Flow Pack MCP
A remote MCP server providing UK plumbing and heating calculations for AI assistants, including pipe sizing, heat loss analysis, radiator sizing, notifiable work checks, gas record validation, and emergency triage guidance.
Endpoint and access
No sign-in to connect and list tools. Individual tools may still need a vendor account, credentials, or permissions; check the documented prerequisites.
https://flow-pack.nerolabs.workers.dev/mcpWhat its tools do
8 tools, grouped by the hints the server advertises. Hints are self-declared, not verified behavior.
Checks and signals
Each line is separate evidence, not a trust score.
- Passed Endpoint answered the live check ·
- Uptime 100% over 90 days
- Availability 3 of 3 checks passed in 30 days
About Flow Pack MCP
Flow Pack MCP is a developer tool server operated by Nero Labs that delivers UK plumbing and heating calculations for AI assistants. It supports tasks such as calculating water or gas pipe size, velocity, and pressure loss, as well as determining room-by-room heat loss to size boilers or heat pumps.
The server also assists with compliance and safety checks. Agents can use it to verify if a plumbing job requires Gas Safe or building control notification, validate landlord gas safety records for missing fields, and access emergency triage guidance. The available tools include check_gas_record, check_notifiable_work, emergency_triage, list_capabilities, size_heat_source, size_pipe, size_radiators, and trade_profile.
Connection to the server requires no sign-in. However, individual tools may still need a vendor account, credentials, or permissions. Users must check the documented prerequisites for specific tasks before execution.
What you can do with it
- Calculate water or gas pipe size, velocity, and pressure loss
- Determine room-by-room heat loss and boiler or heat pump size
- Check if a plumbing job requires Gas Safe or building control notification
- Validate landlord gas safety records for missing fields or errors
Source and maintenance
- Maintenance checked
Protocol and capabilities
- Server
- nerolabs-flow-pack 1.1.0
- MCP protocol negotiated in check
- 2025-06-18
- Tools
- 8 advertised
- Resources
- Not advertised
- Resource templates
- Not advertised
- Prompts
- Not advertised
{
"tools": {
"listChanged": false
}
}Server-provided instructions
Untrusted server output shown for inspection. It is not Koskamo guidance and is excluded from knowledge search.
Tools
8 advertised
list_capabilities — What Flow Pack can do
Lists Flow Pack's tools, what it covers (nations, pipe materials, gases, record types, emergency situations) and what it deliberately does not do. Free, needs no input.
{
"type": "object",
"properties": {},
"additionalProperties": false
}{
"title": "What Flow Pack can do",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}size_pipe — Water or gas pipe size, velocity and pressure loss
Sizes a hot or cold water pipe, or a low-pressure gas pipe, and shows the working. Water: design flow (from outlets, with a simple in-use-at-once rule, or a flow you give), velocity against a limit (1.5 m/s default), pressure loss per metre and in total, and the pressure left at the outlet if you give the supply pressure. Gas: flow from the gross heat input of the appliances fed, pressure drop against the 1 mbar natural gas (2.5 mbar LPG) allowance, with a meter capacity warning. Returns `recommended` (smallest size that passes), `sizes_considered`, `must_check` (points the engineer confirms) and sources. Calculated from fluid physics (Darcy-Weisbach); no BS EN 806 or BS 6891 tables are reproduced. Typical calls: {"medium":"gas","heat_input_kw_gross":30,"run_length_m":12,"fittings":{"elbows":5}} or {"medium":"water","service":"cold","outlets":[{"type":"bath"},{"type":"kitchen_sink"},{"type":"basin"},{"type":"wc"},{"type":"shower_mixer"}],"run_length_m":15,"supply_pressure_bar":2.5,"height_rise_m":3}.
{
"type": "object",
"required": [
"medium",
"run_length_m"
],
"properties": {
"gas": {
"enum": [
"natural_gas",
"lpg_propane"
],
"type": "string",
"description": "Gas only. Default natural_gas."
},
"trade": {
"type": "object",
"properties": {
"town": {
"type": "string"
},
"email": {
"type": "string"
},
"phone": {
"type": "string"
},
"address": {
"type": "string",
"description": "Business address for record headers."
