Constat MCP
An official MCP server by Health AI providing 14 tools for FDA and CMS medical device evidence. It enables AI agents to perform 510(k) precedent research, postmarket surveillance, reimbursement evidence tracing, and compliance monitoring using verbatim source quotes from public records.
Endpoint and access
No sign-in to connect and list tools. Individual tools may still need a vendor account, credentials, or permissions; check the documented prerequisites.
https://constat.dev/api/mcpWhat its tools do
14 tools, grouped by the hints the server advertises. Hints are self-declared, not verified behavior.
Checks and signals
Each line is separate evidence, not a trust score.
- Passed Endpoint answered the live check ·
- Passed Official MCP Registry namespace is tied to healthai.com ·
- Passed Endpoint and vendor documentation share a domain
- Uptime 0% over 90 days
- Availability 2 of 2 checks passed in 30 days
What you can do with it
- Trace predicate chains for 510(k) device clearance
- Query MAUDE trends and recall context for postmarket surveillance
- Trace clearance numbers to documented reimbursement mechanisms
- Monitor public-record changes for firm compliance history
Source and maintenance
- Repository status
- Unavailable (HTTP 404)
- Maintenance checked
Protocol and capabilities
- Server
- com.healthai/radar 0.5.3
- MCP protocol negotiated in check
- 2025-06-18
- Tools
- 14 advertised
- Resources
- Not advertised
- Resource templates
- Not advertised
- Prompts
- Not advertised
{
"tools": {}
}Tools
14 advertised
device_risk_lookup — Review Device Category Risk Signals
Review a medical-device category's public FDA signals by three-letter product code (e.g. FRN = infusion pump). Returns recalls, MAUDE adverse-event trend, warning-letter matches, a normalized category signal, its driver contributions, and interpretation limits. It does not predict enforcement against a firm.
{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"product_code"
],
"properties": {
"product_code": {
"type": "string",
"pattern": "^[A-Za-z]{3}$",
"description": "Three-letter FDA product code, e.g. FRN"
}
}
}{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"data",
"untrusted_data_notice"
],
"properties": {
"data": {
"anyOf": [
{},
{
"type": "null"
}
]
},
"status": {
"enum": [
"ok",
"not_found",
"invalid_request",
"unavailable"
],
"type": "string"
},
"message": {
"type": "string"
},
"untrusted_data_notice": {
"type": "string"
}
},
"additionalProperties": false
}{
"title": "Review Device Category Risk Signals",
"readOnlyHint": false,
"openWorldHint": false,
"destructiveHint": false
}firm_compliance_history — Review Firm Compliance History
Build a recent, source-bounded FDA public-record timeline for a device firm: matched recalls, warning letters, and Form 483 citations where exact FEI numbers are available. Product codes are discovered from Constat's AI/ML-device corpus or may be supplied explicitly. Returns attribution and coverage limits with the records; it is not a finding of noncompliance or a prediction of FDA action.
{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"firm_name"
],
"properties": {
"limit": {
"type": "integer",
"maximum": 50,
"minimum": 1,
"description": "Maximum records per source and events in the timeline (default 20)."
},
"since": {
"type": "string",
"pattern": "^\\d{4}-\\d{2}-\\d{2}$",
"description": "Earliest event date, YYYY-MM-DD. Defaults to five years ago."
},
"firm_name": {
"type": "string",
"maxLength": 160,
"minLength": 2,
"description": "FDA applicant or company name, e.g. 'Medtronic'"
},
"fei_numbers": {
"type": "array",
"items": {
"type": "string",
"pattern": "^\\d{6,12}$"
},
"maxItems": 20,
"description": "Optional exact FDA FEI numbers; improves Form 483 attribution."
},
"product_codes": {
"type": "array",
"items": {
"type": "string",
"pattern": "^[A-Za-z0-9]{3}$"
},
"maxItems": 8,
"description": "Optional FDA product-code scope. When omitted, Constat discovers codes from applicant matches in its device corpus."
