "company_number": {
          "type": "string",
          "description": "Companies House number, for example 12345678 or SC123456."
        },
        "licence_number": {
          "type": "string",
          "description": "Membership or registration number with that body."
        }
      },
      "description": "Optional. The builder's own business details (Nero Trade Profile v1). Used to prefill the contractor details in notices and CDM answers and to give a stable nero_trade_ref. Not stored by Site Pack.",
      "additionalProperties": false
    },
    "client_type": {
      "enum": [
        "domestic",
        "commercial"
      ],
      "type": "string",
      "description": "Defaults to domestic (a homeowner having work done on their own home, not as a business)."
    },
    "contractors": {
      "type": "number",
      "description": "Firms and self-employed trades working on the project, including subcontractors. 1 if only you."
    },
    "person_days": {
      "type": "number",
      "description": "Total person days, if already known."
    },
    "peak_workers_on_site": {
      "type": "number",
      "description": "Most people working on site at the same time."
    },
    "duration_working_days": {
      "type": "number",
      "description": "Expected length of the construction work in working days."
    },
    "average_workers_on_site": {
      "type": "number",
      "description": "Typical number on site, used to estimate person days."
    },
    "designer_agreed_to_take_client_duties": {
      "type": "boolean",
      "description": "Domestic only: has the client a written agreement for the principal designer to take on the client duties?"
    }
  },
  "additionalProperties": false
}
cdm_duties annotations
{
  "title": "CDM 2015 duties and HSE F10 notification",
  "readOnlyHint": true,
  "openWorldHint": false,
  "idempotentHint": true,
  "destructiveHint": false
}
estimate_materials — Bricks, blocks, mortar, concrete and plasterboard quantities
Advertised by the server during the last successful anonymous check.
Advertised read-only

Works out quantities from dimensions, with the working: bricks (60 a m2 per half brick leaf), blocks (about 10 a m2), cavity walls with ties, mortar from wall volume minus unit volume, cement bags and sand tonnes for a chosen mix, concrete for strip foundations and slabs (ready mix order rounded up to 0.25 m3, or site mixed 1:2:4 materials), and plasterboard sheets by size. Openings are deducted. Waste allowances default to bricks and blocks 5%, mortar 10%, concrete 5%, plasterboard 10% and can be changed. Returns `order` (what to buy), per item `working`, totals before waste and notes. Example: a 6 m by 2.4 m cavity wall with a 1.2 m2 window, plus a 6 m strip foundation 0.6 m wide and 1 m deep: {"items":[{"kind":"cavity_wall","length_m":6,"height_m":2.4,"openings_m2":1.2},{"kind":"strip_foundation","length_m":6,"width_m":0.6,"depth_m":1}]}.