},
"postcode": {
"type": "string"
},
"categories": {
"type": "array",
"items": {
"type": "string"
},
"description": "Trades offered, using Nero Work trade names. Defaults to [\"plumber\", \"heating\"]."
},
"company_name": {
"type": "string",
"description": "Registered company name, if a limited company."
},
"display_name": {
"type": "string",
"description": "Trading name shown to customers, for example \"Northside Plumbing & Heating\"."
},
"licence_body": {
"enum": [
"gas_safe",
"oftec",
"hetas",
"aphc",
"ciphe",
"watersafe",
"mcs",
"niceic",
"napit",
"stroma",
"certsure",
"benchmark",
"other",
"none"
],
"type": "string",
"description": "Registration scheme. For gas work use gas_safe with the business's Gas Safe registration number."
},
"company_number": {
"type": "string",
"description": "Companies House number, for example 12345678 or SC123456."
},
"licence_number": {
"type": "string",
"description": "Scheme registration number (Gas Safe registration numbers are usually 6 or 7 digits)."
}
},
"description": "Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack.",
"additionalProperties": false
},
"medium": {
"enum": [
"water",
"gas"
],
"type": "string"
},
"outlets": {
"type": "array",
"items": {
"type": "object",
"required": [
"type"
],
"properties": {
"type": {
"enum": [
"basin",
"kitchen_sink",
"bath",
"shower_mixer",
"shower_power",
"wc",
"washing_machine",
"dishwasher",
"outside_tap",
"utility_sink"
],
"type": "string"
},
"count": {
"type": "number"
},
"flow_l_s": {
"type": "number",
"description": "Override the typical flow."
}
},
"additionalProperties": false
},
"description": "Water only: outlets this pipe feeds."
},
"service": {
"enum": [
"cold",
"hot"
],
"type": "string",
"description": "Water only. Default cold."
},
"fittings": {
"type": "object",
"properties": {
"bends": {
"type": "number",
"description": "Swept or pulled bend, loss coefficient K 0.4."
},
"elbows": {
"type": "number",
"description": "90 degree elbow (tight), loss coefficient K 0.9."
},
"valves": {
"type": "number",
"description": "Full-bore valve, open, loss coefficient K 0.3."
},
"tees_branch": {
"type": "number",
"description": "Tee, flow into or out of the branch, loss coefficient K 1.5."
},
"tees_through": {
"type": "number",
"description": "Tee, flow straight through, loss coefficient K 0.4."
}
},
"description": "Count of fittings on the run. If left out, 30% is added to the length instead (or fittings_allowance_percent).",
"additionalProperties": false
},
"material": {
"enum": [
"copper",
"plastic",
"mdpe",
"steel",
"csst"
],
"type": "string",
"description": "Water: copper (default), plastic, mdpe. Gas: copper (default), steel, csst."
},
"pipe_size_mm": {
"type": "number",
"description": "Check only this nominal size."
},
"run_length_m": {
"type": "number",
"description": "Measured pipe length, metres (from the meter for gas, from the stop tap or cylinder for water)."
},
"water_temp_c": {
"type": "number",
"description": "Water only. Default 10 cold, 60 hot."
},
"gas_flow_m3_h": {
"type": "number",
"description": "Gas only: gas flow, if already known."
},
"height_rise_m": {
"type": "number",
"description": "Water only: height gained from start to outlet (negative if it falls)."
},
"design_flow_l_s": {
"type": "number",
"description": "Water only: design flow in litres a second, if known (overrides outlets)."
},
"max_velocity_m_s": {
"type": "number",
"description": "Water only. Default 1.5."
},
"allowed_drop_mbar": {
"type": "number",
"description": "Gas only. Default 1 natural gas, 2.5 LPG."
},
"heat_input_kw_net": {
"type": "number",
"description": "Gas only: if only the net figure is known."
},
"heat_input_kw_gross": {
"type": "number",
"description": "Gas only: total gross heat input of every appliance this pipe feeds (data plate)."