}
}
}{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"data",
"untrusted_data_notice"
],
"properties": {
"data": {
"anyOf": [
{},
{
"type": "null"
}
]
},
"status": {
"enum": [
"ok",
"not_found",
"invalid_request",
"unavailable"
],
"type": "string"
},
"message": {
"type": "string"
},
"untrusted_data_notice": {
"type": "string"
}
},
"additionalProperties": false
}{
"title": "Review Firm Compliance History",
"readOnlyHint": false,
"openWorldHint": false,
"destructiveHint": false
}watchlist_diff — Poll Watchlist Changes
Return machine-generated FDA public-record changes detected for monitored product codes since a caller-supplied date, plus each code's latest category snapshot and postmarket coverage. Defaults to Constat Radar's five-code watchlist and the last seven days. Analyst verdict text and internal review status are excluded; use next_since as the next polling cursor.
{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"properties": {
"limit": {
"type": "integer",
"maximum": 100,
"minimum": 1,
"description": "Maximum changes to return (default 10)."
},
"since": {
"type": "string",
"pattern": "^\\d{4}-\\d{2}-\\d{2}(?:T\\d{2}:\\d{2}:\\d{2}(?:\\.\\d{1,3})?Z)?$",
"description": "Return changes on or after this ISO date or UTC timestamp. Defaults to the last seven days; pass the prior response's next_since for exact polling."
},
"product_codes": {
"type": "array",
"items": {
"type": "string",
"pattern": "^[A-Za-z0-9]{3}$"
},
"maxItems": 20,
"description": "FDA product codes to poll. Omit for the default Radar watchlist."
}
}
}{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"data",
"untrusted_data_notice"
],
"properties": {
"data": {
"anyOf": [
{},
{
"type": "null"
}
]
},
"status": {
"enum": [
"ok",
"not_found",
"invalid_request",
"unavailable"
],
"type": "string"
},
"message": {
"type": "string"
},
"untrusted_data_notice": {
"type": "string"
}
},
"additionalProperties": false
}{
"title": "Poll Watchlist Changes",
"readOnlyHint": false,
"openWorldHint": false,
"destructiveHint": false
}device_evidence_lookup — Look Up Device Evidence
Look up the structured premarket evidence FDA accepted for a specific AI/ML-enabled device by 510(k) number (e.g. K252148). Returns parsed summary fields — validation study design, sample sizes, endpoints, reported performance, predicate chain, PCCP — each with a verbatim source quote and page. Null means the summary did not state it.
{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"k_number"
],
"properties": {
"k_number": {
"type": "string",
"pattern": "^(K|DEN)\\d{6}$",
"description": "510(k) or De Novo number, e.g. K252148 or DEN180001"
}
}
}{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"data",
"untrusted_data_notice"
],
"properties": {
"data": {
"anyOf": [
{},
{
"type": "null"
}
]
},
"status": {
"enum": [
"ok",
"not_found",
"invalid_request",
"unavailable"
],
"type": "string"
},
"message": {
"type": "string"
},
"untrusted_data_notice": {
"type": "string"
}
},
"additionalProperties": false
}{
"title": "Look Up Device Evidence",
"readOnlyHint": false,
"openWorldHint": false,
"destructiveHint": false
}evidence_search — Search Device Evidence
Find AI/ML device clearances by filter — product code, panel, applicant, and whether the submission reported clinical data, any sensitivity metric, or a PCCP. Answers 'what evidence did FDA accept for devices like mine'. Returns bounded discovery summaries; call device_evidence_lookup with a result's K-number for the full source-quoted FDA record. Presence flags are descriptive: 'reports a sensitivity metric' is not 'reports a comparable sensitivity' — analysis units differ across devices.
{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"properties": {
"limit": {
"type": "integer",
"maximum": 50,
"minimum": 1
},
"panel": {
"type": "string",
"maxLength": 80,
"description": "Advisory panel, e.g. Radiology"
},
"cursor": {
"type": "string",
"maxLength": 512,
"description": "Opaque continuation cursor returned by a prior page."