estimate_materials input schema
{
  "type": "object",
  "required": [
    "items"
  ],
  "properties": {
    "items": {
      "type": "array",
      "items": {
        "type": "object",
        "required": [
          "kind"
        ],
        "properties": {
          "kind": {
            "enum": [
              "brick_wall",
              "block_wall",
              "cavity_wall",
              "strip_foundation",
              "slab",
              "plasterboard"
            ],
            "type": "string"
          },
          "label": {
            "type": "string"
          },
          "sheet": {
            "enum": [
              "2400x1200",
              "2400x900",
              "1800x900",
              "3000x1200"
            ],
            "type": "string",
            "description": "Plasterboard sheet size. Defaults to 2400x1200."
          },
          "area_m2": {
            "type": "number"
          },
          "depth_m": {
            "type": "number",
            "description": "Strip foundation concrete depth."
          },
          "width_m": {
            "type": "number"
          },
          "height_m": {
            "type": "number"
          },
          "length_m": {
            "type": "number"
          },
          "thickness": {
            "enum": [
              "half_brick",
              "one_brick"
            ],
            "type": "string",
            "description": "Brick walls. Defaults to half_brick."
          },
          "openings_m2": {
            "type": "number",
            "description": "Walls: total area of windows and doors to deduct."
          },
          "thickness_m": {
            "type": "number",
            "description": "Slab thickness in metres (0.1 = 100 mm)."
          },
          "block_thickness_mm": {
            "type": "number",
            "description": "Block and cavity walls. Defaults to 100."
          }
        },
        "additionalProperties": false
      },
      "maxItems": 50
    },
    "trade": {
      "type": "object",
      "properties": {
        "town": {
          "type": "string"
        },
        "email": {
          "type": "string"
        },
        "phone": {
          "type": "string"
        },
        "address": {
          "type": "string",
          "description": "Business address."
        },
        "postcode": {
          "type": "string"
        },
        "categories": {
          "type": "array",
          "items": {
            "type": "string"
          },
          "description": "Trades offered. Defaults to [\"building\"]."
        },
        "company_name": {
          "type": "string",
          "description": "Registered company name, if a limited company."
        },
        "display_name": {
          "type": "string",
          "description": "Trading name shown to customers, for example \"Oakline Building Services\"."
        },
        "licence_body": {
          "enum": [
            "fmb",
            "trustmark",
            "chas",
            "constructionline",
            "safecontractor",
            "fensa",
            "certass",
            "hetas",
            "napit",
            "competent_roofer",
            "labc_partner",
            "other",
            "none"
          ],
          "type": "string",
          "description": "Trade body or competent person scheme the business is a member of (the one used for the reference)."
        },
        "company_number": {
          "type": "string",
          "description": "Companies House number, for example 12345678 or SC123456."
        },
        "licence_number": {
          "type": "string",
          "description": "Membership or registration number with that body."
        }
      },
      "description": "Optional. The builder's own business details (Nero Trade Profile v1). Used to prefill the contractor details in notices and CDM answers and to give a stable nero_trade_ref. Not stored by Site Pack.",
      "additionalProperties": false
    },
    "waste_percent": {
      "type": "object",
      "description": "Override any of: bricks, blocks, mortar, concrete, plasterboard (percent).",
      "additionalProperties": {
        "type": "number"
      }
    },
    "concrete_supply": {
      "enum": [
        "ready_mix",
        "site_mixed"
      ],
      "type": "string",
      "description": "Defaults to ready_mix."
    },
    "mortar_mix_sand_parts": {
      "type": "number",
      "description": "Sand parts to 1 cement, defaults to 5 (1:5). Use what the specification says."
    }
  },
  "additionalProperties": false
}
estimate_materials annotations
{
  "title": "Bricks, blocks, mortar, concrete and plasterboard quantities",
  "readOnlyHint": true,
  "openWorldHint": false,
  "idempotentHint": true,
  "destructiveHint": false
}
structural_triage — Structural worry: how urgent, and safe first steps
Advertised by the server during the last successful anonymous check.
Advertised read-only

First-response triage when a customer reports a crack, a bulging or leaning wall, a sagging or fallen ceiling, a collapse, storm damage to a roof or chimney, a fallen tree or vehicle impact, a sagging floor, problems after a wall was removed, or signs of subsidence. Cautious by design: any danger to people makes it an emergency. Returns `urgency` (emergency, soon or routine: the same three speeds Nero Work uses), reasons, `safe_first_steps`, who to call now (999, gas 0800 111 999, power 105, the council dangerous structures team, insurer, structural engineer), and the questions to ask if details are missing. Example: a ceiling bulging with water under a bathroom: {"problem":"ceiling_sagging_or_fallen","water_coming_in":true}.