},
"supply_pressure_bar": {
"type": "number",
"description": "Water only: working pressure at the start of the run (measured with water flowing)."
},
"simultaneous_outlets": {
"type": "number",
"description": "Water only: how many outlets run at once. Default: square root of the number of outlets, rounded."
},
"fittings_allowance_percent": {
"type": "number",
"description": "Length added for fittings when they are not counted. Default 30."
},
"min_pressure_at_outlet_bar": {
"type": "number",
"description": "Water only: pressure needed at the end. Default 1.0 bar."
}
},
"additionalProperties": false
}{
"title": "Water or gas pipe size",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}size_heat_source — Room by room heat loss, boiler and heat pump size
Works out the heat loss of each room (fabric U x A x delta T plus ventilation 0.33 x air changes x volume x delta T) and the total, then sizes a combi, system or regular boiler, or a heat pump, to the nearest common size. Combi sizing also checks the hot water load (flow x temperature rise). Give each room's type, size and its walls, windows, roof and floor with U values, or construction presets for indicative values. Returns per-room losses with every element's working, the total, the size, `status` (indicative when presets were used), `must_check` and sources. Typical call: {"heat_source":"heat_pump","outside_design_temp_c":-3,"rooms":[{"name":"Lounge","type":"living","floor_area_m2":20,"elements":[{"type":"wall","area_m2":7.8,"construction":"cavity_wall_unfilled"},{"type":"window","area_m2":1.8,"construction":"double_glazed_old"}]}]}.
{
"type": "object",
"required": [
"rooms"
],
"properties": {
"rooms": {
"type": "array",
"items": {
"type": "object",
"properties": {
"name": {
"type": "string"
},
"type": {
"enum": [
"living",
"dining",
"kitchen",
"bedroom",
"bathroom",
"shower_room",
"wc",
"hall",
"landing",
"study",
"utility",
"conservatory",
"other"
],
"type": "string",
"description": "Sets the default temperature and air changes."
},
"elements": {
"type": "array",
"items": {
"type": "object",
"required": [
"area_m2"
],
"properties": {
"type": {
"type": "string",
"description": "Label, for example \"external wall\", \"window\", \"floor\"."
},
"area_m2": {
"type": "number"
},
"u_value": {
"type": "number",
"description": "U value in W/m2K if known. Otherwise give construction."
},
"adjacent": {
"enum": [
"outside",
"ground",
"unheated",
"neighbour",
"heated"
],
"type": "string",
"description": "What is on the other side. Defaults to outside. neighbour = attached home (10 C); unheated = garage or loft space (halfway temperature); heated = another room (give adjacent_temp_c)."
},
"construction": {
"enum": [
"solid_brick_wall",
"cavity_wall_unfilled",
"cavity_wall_filled",
"stone_wall",
"timber_frame_wall",
"new_build_wall",
"internal_wall",
"single_glazed",
"double_glazed_old",
"double_glazed_modern",
"triple_glazed",
"roof_uninsulated",
"roof_100mm",
"roof_270mm",
"floor_suspended_uninsulated",
"floor_solid_uninsulated",
"floor_insulated",
"door_solid_timber",
"door_modern"
],
"type": "string",
"description": "Indicative U value preset when the real one is not known."
},
"adjacent_temp_c": {
"type": "number"
}
},
"additionalProperties": false
}
},
"volume_m3": {
"type": "number"
},
"design_temp_c": {
"type": "number"
},
"floor_area_m2": {
"type": "number"
},
"ceiling_height_m": {
"type": "number",
"description": "Default 2.4."
},
"air_changes_per_hour": {
"type": "number"
}
},
"additionalProperties": false
},
"description": "Up to 40 rooms."
},
"trade": {
"type": "object",
"properties": {
"town": {
"type": "string"
},
"email": {
"type": "string"
},
"phone": {
"type": "string"
},
"address": {
"type": "string",
"description": "Business address for record headers."
},
"postcode": {
"type": "string"
},
"categories": {
"type": "array",
"items": {
"type": "string"
},
"description": "Trades offered, using Nero Work trade names. Defaults to [\"plumber\", \"heating\"]."