},
"has_pccp": {
"type": "boolean",
"description": "Included a Predetermined Change Control Plan"
},
"applicant": {
"type": "string",
"maxLength": 120,
"description": "Substring match on applicant/company name"
},
"product_code": {
"type": "string",
"pattern": "^[A-Za-z0-9]{3}$",
"description": "FDA product code, e.g. QAS"
},
"has_clinical_data": {
"type": "boolean"
},
"reports_any_sensitivity_metric": {
"type": "boolean",
"description": "Reported any sensitivity metric (canonical — includes per-finding sensitivities, not just the top-level slot). Not a claim of cross-device comparability."
}
}
}{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"data",
"untrusted_data_notice"
],
"properties": {
"data": {
"anyOf": [
{
"type": "object",
"required": [
"count",
"results"
],
"properties": {
"count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0
},
"results": {
"type": "array",
"items": {}
},
"scanned": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0
},
"truncated": {
"type": "boolean"
},
"next_cursor": {
"type": "string"
}
},
"additionalProperties": false
},
{
"type": "null"
}
]
},
"status": {
"enum": [
"ok",
"not_found",
"invalid_request",
"unavailable"
],
"type": "string"
},
"message": {
"type": "string"
},
"untrusted_data_notice": {
"type": "string"
}
},
"additionalProperties": false
}{
"title": "Search Device Evidence",
"readOnlyHint": false,
"openWorldHint": false,
"destructiveHint": false
}predicate_chain — Trace Predicate Chain
Trace the predicate ancestry of a 510(k) device, with each cited predicate's age (how many years old the predicate was when the child cleared). Reveals how AI/ML devices chain to older predicates.
{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"k_number"
],
"properties": {
"depth": {
"type": "integer",
"maximum": 6,
"minimum": 1,
"description": "Max ancestry depth (default 4)"
},
"k_number": {
"type": "string",
"pattern": "^(K|DEN)\\d{6}$",
"description": "510(k) or De Novo number, e.g. K252148 or DEN180001"
}
}
}{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"data",
"untrusted_data_notice"
],
"properties": {
"data": {
"anyOf": [
{
"type": "object",
"required": [
"root",
"chain",
"truncated"
],
"properties": {
"root": {
"type": "string"
},
"chain": {
"type": "array",
"items": {}
},
"truncated": {
"type": "boolean"
}
},
"additionalProperties": false
},
{
"type": "null"
}
]
},
"status": {
"enum": [
"ok",
"not_found",
"invalid_request",
"unavailable"
],
"type": "string"
},
"message": {
"type": "string"
},
"untrusted_data_notice": {
"type": "string"
}
},
"additionalProperties": false
}{
"title": "Trace Predicate Chain",
"readOnlyHint": false,
"openWorldHint": false,
"destructiveHint": false
}evidence_cohort_stats — Summarize Evidence Cohort
Reporting-rate stats across the parsed AI/ML corpus (optionally by panel). Each rate is a presence figure with its denominator — 'reported in X of Y audited devices' — never a pooled performance value. Excludes not-yet-parsed devices from every denominator and discloses the parse queue separately. Predicate age (median years between a clearance and its cited predicates) is included when decision-date coverage clears a 60% floor, and withheld otherwise.
{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"properties": {
"panel": {
"type": "string",
"maxLength": 80,
"description": "Advisory panel, e.g. Radiology; omit for all"
}
}
}{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"data",
"untrusted_data_notice"
],
"properties": {
"data": {
"anyOf": [
{},
{
"type": "null"
}
]
},
"status": {
"enum": [
"ok",
"not_found",
"invalid_request",
"unavailable"
],
"type": "string"
},
"message": {
"type": "string"
},
"untrusted_data_notice": {
"type": "string"
}
},
"additionalProperties": false
}{
"title": "Summarize Evidence Cohort",
"readOnlyHint": false,
"openWorldHint": false,
"destructiveHint": false
}device_postmarket_lookup — Look Up Device Postmarket Signals
Post-clearance intelligence for one AI/ML device by 510(k) number: its product code's recalls, MAUDE adverse-event level and trend, warning-letter and 483 matches for the applicant, plus per-device drift signals (adverse-event inflection, re-clearances of the same device line, software-recall patterns, predicate-cohort recall activity). Descriptive observables with sources — never a safety judgment.
