Future Micro Mold Lab MCP
An official MCP server providing access to scientific molding calculators including viscosity curve, cavity balance, pressure drop, cosmetic window, gate seal, cooling time, gage R&R, and Cpk. It allows agents to run these studies and retrieve results with links to pre-loaded data.
Endpoint and access
No sign-in to connect and list tools. Individual tools may still need a vendor account, credentials, or permissions; check the documented prerequisites.
https://www.futuremicromoldllc.com/api/mcpWhat its tools do
11 tools, grouped by the hints the server advertises. Hints are self-declared, not verified behavior.
Checks and signals
Each line is separate evidence, not a trust score.
- Passed Endpoint answered the live check ·
- Passed Official MCP Registry namespace is tied to futuremicromoldllc.com ·
- Passed Endpoint is on the registry namespace domain ·
- Uptime 100% over 90 days
- Availability 2 of 2 checks passed in 30 days
What you can do with it
- Calculate optimal injection velocity via viscosity curve study
- Quantify cavity-to-cavity fill imbalance from short-shot weights
- Find hold time at which the gate freezes and part weight stops rising
- Judge process capability (Cp, Cpk) for dimensional tolerance
Source and maintenance
Protocol and capabilities
- Server
- future-micro-mold-lab 1.0.0
- MCP protocol negotiated in check
- 2025-11-25
- Tools
- 11 advertised
- Resources
- 1 advertised
- Resource templates
- 0 advertised
- Prompts
- Not advertised
{
"tools": {
"listChanged": true
},
"resources": {
"listChanged": true
}
}Server-provided instructions
Untrusted server output shown for inspection. It is not Koskamo guidance and is excluded from knowledge search.
Tools
11 advertised
viscosity_curve — Viscosity curve study
Find the optimal injection velocity from a velocity / peak-pressure sweep. Computes relative viscosity (plastic pressure times fill time) against relative shear rate, locates the shear-thinning plateau, and picks a velocity from the middle of it. Record a fill time on every point for a result that transfers between machines. This is the first study in the sequence; every later study holds its velocity constant.
{
"type": "object",
"$schema": "https://json-schema.org/draft/2020-12/schema",
"properties": {
"points": {
"type": "array",
"items": {
"type": "object",
"required": [
"velocity",
"pressure"
],
"properties": {
"fillTime": {
"type": "number",
"description": "Seconds to fill, first stage only"
},
"pressure": {
"type": "number",
"description": "Peak injection pressure as read on the machine, psi"
},
"velocity": {
"type": "number",
"description": "Injection velocity, in/s"
}
}
},
"maxItems": 100,
"minItems": 2
},
"context": {
"type": "object",
"properties": {
"material": {
"type": "string",
"maxLength": 64
},
"meltTempC": {
"type": "number"
},
"moldTempC": {
"type": "number"
}
}
},
"study_code": {
"type": "string",
"maxLength": 8000,
"minLength": 1,
"description": "A study as the Lab card encodes it; use instead of the measurements (points, intensificationRatio, machineMaxPressure)"
},
"machineMaxPressure": {
"type": "number",
"description": "Machine maximum injection pressure, same units as pressure"
},
"intensificationRatio": {
"type": "number",
"description": "Hydraulic-to-plastic multiplier; omit if pressure is already plastic"
}
}
}{
"title": "Viscosity curve study",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}cavity_balance — Cavity balance study
Quantify cavity-to-cavity fill imbalance from short-shot weights. Give two or more replicate shots at a fill level and the result also says whether the variation comes from the cavities (runner and gate geometry) or from shot-to-shot process drift — the two have opposite fixes. Judge balance on a short shot at 90% fill or above.
{
"type": "object",
"$schema": "https://json-schema.org/draft/2020-12/schema",
"properties": {
"levels": {
"type": "array",
"items": {
"type": "object",
"required": [
"fillPct",
"shots"
],
"properties": {
"shots": {
"type": "array",
"items": {
"type": "object",
"propertyNames": {
"type": "string",
"maxLength": 8,
"minLength": 1
},
"additionalProperties": {
"type": "number"
}
},
"maxItems": 100,
"minItems": 1,
"description": "One entry per shot, mapping cavity name to part weight in grams"
},
"fillPct": {
"type": "number",
"description": "Short-shot fill percentage, e.g. 95"
}
}
},
"maxItems": 100,
"minItems": 1,
"description": "One entry per fill percentage tested — e.g. a 50%, then a 95%, short shot."