},
"company_name": {
"type": "string",
"description": "Registered company name, if a limited company."
},
"display_name": {
"type": "string",
"description": "Trading name shown to customers, for example \"Northside Plumbing & Heating\"."
},
"licence_body": {
"enum": [
"gas_safe",
"oftec",
"hetas",
"aphc",
"ciphe",
"watersafe",
"mcs",
"niceic",
"napit",
"stroma",
"certsure",
"benchmark",
"other",
"none"
],
"type": "string",
"description": "Registration scheme. For gas work use gas_safe with the business's Gas Safe registration number."
},
"company_number": {
"type": "string",
"description": "Companies House number, for example 12345678 or SC123456."
},
"licence_number": {
"type": "string",
"description": "Scheme registration number (Gas Safe registration numbers are usually 6 or 7 digits)."
}
},
"description": "Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack.",
"additionalProperties": false
},
"heat_source": {
"enum": [
"combi_boiler",
"system_boiler",
"regular_boiler",
"heat_pump"
],
"type": "string",
"description": "Default combi_boiler."
},
"reheat_hours": {
"type": "number",
"description": "Wanted reheat time. Default 1."
},
"margin_percent": {
"type": "number",
"description": "Added to the heating load. Default 10 for boilers, 0 for heat pumps."
},
"cylinder_litres": {
"type": "number",
"description": "System or regular boiler: cylinder size. Default 150."
},
"hot_water_priority": {
"type": "boolean",
"description": "Default true (reheat load not added)."
},
"hot_water_flow_l_min": {
"type": "number",
"description": "Combi: wanted hot water flow. Default 12."
},
"hot_water_temp_rise_c": {
"type": "number",
"description": "Combi: temperature rise. Default 35."
},
"outside_design_temp_c": {
"type": "number",
"description": "Local outside design temperature. Default -3."
}
},
"additionalProperties": false
}{
"title": "Heat loss and heat source size",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}size_radiators — Radiator size per room, including at heat pump temperatures
For each room's heat loss, works out the rated (delta T 50) radiator output needed at the system's flow and return temperatures, using output = rated x (mean water to air difference / 50) ^ 1.3. Shows how far an existing radiator falls short, the water flow per radiator, indicative lengths by panel type, and with compare_flow_temp_c how much bigger radiators must be at a lower flow temperature (for example 70 C boiler to 45 C heat pump). Typical call: {"flow_temp_c":45,"rooms":[{"name":"Lounge","heat_loss_w":1500,"existing_rated_output_w":1800}],"compare_flow_temp_c":70}.
{
"type": "object",
"required": [
"rooms"
],
"properties": {
"rooms": {
"type": "array",
"items": {
"type": "object",
"required": [
"heat_loss_w"
],
"properties": {
"name": {
"type": "string"
},
"heat_loss_w": {
"type": "number"
},
"design_temp_c": {
"type": "number",
"description": "Default 21."
},
"existing_rated_output_w": {
"type": "number",
"description": "The radiator's delta T 50 output, if one is fitted."
}
},
"additionalProperties": false
}
},
"trade": {
"type": "object",
"properties": {
"town": {
"type": "string"
},
"email": {
"type": "string"
},
"phone": {
"type": "string"
},
"address": {
"type": "string",
"description": "Business address for record headers."
},
"postcode": {
"type": "string"
},
"categories": {
"type": "array",
"items": {
"type": "string"
},
"description": "Trades offered, using Nero Work trade names. Defaults to [\"plumber\", \"heating\"]."
},
"company_name": {
"type": "string",
"description": "Registered company name, if a limited company."
},
"display_name": {
"type": "string",
"description": "Trading name shown to customers, for example \"Northside Plumbing & Heating\"."
},
"licence_body": {
"enum": [
"gas_safe",
"oftec",
"hetas",
"aphc",
"ciphe",
"watersafe",
"mcs",
"niceic",
"napit",
"stroma",
"certsure",
"benchmark",
"other",
"none"
],
"type": "string",
"description": "Registration scheme. For gas work use gas_safe with the business's Gas Safe registration number."