{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"k_number"
],
"properties": {
"k_number": {
"type": "string",
"pattern": "^(K|DEN)\\d{6}$",
"description": "510(k) or De Novo number, e.g. K252148 or DEN180001"
}
}
}{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"data",
"untrusted_data_notice"
],
"properties": {
"data": {
"anyOf": [
{},
{
"type": "null"
}
]
},
"status": {
"enum": [
"ok",
"not_found",
"invalid_request",
"unavailable"
],
"type": "string"
},
"message": {
"type": "string"
},
"untrusted_data_notice": {
"type": "string"
}
},
"additionalProperties": false
}{
"title": "Look Up Device Postmarket Signals",
"readOnlyHint": false,
"openWorldHint": false,
"destructiveHint": false
}postmarket_search — Search Postmarket Signals
Find AI/ML devices by postmarket criteria — product code, panel, applicant, whether any drift signal exists, minimum recalls in 24 months, or a rising MAUDE trend. Returns per-device postmarket summaries with drift-signal counts.
{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"properties": {
"limit": {
"type": "integer",
"maximum": 50,
"minimum": 1
},
"panel": {
"type": "string",
"maxLength": 80,
"description": "Advisory panel, e.g. Radiology"
},
"cursor": {
"type": "string",
"maxLength": 512,
"description": "Opaque continuation cursor returned by a prior page."
},
"applicant": {
"type": "string",
"maxLength": 120,
"description": "Substring match on applicant/company name"
},
"product_code": {
"type": "string",
"pattern": "^[A-Za-z0-9]{3}$",
"description": "FDA product code, e.g. QIH"
},
"maude_trend_up": {
"type": "boolean",
"description": "Code-level MAUDE trend above its own 3-year baseline"
},
"has_drift_signal": {
"type": "boolean"
},
"min_recalls_24mo": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0,
"description": "Product-code recalls in trailing 24 months"
},
"signal_specificity": {
"enum": [
"device",
"product_code"
],
"type": "string",
"description": "Restrict the drift-signal filter to one tier: 'device' = attributable to this device (own line re-cleared, own applicant's recall, predicate neighbors) — the high-signal tier; 'product_code' = observed in its category"
}
}
}{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"data",
"untrusted_data_notice"
],
"properties": {
"data": {
"anyOf": [
{
"type": "object",
"required": [
"count",
"results"
],
"properties": {
"count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0
},
"results": {
"type": "array",
"items": {}
},
"scanned": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0
},
"truncated": {
"type": "boolean"
},
"next_cursor": {
"type": "string"
}
},
"additionalProperties": false
},
{
"type": "null"
}
]
},
"status": {
"enum": [
"ok",
"not_found",
"invalid_request",
"unavailable"
],
"type": "string"
},
"message": {
"type": "string"
},
"untrusted_data_notice": {
"type": "string"
}
},
"additionalProperties": false
}{
"title": "Search Postmarket Signals",
"readOnlyHint": false,
"openWorldHint": false,
"destructiveHint": false
}cohort_postmarket_stats — Summarize Postmarket Cohort
Postmarket presence rates across the snapshotted AI/ML device cohort (optionally by panel): share with any recall in 24 months, with a rising MAUDE trend, with any drift signal, with a warning-letter match — every rate with its denominator inline, never pooled across devices.