},
"context": {
"type": "object",
"properties": {
"material": {
"type": "string",
"maxLength": 64
},
"meltTempC": {
"type": "number"
},
"moldTempC": {
"type": "number"
}
}
},
"study_code": {
"type": "string",
"maxLength": 8000,
"minLength": 1,
"description": "A study as the Lab card encodes it; use instead of the measurements (levels)"
}
}
}{
"title": "Cavity balance study",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}pressure_drop — Pressure-drop study
Find where injection pressure is consumed along the flow path. Each reading is the CUMULATIVE peak pressure needed to fill through that section — an air shot gives the nozzle figure, then sprue, runner, gate and the full part — so the values ascend. Known sections: Nozzle, Sprue, Runner, Gate, Part. Run every reading at the velocity the viscosity curve selected.
{
"type": "object",
"$schema": "https://json-schema.org/draft/2020-12/schema",
"properties": {
"stages": {
"type": "array",
"items": {
"type": "object",
"required": [
"stage",
"pressure"
],
"properties": {
"stage": {
"type": "string",
"maxLength": 24,
"description": "Section name, e.g. one of: Nozzle, Sprue, Runner, Gate, Part"
},
"pressure": {
"type": "number",
"description": "Cumulative peak pressure to fill through this section, psi"
}
}
},
"maxItems": 100,
"minItems": 2
},
"context": {
"type": "object",
"properties": {
"material": {
"type": "string",
"maxLength": 64
},
"meltTempC": {
"type": "number"
},
"moldTempC": {
"type": "number"
}
}
},
"study_code": {
"type": "string",
"maxLength": 8000,
"minLength": 1,
"description": "A study as the Lab card encodes it; use instead of the measurements (stages, machineMaxPressure, intensificationRatio)"
},
"machineMaxPressure": {
"type": "number",
"description": "Machine maximum injection pressure, same units as pressure"
},
"intensificationRatio": {
"type": "number",
"description": "Hydraulic-to-plastic multiplier; omit if pressure is already plastic"
}
}
}{
"title": "Pressure-drop study",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}cosmetic_window — Cosmetic process-window study
Map which combinations of two process parameters produce a cosmetically acceptable part, and how much room surrounds the center. Sweep wider than you expect the window to be: a passing point on the edge of the range tested means the window was never closed on that side. Axes and their units: hold_pressure (psi), melt_temp (°C), mold_temp (°C), injection_velocity (in/s), hold_time (s), cooling_time (s). Defects: short, flash, sink, burn, splay, weld-line, drag, warp.
{
"type": "object",
"$schema": "https://json-schema.org/draft/2020-12/schema",
"properties": {
"xAxis": {
"enum": [
"hold_pressure",
"melt_temp",
"mold_temp",
"injection_velocity",
"hold_time",
"cooling_time"
],
"type": "string",
"description": "Horizontal parameter. Units by axis: hold_pressure (psi), melt_temp (°C), mold_temp (°C), injection_velocity (in/s), hold_time (s), cooling_time (s)."
},
"yAxis": {
"enum": [
"hold_pressure",
"melt_temp",
"mold_temp",
"injection_velocity",
"hold_time",
"cooling_time"
],
"type": "string",
"description": "Vertical parameter. Units by axis: hold_pressure (psi), melt_temp (°C), mold_temp (°C), injection_velocity (in/s), hold_time (s), cooling_time (s)."
},
"points": {
"type": "array",
"items": {
"type": "object",
"required": [
"x",
"y",
"pass"
],
"properties": {
"x": {
"type": "number",
"description": "Value on the x axis, in the unit of whichever axis xAxis selects"
},
"y": {
"type": "number",
"description": "Value on the y axis, in the unit of whichever axis yAxis selects"
},
"pass": {
"type": "boolean",
"description": "Did the part meet the cosmetic criteria?"