},
"company_number": {
"type": "string",
"description": "Companies House number, for example 12345678 or SC123456."
},
"licence_number": {
"type": "string",
"description": "Scheme registration number (Gas Safe registration numbers are usually 6 or 7 digits)."
}
},
"description": "Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack.",
"additionalProperties": false
},
"flow_temp_c": {
"type": "number",
"description": "Default 70."
},
"return_temp_c": {
"type": "number",
"description": "Default flow minus 10 (minus 5 at 55 C or lower)."
},
"radiator_exponent": {
"type": "number",
"description": "Default 1.3."
},
"compare_flow_temp_c": {
"type": "number"
},
"compare_return_temp_c": {
"type": "number"
}
},
"additionalProperties": false
}{
"title": "Radiator sizing",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}check_notifiable_work — Is this work notifiable, and who can do it?
For plumbing and heating jobs in England or Wales: does it need a Gas Safe registered engineer, an unvented (G3) qualified installer, building regulations notification (Approved Documents G, J, L and others) and a water company notice (Water Fittings Regulations, regulation 5)? Returns, per job, who can do it, the self-certification route (competent person scheme within 30 days, or building control before starting) and what to do next, including CO alarm and Boiler Plus rules. Typical call: {"nation":"england","work":["gas_boiler_replacement","unvented_cylinder_new"]}.
{
"type": "object",
"required": [
"work"
],
"properties": {
"work": {
"type": "array",
"items": {
"enum": [
"gas_boiler_new",
"gas_boiler_replacement",
"gas_fire_or_appliance",
"gas_cooker",
"gas_pipework",
"gas_service_or_safety_check",
"gas_meter_move",
"oil_boiler_new_or_replacement",
"oil_tank",
"solid_fuel_stove",
"electric_boiler",
"heat_pump",
"unvented_cylinder_new",
"unvented_cylinder_replacement",
"vented_cylinder_replacement",
"heating_system_new",
"radiator_add_or_move",
"heating_controls_only",
"power_flush",
"bathroom_like_for_like",
"bathroom_new",
"bath_over_230_litres",
"bidet_ascending_spray",
"booster_pump",
"water_softener_or_treatment",
"reverse_osmosis",
"garden_watering_system",
"outside_tap",
"water_service_pipe",
"rpz_valve",
"solar_thermal"
],
"type": "string"
},
"description": "One or more jobs."
},
"trade": {
"type": "object",
"properties": {
"town": {
"type": "string"
},
"email": {
"type": "string"
},
"phone": {
"type": "string"
},
"address": {
"type": "string",
"description": "Business address for record headers."
},
"postcode": {
"type": "string"
},
"categories": {
"type": "array",
"items": {
"type": "string"
},
"description": "Trades offered, using Nero Work trade names. Defaults to [\"plumber\", \"heating\"]."
},
"company_name": {
"type": "string",
"description": "Registered company name, if a limited company."
},
"display_name": {
"type": "string",
"description": "Trading name shown to customers, for example \"Northside Plumbing & Heating\"."
},
"licence_body": {
"enum": [
"gas_safe",
"oftec",
"hetas",
"aphc",
"ciphe",
"watersafe",
"mcs",
"niceic",
"napit",
"stroma",
"certsure",
"benchmark",
"other",
"none"
],
"type": "string",
"description": "Registration scheme. For gas work use gas_safe with the business's Gas Safe registration number."
},
"company_number": {
"type": "string",
"description": "Companies House number, for example 12345678 or SC123456."
},
"licence_number": {
"type": "string",
"description": "Scheme registration number (Gas Safe registration numbers are usually 6 or 7 digits)."
}
},
"description": "Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack.",
"additionalProperties": false
},
"nation": {
"enum": [
"england",
"wales"
],
"type": "string",
"description": "Default england."
},
"water_approved_contractor": {
"type": "boolean",
"description": "True if the installer is a water approved contractor (for example WaterSafe)."
