Plan Comply MCP
An automated regulatory pre-submission audit engine for South African building plans. It allows AI agents to verify architectural drawings against SANS 10400 standards, check municipal bylaws, calculate compliance metrics like fenestration and stair ergonomics, and retrieve submission checklists to flag potential rejection triggers before council lodgement.
Endpoint and access
No sign-in to connect and list tools. Individual tools may still need a vendor account, credentials, or permissions; check the documented prerequisites.
https://api.plancomply.co.za/mcpWhat you can do with it
- Search SANS 10400 clauses by Part or Category
- Retrieve council submission document checklists
- Calculate mandatory glazing and ventilation requirements
- Validate stair riser, going, and headroom compliance
Source and maintenance
Protocol and capabilities
- Server
- Plan Comply SANS 10400 Regulatory Connector 1.0.0
- MCP protocol
- 2025-06-18
- Tools
- 7 advertised
- Resources
- 0 advertised
- Resource templates
- 0 advertised
- Prompts
- 0 advertised
{
"tools": {
"listChanged": false
},
"prompts": {
"listChanged": false
},
"resources": {
"listChanged": false
}
}Tools
7 advertised
get_sans_rules
Search and query South African National Building Regulations (SANS 10400) clauses by Part (A to XA) or category (Dimensions, Glazing, Fire, Ventilation, Drainage, Stairs, Walls, Documentation).
{
"type": "object",
"properties": {
"query": {
"type": "string",
"description": "Optional keyword search term to match within rule titles, descriptions, and guidance notes."
},
"category": {
"type": "string",
"description": "Category filter (e.g. \"Dimensions\", \"Glazing\", \"Stairways\", \"Fire Safety\", \"Drainage\", \"Walls\", \"Energy Efficiency\")."
},
"sans_part": {
"type": "string",
"description": "SANS 10400 Part identifier (e.g. \"Part A\", \"Part C\", \"Part K\", \"Part M\", \"Part N\", \"Part O\", \"Part P\", \"Part S\", \"Part T\", \"Part XA\")."
}
}
}check_municipal_requirements
Retrieve submission document checklists, statutory forms (Form 1/2), geotechnical/dolomite rules, and common rejection delay factors for South African metropolitan municipalities.
{
"type": "object",
"required": [
"municipality"
],
"properties": {
"municipality": {
"type": "string",
"description": "Municipality name or abbreviation (e.g. \"City of Johannesburg\", \"COJ\", \"Tshwane\", \"Pretoria\", \"City of Cape Town\", \"COCT\", \"Ekurhuleni\", \"eThekwini\", \"Durban\")."
}
}
}get_common_rejection_pitfalls
Retrieve top 25 common reasons municipal building control examiners reject building plans in South Africa, accompanied by verified remediation steps.
{
"type": "object",
"properties": {
"category": {
"enum": [
"all",
"documentation",
"zoning",
"glazing",
"lighting_ventilation",
"drainage",
"stairs",
"safety",
"fire",
"parking",
"accessibility",
"energy"
],
"type": "string",
"description": "Optional category filter. Defaults to all."
}
}
}calculate_sans_fenestration
Calculate SANS 10400-O statutory natural lighting (min. 10% floor area) and natural ventilation (min. 5% openable sash area) compliance for habitable rooms.
{
"type": "object",
"required": [
"floor_area_m2"
],
"properties": {
"room_name": {
"type": "string",
"description": "Name or label of the habitable room (e.g. \"Bedroom 1\", \"Living Room\", \"Study\")."
},
"floor_area_m2": {
"type": "number",
"description": "Internal floor area of the habitable room in square metres (m²)."
},
"actual_glazed_area_m2": {
"type": "number",
"description": "Total installed window glazed area in square metres (m²)."
},
"actual_openable_area_m2": {
"type": "number",
"description": "Total installed clear openable window sash ventilation area in square metres (m²)."
}
}
}calculate_stair_compliance
Evaluate stairway geometry and life safety against SANS 10400-M standards (riser max 200 mm, going min 250 mm, 2R + G formula 570-650 mm, headroom min 2,100 mm).
{
"type": "object",
"required": [
"riser_mm",
"going_mm"
],
"properties": {
"going_mm": {
"type": "number",
"description": "Stair tread horizontal going in millimetres excluding nosing (must not be less than 250 mm)."
},
"riser_mm": {
"type": "number",
"description": "Stair riser vertical height in millimetres (must not exceed 200 mm)."
},
"headroom_mm": {
"type": "number",
"description": "Vertical headroom clearance in millimetres measured vertically from the nosing pitch line (must be min. 2,100 mm)."