},
"defect": {
"enum": [
"short",
"flash",
"sink",
"burn",
"splay",
"weld-line",
"drag",
"warp"
],
"type": "string"
}
}
},
"maxItems": 100,
"minItems": 2
},
"context": {
"type": "object",
"properties": {
"material": {
"type": "string",
"maxLength": 64
},
"meltTempC": {
"type": "number"
},
"moldTempC": {
"type": "number"
}
}
},
"study_code": {
"type": "string",
"maxLength": 8000,
"minLength": 1,
"description": "A study as the Lab card encodes it; use instead of the measurements (xAxis, yAxis, points)"
}
}
}{
"title": "Cosmetic process-window study",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}gate_seal — Gate-seal study
Find the hold time at which the gate freezes and part weight stops rising. Seal is the first of three consecutive weights within 0.1% of each other that weight does not climb above afterwards; the recommended production hold time adds a margin of one increment (0.5–1.0 s). Weigh to 0.1% of part weight or better. A weight that falls back after seal means the gate did not stay frozen. Run at the velocity the viscosity curve selected.
{
"type": "object",
"$schema": "https://json-schema.org/draft/2020-12/schema",
"properties": {
"points": {
"type": "array",
"items": {
"type": "object",
"required": [
"holdTime",
"partWeight"
],
"properties": {
"holdTime": {
"type": "number",
"description": "Hold time, seconds"
},
"partWeight": {
"type": "number",
"description": "Average part weight, grams"
},
"keyDimension": {
"type": "number",
"description": "A key dimension measured on the same parts, mm or inches — use whichever the drawing calls out, consistently across all points"
},
"cushionPosition": {
"type": "number",
"description": "Cushion, mm"
}
}
},
"maxItems": 100,
"minItems": 2
},
"context": {
"type": "object",
"properties": {
"material": {
"type": "string",
"maxLength": 64
},
"meltTempC": {
"type": "number"
},
"moldTempC": {
"type": "number"
}
}
},
"study_code": {
"type": "string",
"maxLength": 8000,
"minLength": 1,
"description": "A study as the Lab card encodes it; use instead of the measurements (points)"
}
}
}{
"title": "Gate-seal study",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}cooling_time — Cooling-time study
Find the shortest cooling time at which a dimension has stopped changing, and the cycle seconds that come off. Supply the drawing tolerance and the rule tightens to a tenth of it. Measure each part at a consistent interval after ejection — the part keeps moving.
{
"type": "object",
"$schema": "https://json-schema.org/draft/2020-12/schema",
"properties": {
"points": {
"type": "array",
"items": {
"type": "object",
"required": [
"coolingTime",
"dimension"
],
"properties": {
"dimension": {
"type": "number",
"description": "Measured dimension, consistent units"
},
"coolingTime": {
"type": "number",
"description": "Cooling time, seconds"
}
}
},
"maxItems": 100,
"minItems": 2
},
"context": {
"type": "object",
"properties": {
"material": {
"type": "string",
"maxLength": 64
},
"meltTempC": {
"type": "number"
},
"moldTempC": {
"type": "number"
}
}
},
"study_code": {
"type": "string",
"maxLength": 8000,
"minLength": 1,
"description": "A study as the Lab card encodes it; use instead of the measurements (points, dimensionName, dimensionTolerance)"
},
"dimensionName": {
"type": "string",
"maxLength": 48
},
"dimensionTolerance": {
"type": "number",
"description": "Total drawing tolerance, same units as dimension"
}
}
}{
"title": "Cooling-time study",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}process_capability — Process capability (Cp, Cpk, Pp, Ppk)
Judge whether a running process can hold a dimension inside its tolerance. Reports Cp and Cpk from within-subgroup sigma and Pp and Ppk from overall sigma — the second pair is the overall figure many customer reports quote — each with a 95% confidence interval, an upper bound on parts per million out of spec, and an Anderson–Darling normality check. Estimators follow Minitab's defaults. The verdict takes the lower of Cpk and Ppk, so a mean that drifted during the run is not called capable. No verdict is given when the data cannot support one (no limit, zero spread, badly non-normal data). One specification limit is enough. Sample at least 25 consecutive parts without adjusting the process.
{
"type": "object",
"$schema": "https://json-schema.org/draft/2020-12/schema",
"properties": {
"lsl": {
"type": "number",
"description": "Lower specification limit"
},
"usl": {
"type": "number",
"description": "Upper specification limit"
},
"target": {
"type": "number",
"description": "Nominal from the drawing. Used only to sanity-check it against usl/lsl (a warning when it falls outside them) — not carried into the share link, since the snapshot has no field for it."