}
},
"additionalProperties": false
}{
"title": "Notifiable work check",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}check_gas_record — Check a gas safety record or commissioning record before issuing it
Checks a filled landlord gas safety record (CP12) or a boiler commissioning record and lists errors and warnings: missing required fields, failed tightness, flue, ventilation or safety device checks, CO/CO2 ratio over the limits, gas rate off the rated input, meter pressure out of range, an unsafe appliance marked safe, and the correct next due date (keeping the anniversary for checks done up to 2 months early). Gas safety record fields: property_address, landlord_name, landlord_address, engineer_name, gas_safe_registration_number, engineer_licence_number, check_date, previous_record_expiry_date, next_check_due, engineer_signature, tightness_test_passed, emergency_control_accessible, meter_standing_pressure_mbar, meter_working_pressure_mbar, appliances[] {type, make, model, location, flue_type, flue_check_passed, ventilation_satisfactory, safety_devices_ok, co_ppm, co2_percent, co_co2_ratio, rated_heat_input_kw_gross, measured_gas_rate_m3_h, inlet_working_pressure_mbar, status (safe, ncs, at_risk, immediately_dangerous), safe_to_use, action_taken}. Commissioning fields: property_address, engineer_name, commissioning_date, boiler_type, system_flushed, inhibitor_added, inhibitor_name, filter_fitted, water_hardness_ppm, scale_reducer_fitted, condensate_external_pipe_mm, controls_time_and_temperature, combi_extra_measure, co_alarm_fitted, building_regs_notified, dhw_flow_l_min, dhw_temp_rise_c, appliances[] {make, model, serial_number, co_ppm, co2_percent, min_rate {co_ppm, co2_percent}, rated_heat_input_kw_gross, measured_gas_rate_m3_h}. Up to 30 appliances.
{
"type": "object",
"required": [
"record_type",
"record"
],
"properties": {
"trade": {
"type": "object",
"properties": {
"town": {
"type": "string"
},
"email": {
"type": "string"
},
"phone": {
"type": "string"
},
"address": {
"type": "string",
"description": "Business address for record headers."
},
"postcode": {
"type": "string"
},
"categories": {
"type": "array",
"items": {
"type": "string"
},
"description": "Trades offered, using Nero Work trade names. Defaults to [\"plumber\", \"heating\"]."
},
"company_name": {
"type": "string",
"description": "Registered company name, if a limited company."
},
"display_name": {
"type": "string",
"description": "Trading name shown to customers, for example \"Northside Plumbing & Heating\"."
},
"licence_body": {
"enum": [
"gas_safe",
"oftec",
"hetas",
"aphc",
"ciphe",
"watersafe",
"mcs",
"niceic",
"napit",
"stroma",
"certsure",
"benchmark",
"other",
"none"
],
"type": "string",
"description": "Registration scheme. For gas work use gas_safe with the business's Gas Safe registration number."
},
"company_number": {
"type": "string",
"description": "Companies House number, for example 12345678 or SC123456."
},
"licence_number": {
"type": "string",
"description": "Scheme registration number (Gas Safe registration numbers are usually 6 or 7 digits)."
}
},
"description": "Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack.",
"additionalProperties": false
},
"record": {
"type": "object",
"description": "The filled fields (see the description)."
},
"record_type": {
"enum": [
"gas_safety_record",
"commissioning"
],
"type": "string"
}
},
"additionalProperties": false
}{
"title": "Gas record check",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}emergency_triage — Emergency triage for leaks, bursts, no heat, gas smell or CO alarm
For a homeowner reporting a problem: the safe first steps to do now, what not to do, who to call first (the gas emergency service 0800 111 999 for a gas smell or CO alarm), whether it is a real emergency, and an `urgency` value of routine, soon or emergency that matches Nero Work's three job speeds, raised for water near electrics, a bulging ceiling, a vulnerable person in the cold, or water that cannot be stopped. Also returns `nero_work_job` (urgency, category, summary) ready to post. Typical call: {"situation":"no_heat","vulnerable_people":true,"outside_temp_c":2,"other_heating_available":false}.