},
"baluster_gap_mm": {
"type": "number",
"description": "Maximum clear gap between vertical balusters in millimetres (must not exceed 100 mm)."
},
"balustrade_height_mm": {
"type": "number",
"description": "Height of balustrade in millimetres (min. 1,000 mm on landings, 850 mm on flights)."
}
}
}get_credit_pricing
Retrieve official Plan Comply pre-submission plan audit credit packages, volume discounts, and checkout details.
{
"type": "object",
"properties": {}
}pre_check_building_plan
Run an automated multi-point regulatory validation on building plan specifications and return a compliance readiness score, defect warnings, and submission checklist.
{
"type": "object",
"required": [
"municipality"
],
"properties": {
"municipality": {
"type": "string",
"description": "Target South African municipality for plan submission (e.g. \"City of Johannesburg\", \"Tshwane\", \"City of Cape Town\", \"Ekurhuleni\", \"eThekwini\")."
},
"project_name": {
"type": "string",
"description": "Name of the building or architectural project."
},
"building_class": {
"type": "string",
"description": "Occupancy classification (e.g. \"H4 Single Dwelling House\", \"H3 Multi-Dwelling\", \"G1 Offices\", \"F1 Retail\"). Default is \"H4 Single Dwelling House\"."
},
"has_sans_forms": {
"type": "boolean",
"description": "Whether SANS 10400 Form 1 and Form 2 (if structural work included) are prepared."
},
"has_sacap_declaration": {
"type": "boolean",
"description": "Whether the drawing title block contains the registered architectural professional full name, registration number, category, and signature."
},
"habitable_room_height_mm": {
"type": "number",
"description": "Specified clear finished floor-to-ceiling height in habitable rooms in millimetres (min. 2,400 mm)."
},
"has_rodding_eyes_at_bends": {
"type": "boolean",
"description": "Whether rodding eyes or inspection chambers are provided at drainage bends > 45° and junctions."
},
"external_wall_thickness_mm": {
"type": "number",
"description": "External wall thickness in millimetres (standard cavity wall is min. 270 mm)."
},
"has_renewable_water_heating": {
"type": "boolean",
"description": "Whether min. 50% solar water heating or heat pump is specified as required by SANS 10400-XA."
},
"gully_height_above_ground_mm": {
"type": "number",
"description": "Height of sewer gully head coping above finished ground level in millimetres (min. 150 mm)."
},
"has_safety_glass_below_800mm": {
"type": "boolean",
"description": "Whether safety glass (SANS 1263-1) is specified for all glazing with sill < 800 mm from FFL."
}
}
}Prompts
0 advertised
Resources
0 advertised
30-day availability
Aggregated from read-only remote checks; this is not a tool-execution or security guarantee.
- Successful checks
- 1 of 1 (100%)
- Average latency
- 372 ms
- 95th percentile latency
- 372 ms
Maintenance history
Public check and source-refresh events. Editorial and ownership records remain private.
- · probe · passed · 372 ms · metadata changed · 7 tool(s), 0 resource(s), 0 resource template(s), 0 prompt(s)
Connect from your client
Each snippet registers the same endpoint; pick the client you use.
Claude Code
claude mcp add --transport http plan-comply-mcp https://api.plancomply.co.za/mcpCodex
codex mcp add plan-comply-mcp --url https://api.plancomply.co.za/mcpCursor
{
"mcpServers": {
"plan-comply-mcp": {
"url": "https://api.plancomply.co.za/mcp"
}
}
}Cline
{
"mcpServers": {
"plan-comply-mcp": {
"type": "streamableHttp",
"url": "https://api.plancomply.co.za/mcp",
"disabled": false
}
}
}VS Code
{
"servers": {
"plan-comply-mcp": {
"type": "http",
"url": "https://api.plancomply.co.za/mcp"
}
}
}Gemini CLI
gemini mcp add --transport http plan-comply-mcp https://api.plancomply.co.za/mcpClaude Desktop
{
"mcpServers": {
"plan-comply-mcp": {
"url": "https://api.plancomply.co.za/mcp"
}
}
}Windsurf
{
"mcpServers": {
"plan-comply-mcp": {
"serverUrl": "https://api.plancomply.co.za/mcp"
}
}
}Let your agent find its tools
Find servers like Plan Comply MCP from your agent. Add Koskamo once to search the index for endpoints, access requirements, and client setup. Public discovery needs no key.
Other productivity and knowledge servers
Do you run Plan Comply MCP?
Prove ownership with a DNS record, a well-known file, or your Official MCP Registry entry, and your edits publish immediately. Proofs are re-checked weekly; admins can still hide or remove a listing.