},
"samples": {
"type": "array",
"items": {
"type": "number"
},
"maxItems": 100,
"minItems": 2,
"description": "Measurements in production order"
},
"study_code": {
"type": "string",
"maxLength": 8000,
"minLength": 1,
"description": "A study as the Lab card encodes it; use instead of the measurements (samples, usl, lsl, target, subgroupSize, withinMethod)"
},
"subgroupSize": {
"type": "integer",
"maximum": 100,
"minimum": 1,
"description": "Consecutive measurements per rational subgroup. Omit or 1 for individuals (within sigma from the moving range)."
},
"withinMethod": {
"enum": [
"pooled",
"rbar"
],
"type": "string",
"description": "Within-sigma estimator when subgroupSize > 1: pooled standard deviation (default, as Minitab) or R-bar/d2."
}
}
}{
"title": "Process capability (Cp, Cpk, Pp, Ppk)",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}gage_rr — Gage R&R (crossed, ANOVA method)
Rate a measurement system from a crossed study: every operator measures every part, the same number of times. Two-way ANOVA per the AIAG Measurement Systems Analysis manual (4th ed.), matching Minitab's crossed gage R&R defaults: the operator × part interaction is pooled into repeatability when not significant (α = 0.05). Reports %GRR of study variation and, when a tolerance is given, of the tolerance, the repeatability / reproducibility split, the number of distinct categories, and the AIAG band (under 10% acceptable, 10–30% conditional, over 30% unacceptable). The standard study is 10 parts, 3 operators, 2–3 trials. Run it before trusting a Cpk.
{
"type": "object",
"$schema": "https://json-schema.org/draft/2020-12/schema",
"properties": {
"context": {
"type": "object",
"properties": {
"material": {
"type": "string",
"maxLength": 64
},
"meltTempC": {
"type": "number"
},
"moldTempC": {
"type": "number"
}
}
},
"operators": {
"type": "array",
"items": {
"type": "object",
"required": [
"trials"
],
"properties": {
"name": {
"type": "string",
"maxLength": 16,
"description": "Operator label, e.g. \"A\". For your own bookkeeping; the calculation and the readout identify operators by position."
},
"trials": {
"type": "array",
"items": {
"type": "array",
"items": {
"type": "number"
},
"maxItems": 30,
"minItems": 2
},
"maxItems": 6,
"minItems": 2,
"description": "One array per trial, each listing this operator's readings for parts 1…N in the same part order, in the dimension's own units"
}
}
},
"maxItems": 6,
"minItems": 2
},
"tolerance": {
"type": "number",
"description": "Tolerance width (upper limit minus lower limit), same units as the readings. Enables %GRR of tolerance, which is what a Cpk study needs.",
"exclusiveMinimum": 0
},
"study_code": {
"type": "string",
"maxLength": 8000,
"minLength": 1,
"description": "A study as the Lab card encodes it; use instead of the measurements (operators, tolerance)"
}
}
}{
"title": "Gage R&R (crossed, ANOVA method)",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}get_study_protocol — How to run a study
Return the full procedure for one study: what it is for, the equipment needed, the step-by-step method at the press, and what a good result looks like, so the numbers collected at the press are the ones the calculation needs.
{
"type": "object",
"$schema": "https://json-schema.org/draft/2020-12/schema",
"required": [
"study"
],
"properties": {
"study": {
"enum": [
"viscosity_curve",
"cavity_balance",
"pressure_drop",
"cosmetic_window",
"gate_seal",
"cooling_time",
"gage_rr",
"process_capability"
],
"type": "string",
"description": "Which study to explain"
}
}
}{
"title": "How to run a study",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}plan_process_development — Plan the study sequence
Given the studies already run, return the full development sequence with each one marked done or outstanding, what each fixes, what it depends on, and which study to run next. The order matters: each study fixes a setpoint the next one holds constant, so running them out of order produces numbers that do not transfer.