{
"type": "object",
"required": [
"situation"
],
"properties": {
"trade": {
"type": "object",
"properties": {
"town": {
"type": "string"
},
"email": {
"type": "string"
},
"phone": {
"type": "string"
},
"address": {
"type": "string",
"description": "Business address for record headers."
},
"postcode": {
"type": "string"
},
"categories": {
"type": "array",
"items": {
"type": "string"
},
"description": "Trades offered, using Nero Work trade names. Defaults to [\"plumber\", \"heating\"]."
},
"company_name": {
"type": "string",
"description": "Registered company name, if a limited company."
},
"display_name": {
"type": "string",
"description": "Trading name shown to customers, for example \"Northside Plumbing & Heating\"."
},
"licence_body": {
"enum": [
"gas_safe",
"oftec",
"hetas",
"aphc",
"ciphe",
"watersafe",
"mcs",
"niceic",
"napit",
"stroma",
"certsure",
"benchmark",
"other",
"none"
],
"type": "string",
"description": "Registration scheme. For gas work use gas_safe with the business's Gas Safe registration number."
},
"company_number": {
"type": "string",
"description": "Companies House number, for example 12345678 or SC123456."
},
"licence_number": {
"type": "string",
"description": "Scheme registration number (Gas Safe registration numbers are usually 6 or 7 digits)."
}
},
"description": "Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack.",
"additionalProperties": false
},
"nation": {
"enum": [
"england",
"wales",
"scotland",
"northern_ireland"
],
"type": "string",
"description": "Changes the gas emergency number for Northern Ireland."
},
"situation": {
"enum": [
"gas_smell",
"co_alarm",
"co_symptoms",
"burst_pipe",
"leak",
"water_through_ceiling",
"no_heat",
"no_hot_water",
"boiler_leaking",
"boiler_low_pressure",
"frozen_pipe",
"frozen_condensate",
"no_water",
"toilet_overflowing",
"blocked_drain",
"radiator_cold",
"dripping_tap",
"noisy_pipes"
],
"type": "string"
},
"pipe_split": {
"type": "boolean"
},
"only_toilet": {
"type": "boolean"
},
"sewage_inside": {
"type": "boolean"
},
"water_stopped": {
"type": "boolean",
"description": "Has turning off the stop tap or valve stopped the water?"
},
"outside_temp_c": {
"type": "number"
},
"ceiling_bulging": {
"type": "boolean"
},
"vulnerable_people": {
"type": "boolean",
"description": "Elderly, very young, disabled or medically vulnerable person in the home."
},
"water_near_electrics": {
"type": "boolean"
},
"other_heating_available": {
"type": "boolean"
}
},
"additionalProperties": false
}{
"title": "Emergency triage",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}trade_profile — Check the plumber or heating engineer's business details
Checks the business's own details (Nero Trade Profile v1: trading name, Companies House number, registration scheme and number, postcode, contact) and returns them cleaned, with a stable `nero_trade_ref` computed from the scheme registration (licence_body gas_safe plus the Gas Safe registration number) or the company number. The same shape and reference as Spark Pack, so one business keeps one reference across trades. The same object, given as `trade` to the other tools, prefills records. Flow Pack stores nothing. The same profile and reference can later be used to sign the business into Nero Work, the agent job exchange for trades.
{
"type": "object",
"required": [
"trade"
],
"properties": {
"trade": {
"type": "object",
"properties": {
"town": {
"type": "string"
},
"email": {
"type": "string"
},
"phone": {
"type": "string"
},
"address": {
"type": "string",
"description": "Business address for record headers."
},
"postcode": {
"type": "string"
},
"categories": {
"type": "array",
"items": {
"type": "string"
},
"description": "Trades offered, using Nero Work trade names. Defaults to [\"plumber\", \"heating\"]."
},
"company_name": {
"type": "string",
"description": "Registered company name, if a limited company."
},
"display_name": {
"type": "string",
"description": "Trading name shown to customers, for example \"Northside Plumbing & Heating\"."
},
"licence_body": {
"enum": [
"gas_safe",
"oftec",
"hetas",
"aphc",
"ciphe",
"watersafe",
"mcs",
"niceic",
"napit",
"stroma",
"certsure",
"benchmark",
"other",
"none"
],
"type": "string",
"description": "Registration scheme. For gas work use gas_safe with the business's Gas Safe registration number."