structural_triage input schema
{
  "type": "object",
  "required": [
    "problem"
  ],
  "properties": {
    "trade": {
      "type": "object",
      "properties": {
        "town": {
          "type": "string"
        },
        "email": {
          "type": "string"
        },
        "phone": {
          "type": "string"
        },
        "address": {
          "type": "string",
          "description": "Business address."
        },
        "postcode": {
          "type": "string"
        },
        "categories": {
          "type": "array",
          "items": {
            "type": "string"
          },
          "description": "Trades offered. Defaults to [\"building\"]."
        },
        "company_name": {
          "type": "string",
          "description": "Registered company name, if a limited company."
        },
        "display_name": {
          "type": "string",
          "description": "Trading name shown to customers, for example \"Oakline Building Services\"."
        },
        "licence_body": {
          "enum": [
            "fmb",
            "trustmark",
            "chas",
            "constructionline",
            "safecontractor",
            "fensa",
            "certass",
            "hetas",
            "napit",
            "competent_roofer",
            "labc_partner",
            "other",
            "none"
          ],
          "type": "string",
          "description": "Trade body or competent person scheme the business is a member of (the one used for the reference)."
        },
        "company_number": {
          "type": "string",
          "description": "Companies House number, for example 12345678 or SC123456."
        },
        "licence_number": {
          "type": "string",
          "description": "Membership or registration number with that body."
        }
      },
      "description": "Optional. The builder's own business details (Nero Trade Profile v1). Used to prefill the contractor details in notices and CDM answers and to give a stable nero_trade_ref. Not stored by Site Pack.",
      "additionalProperties": false
    },
    "problem": {
      "enum": [
        "crack",
        "bulging_or_leaning_wall",
        "ceiling_sagging_or_fallen",
        "wall_collapsed_or_collapsing",
        "roof_storm_damage",
        "chimney_damaged",
        "fallen_tree_or_vehicle_impact",
        "floor_sagging_or_bouncy",
        "after_wall_removed",
        "subsidence_signs",
        "other"
      ],
      "type": "string"
    },
    "gas_smell": {
      "type": "boolean"
    },
    "crack_width_mm": {
      "type": "number",
      "description": "Cracks: widest point in mm."
    },
    "debris_falling": {
      "type": "boolean"
    },
    "water_coming_in": {
      "type": "boolean"
    },
    "near_road_or_footway": {
      "type": "boolean",
      "description": "Could it fall onto a road, footway or neighbour's property?"
    },
    "roof_open_to_weather": {
      "type": "boolean"
    },
    "water_near_electrics": {
      "type": "boolean"
    },
    "getting_worse_quickly": {
      "type": "boolean"
    },
    "rain_or_wind_forecast": {
      "type": "boolean"
    },
    "someone_injured_or_trapped": {
      "type": "boolean"
    },
    "new_cracks_or_sagging_above": {
      "type": "boolean",
      "description": "After a wall was removed or an impact: new cracks or sagging above?"
    },
    "doors_or_windows_sticking_recently": {
      "type": "boolean"
    },
    "crack_through_bricks_not_just_mortar": {
      "type": "boolean"
    }
  },
  "additionalProperties": false
}
structural_triage annotations
{
  "title": "Structural worry: how urgent, and safe first steps",
  "readOnlyHint": true,
  "openWorldHint": false,
  "idempotentHint": true,
  "destructiveHint": false
}
trade_profile — Check the builder's business details
Advertised by the server during the last successful anonymous check.
Advertised read-only

Checks the builder's own business details (Nero Trade Profile v1: trading name, Companies House number, trade body or scheme and membership number such as FMB or TrustMark, postcode, contact) and returns them cleaned, with a stable `nero_trade_ref` computed from the scheme membership or company number. The same object, given as `trade` to the other tools, prefills their answers. Site Pack stores nothing. The same profile and reference can later be used to sign the business into Nero Work, the agent job exchange for trades.

trade_profile input schema
{
  "type": "object",
  "required": [
    "trade"
  ],
  "properties": {
    "trade": {
      "type": "object",
      "properties": {
        "town": {
          "type": "string"
        },
        "email": {
          "type": "string"
        },
        "phone": {
          "type": "string"
        },
        "address": {
          "type": "string",
          "description": "Business address."
        },
        "postcode": {
          "type": "string"
        },
        "categories": {
          "type": "array",
          "items": {
            "type": "string"
          },
          "description": "Trades offered. Defaults to [\"building\"]."
        },
        "company_name": {
          "type": "string",
          "description": "Registered company name, if a limited company."
        },
        "display_name": {
          "type": "string",
          "description": "Trading name shown to customers, for example \"Oakline Building Services\"."
        },
        "licence_body": {
          "enum": [
            "fmb",
            "trustmark",
            "chas",
            "constructionline",
            "safecontractor",
            "fensa",
            "certass",
            "hetas",
            "napit",
            "competent_roofer",
            "labc_partner",
            "other",
            "none"
          ],
          "type": "string",
          "description": "Trade body or competent person scheme the business is a member of (the one used for the reference)."
        },
        "company_number": {
          "type": "string",
          "description": "Companies House number, for example 12345678 or SC123456."
        },
        "licence_number": {
          "type": "string",
          "description": "Membership or registration number with that body."
        }
      },
      "description": "Optional. The builder's own business details (Nero Trade Profile v1). Used to prefill the contractor details in notices and CDM answers and to give a stable nero_trade_ref. Not stored by Site Pack.",
      "additionalProperties": false
    }
  },
  "additionalProperties": false
}
trade_profile annotations
{
  "title": "Check the builder's business details",
  "readOnlyHint": true,
  "openWorldHint": false,
  "idempotentHint": true,
  "destructiveHint": false
}

Prompts

Not advertised

No prompt definitions available.

Resources

Not advertised

No resource definitions available.

90-day uptime

A lightweight connection check about every six hours, sampled on hosts with many listings. It shows the server answered, not that its tools work.