{
"type": "object",
"$schema": "https://json-schema.org/draft/2020-12/schema",
"properties": {
"completed": {
"type": "array",
"items": {
"enum": [
"viscosity_curve",
"cavity_balance",
"pressure_drop",
"cosmetic_window",
"gate_seal",
"cooling_time",
"gage_rr",
"process_capability"
],
"type": "string"
},
"default": [],
"maxItems": 8,
"description": "Studies already run"
},
"setpoints": {
"type": "object",
"properties": {
"holdTime": {
"type": "number"
},
"meltTemp": {
"type": "number"
},
"coolingTime": {
"type": "number"
},
"packPressure": {
"type": "number"
},
"injectionVelocity": {
"type": "number"
}
},
"description": "Setpoints fixed so far, from each study result",
"additionalProperties": false
}
}
}{
"title": "Plan the study sequence",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}open_study_sheet — Open a study data sheet
Open an empty data sheet for one study in an interactive card: the procedure beside a table the person fills in or pastes into, with the result computed as they type. Also returns the procedure as text and a link to the same calculator on the Lab website.
{
"type": "object",
"$schema": "https://json-schema.org/draft/2020-12/schema",
"required": [
"study"
],
"properties": {
"study": {
"enum": [
"viscosity_curve",
"cavity_balance",
"pressure_drop",
"cosmetic_window",
"gate_seal",
"cooling_time",
"gage_rr",
"process_capability"
],
"type": "string",
"description": "Which study"
},
"setpoints": {
"type": "object",
"properties": {
"holdTime": {
"type": "number"
},
"meltTemp": {
"type": "number"
},
"coolingTime": {
"type": "number"
},
"packPressure": {
"type": "number"
},
"injectionVelocity": {
"type": "number"
}
},
"description": "Setpoints fixed so far, shown above the sheet",
"additionalProperties": false
}
}
}{
"title": "Open a study data sheet",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}Prompts
Not advertised
Resources
1 advertised
Lab study card
A scientific-molding study as an interactive card: data sheet, chart and result, or the setup sequence.
ui://future-micro-mold/lab-card.html90-day uptime
A lightweight connection check about every six hours, sampled on hosts with many listings. It shows the server answered, not that its tools work.
- 2026-11-17: 2 of 2 checks answered
- 2026-11-18: 5 of 5 checks answered
- 2026-11-19: 4 of 4 checks answered
- 2026-11-20: 3 of 3 checks answered
- 2026-11-21: 4 of 4 checks answered
- 2026-11-22: 4 of 4 checks answered
- 2026-11-23: 3 of 3 checks answered
- 2026-11-24: 2 of 2 checks answered
30-day availability
Aggregated from read-only remote checks; this is not a tool-execution or security guarantee.
- Successful checks
- 2 of 2 (100%)
- Average latency
- 3736 ms
- 95th percentile latency
- 6135 ms
Maintenance history
Public check and source-refresh events. Editorial and ownership records remain private.
- · probe · passed · 6402 ms · metadata changed · 11 tool(s), 1 resource(s), 0 resource template(s)
- · probe · passed · 1069 ms · metadata changed · 11 tool(s), 1 resource(s), 0 resource template(s)
Connect from your client
Each snippet registers the same endpoint; pick the client you use.
Claude Code
claude mcp add --transport http future-micro-mold-lab-mcp https://www.futuremicromoldllc.com/api/mcpCodex
codex mcp add future-micro-mold-lab-mcp --url https://www.futuremicromoldllc.com/api/mcpCursor
{
"mcpServers": {
"future-micro-mold-lab-mcp": {
"url": "https://www.futuremicromoldllc.com/api/mcp"
}
}
}Cline
{
"mcpServers": {
"future-micro-mold-lab-mcp": {
"type": "streamableHttp",
"url": "https://www.futuremicromoldllc.com/api/mcp",
"disabled": false
}
}
}VS Code
{
"servers": {
"future-micro-mold-lab-mcp": {
"type": "http",
"url": "https://www.futuremicromoldllc.com/api/mcp"
}
}
}Gemini CLI
gemini mcp add --transport http future-micro-mold-lab-mcp https://www.futuremicromoldllc.com/api/mcpClaude Desktop
https://www.futuremicromoldllc.com/api/mcpWindsurf
{
"mcpServers": {
"future-micro-mold-lab-mcp": {
"serverUrl": "https://www.futuremicromoldllc.com/api/mcp"
}
}
}Let your agent find its tools
Find servers like Future Micro Mold Lab MCP from your agent. Add Koskamo once to search the index for endpoints, access requirements, and client setup. Public discovery needs no key.
Other developer tools servers
Do you run Future Micro Mold Lab MCP?
Prove ownership with a DNS record, a well-known file, or your Official MCP Registry entry, and your edits publish immediately. Proofs are re-checked weekly; admins can still hide or remove a listing.