},
"company_number": {
"type": "string",
"description": "Companies House number, for example 12345678 or SC123456."
},
"licence_number": {
"type": "string",
"description": "Scheme registration number (Gas Safe registration numbers are usually 6 or 7 digits)."
}
},
"description": "Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack.",
"additionalProperties": false
}
},
"additionalProperties": false
}{
"title": "Check business details",
"readOnlyHint": true,
"openWorldHint": false,
"idempotentHint": true,
"destructiveHint": false
}Prompts
Not advertised
Resources
Not advertised
90-day uptime
A lightweight connection check about every six hours, sampled on hosts with many listings. It shows the server answered, not that its tools work.
- 2026-11-14: 1 of 1 checks answered
- 2026-11-15: 2 of 2 checks answered
- 2026-11-16: 4 of 4 checks answered
- 2026-11-17: 5 of 5 checks answered
- 2026-11-18: 5 of 5 checks answered
- 2026-11-19: 4 of 4 checks answered
- 2026-11-20: 3 of 3 checks answered
- 2026-11-21: 4 of 4 checks answered
- 2026-11-22: 4 of 4 checks answered
- 2026-11-23: 3 of 3 checks answered
- 2026-11-24: 4 of 4 checks answered
- 2026-11-25: 4 of 4 checks answered
- 2026-11-26: 4 of 4 checks answered
- 2026-11-27: 4 of 4 checks answered
- 2026-11-28: 2 of 2 checks answered
30-day availability
Aggregated from read-only remote checks; this is not a tool-execution or security guarantee.
- Successful checks
- 3 of 3 (100%)
- Average latency
- 483 ms
- 95th percentile latency
- 549 ms
Maintenance history
Public check and source-refresh events. Editorial and ownership records remain private.
- · probe · passed · 441 ms · 8 tool(s)
- · probe · passed · 447 ms · metadata changed · 8 tool(s)
- · probe · passed · 560 ms · metadata changed · 8 tool(s)
Connect from your client
Each snippet registers the same endpoint; pick the client you use.
Claude Code
claude mcp add --transport http flow-pack-mcp https://flow-pack.nerolabs.workers.dev/mcpCodex
codex mcp add flow-pack-mcp --url https://flow-pack.nerolabs.workers.dev/mcpCursor
{
"mcpServers": {
"flow-pack-mcp": {
"url": "https://flow-pack.nerolabs.workers.dev/mcp"
}
}
}Cline
{
"mcpServers": {
"flow-pack-mcp": {
"type": "streamableHttp",
"url": "https://flow-pack.nerolabs.workers.dev/mcp",
"disabled": false
}
}
}VS Code
{
"servers": {
"flow-pack-mcp": {
"type": "http",
"url": "https://flow-pack.nerolabs.workers.dev/mcp"
}
}
}Gemini CLI
gemini mcp add --transport http flow-pack-mcp https://flow-pack.nerolabs.workers.dev/mcpClaude Desktop
https://flow-pack.nerolabs.workers.dev/mcpWindsurf
{
"mcpServers": {
"flow-pack-mcp": {
"serverUrl": "https://flow-pack.nerolabs.workers.dev/mcp"
}
}
}Let your agent find its tools
Find servers like Flow Pack MCP from your agent. Add Koskamo once to search the index for endpoints, access requirements, and client setup. Public discovery needs no key.
Other developer tools servers
Frequently asked questions
- Can I use all tools without an account?
- No. While connecting to the server requires no sign-in, individual tools may still need a vendor account, credentials, or permissions. You must check the documented prerequisites for each specific task.
- What plumbing calculations are supported?
- The server supports calculating water or gas pipe size, velocity, and pressure loss. It also determines room-by-room heat loss to help size boilers or heat pumps.
- Does the server validate gas safety records?
- Yes. The check_gas_record tool validates landlord gas safety records for missing fields or errors. This is one of the specific compliance tasks supported by the server.