100% (53 of 53 checks answered)

  1. 2026-11-14: 1 of 1 checks answered
  2. 2026-11-15: 2 of 2 checks answered
  3. 2026-11-16: 4 of 4 checks answered
  4. 2026-11-17: 5 of 5 checks answered
  5. 2026-11-18: 5 of 5 checks answered
  6. 2026-11-19: 4 of 4 checks answered
  7. 2026-11-20: 3 of 3 checks answered
  8. 2026-11-21: 4 of 4 checks answered
  9. 2026-11-22: 4 of 4 checks answered
  10. 2026-11-23: 3 of 3 checks answered
  11. 2026-11-24: 4 of 4 checks answered
  12. 2026-11-25: 4 of 4 checks answered
  13. 2026-11-26: 4 of 4 checks answered
  14. 2026-11-27: 4 of 4 checks answered
  15. 2026-11-28: 2 of 2 checks answered

30-day availability

Aggregated from read-only remote checks; this is not a tool-execution or security guarantee.

Successful checks
3 of 3 (100%)
Average latency
509 ms
95th percentile latency
529 ms

Maintenance history

Public check and source-refresh events. Editorial and ownership records remain private.

  • · probe · passed · 509 ms · 8 tool(s)
  • · probe · passed · 486 ms · metadata changed · 8 tool(s)
  • · probe · passed · 531 ms · metadata changed · 8 tool(s)

Connect from your client

Each snippet registers the same endpoint; pick the client you use.

This server is operated by the named third party. Listing and endpoint checks are not an endorsement or a security audit. Review the operator's permissions, terms, and data handling before connecting. How listings are checked and corrected.

Claude Code

Run this once in a terminal. It registers the remote server. Use --scope project to write .mcp.json for the repo.
Claude Code configuration
claude mcp add --transport http site-pack-mcp https://site-pack.nerolabs.workers.dev/mcp

Codex

Run this once. Codex stores MCP servers in ~/.codex/config.toml (or .codex/config.toml in a trusted project).
Codex configuration
codex mcp add site-pack-mcp --url https://site-pack.nerolabs.workers.dev/mcp

Cursor

Merge this server into .cursor/mcp.json in your project, then enable site-pack-mcp in your MCP settings.
Cursor configuration
{
  "mcpServers": {
    "site-pack-mcp": {
      "url": "https://site-pack.nerolabs.workers.dev/mcp"
    }
  }
}

Cline

Merge this into cline_mcp_settings.json (Cline → MCP Servers → Configure).
Cline configuration
{
  "mcpServers": {
    "site-pack-mcp": {
      "type": "streamableHttp",
      "url": "https://site-pack.nerolabs.workers.dev/mcp",
      "disabled": false
    }
  }
}

VS Code

Merge this server into .vscode/mcp.json. Use MCP: List Servers to start site-pack-mcp and inspect its tools.
VS Code configuration
{
  "servers": {
    "site-pack-mcp": {
      "type": "http",
      "url": "https://site-pack.nerolabs.workers.dev/mcp"
    }
  }
}

Gemini CLI

Run this once. It writes .gemini/settings.json in the current project; pass --scope user for ~/.gemini/settings.json.
Gemini CLI configuration
gemini mcp add --transport http site-pack-mcp https://site-pack.nerolabs.workers.dev/mcp

Claude Desktop

Open Claude Settings > Connectors > Add custom connector, enter this server URL and enable it for the conversation. This is a manual remote-connector handoff, not a desktop JSON configuration.
Claude Desktop configuration
https://site-pack.nerolabs.workers.dev/mcp

Windsurf

Merge this into ~/.codeium/windsurf/mcp_config.json, then refresh MCP in Cascade. Windsurf remote servers use serverUrl, not url.
Windsurf configuration
{
  "mcpServers": {
    "site-pack-mcp": {
      "serverUrl": "https://site-pack.nerolabs.workers.dev/mcp"
    }
  }
}

Let your agent find its tools

Find servers like Site Pack MCP from your agent. Add Koskamo once to search the index for endpoints, access requirements, and client setup. Public discovery needs no key.

Frequently asked questions

Does connecting to Site Pack MCP require an account?
No sign-in is required to connect to the server or list tools. However, individual tools may still need a vendor account, credentials, or permissions. You must check the documented prerequisites for each specific task.
Can I use this server to estimate construction materials?
Yes. The server includes the estimate_materials tool, which can calculate quantities for bricks, blocks, and mortar. This is suitable for agents needing material quantity estimates for UK building projects.
Does the server handle Party Wall Act notices?
Yes. The party_wall_notices tool can calculate notice dates and required notices. This fits tasks involving Party Wall Act compliance for UK builders.
What tasks does the check_building_regs tool support?
The check_building_regs tool determines the Building Regulations route and applicable Parts. It helps agents assess whether a project requires Building Regulations notification.