{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"properties": {
"panel": {
"type": "string",
"maxLength": 80,
"description": "Advisory panel, e.g. Radiology; omit for all"
}
}
}{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"data",
"untrusted_data_notice"
],
"properties": {
"data": {
"anyOf": [
{},
{
"type": "null"
}
]
},
"status": {
"enum": [
"ok",
"not_found",
"invalid_request",
"unavailable"
],
"type": "string"
},
"message": {
"type": "string"
},
"untrusted_data_notice": {
"type": "string"
}
},
"additionalProperties": false
}{
"title": "Summarize Postmarket Cohort",
"readOnlyHint": false,
"openWorldHint": false,
"destructiveHint": false
}reimbursement_lookup — Look Up Reimbursement Pathways
Trace the clearance-to-payment pathway for an AI/ML device by FDA clearance number (K/DEN, e.g. DEN170073) OR bare CPT code (e.g. 75580). Returns every payment mechanism (NTAP add-on, Category I/III CPT + CMS rate, HCPCS, MAC LCD) with amounts, effective dates, and source links, plus any commercial/MAC payer coverage policies that reference the clearance or its codes. Answers 'who got paid, how much, through which mechanism, on what basis.' CPT codes are bare factual identifiers only — no procedure descriptors; follow the CMS source link for the official descriptor.
{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"properties": {
"cpt_code": {
"type": "string",
"pattern": "^\\d{4,5}[A-Z]?$",
"description": "Bare CPT code, e.g. 75580 or 0932T"
},
"k_number": {
"type": "string",
"pattern": "^(K|DEN)\\d{6}$",
"description": "FDA clearance number, e.g. DEN170073 or K252148"
}
}
}{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"data",
"untrusted_data_notice"
],
"properties": {
"data": {
"anyOf": [
{},
{
"type": "null"
}
]
},
"status": {
"enum": [
"ok",
"not_found",
"invalid_request",
"unavailable"
],
"type": "string"
},
"message": {
"type": "string"
},
"untrusted_data_notice": {
"type": "string"
}
},
"additionalProperties": false
}{
"title": "Look Up Reimbursement Pathways",
"readOnlyHint": false,
"openWorldHint": false,
"destructiveHint": false
}reimbursement_search — Search Reimbursement Pathways
Find AI/ML device payment pathways by mechanism — e.g. 'devices that got NTAP', 'devices paid under a Category I CPT code', 'pathways with a known CMS dollar rate'. Filters: mechanism, CPT category, NTAP status, applicant. Returns pathways with amounts, effective dates, and sources. Use reimbursement_stats for the mechanism distribution (never a single pooled reimbursement rate).
{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"properties": {
"limit": {
"type": "integer",
"maximum": 50,
"minimum": 1
},
"cursor": {
"type": "string",
"maxLength": 512,
"description": "Opaque continuation cursor returned by a prior page."
},
"applicant": {
"type": "string",
"maxLength": 120,
"description": "Substring match on device maker / applicant name"
},
"mechanism": {
"enum": [
"ntap",
"cat_iii_apc",
"cat_i",
"hcpcs",
"lcd",
"none"
],
"type": "string",
"description": "Payment mechanism"
},
"ntap_status": {
"enum": [
"active",
"expired",
"granted",
"none"
],
"type": "string"
},
"cpt_category": {
"enum": [
"I",
"III",
"unknown"
],
"type": "string",
"description": "CPT category"
},
"has_cms_rate": {
"type": "boolean",
"description": "Only pathways with a known CMS dollar rate"
}
}
}{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"data",
"untrusted_data_notice"
],
"properties": {
"data": {
"anyOf": [
{
"type": "object",
"required": [
"count",
"results"
],
"properties": {
"count": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0
},
"results": {
"type": "array",
"items": {}
},
"scanned": {
"type": "integer",
"maximum": 9007199254740991,
"minimum": 0
},
"truncated": {
"type": "boolean"
},
"next_cursor": {
"type": "string"
}
},
"additionalProperties": false
},
{
"type": "null"
}
]
},
"status": {
"enum": [
"ok",
"not_found",
"invalid_request",
"unavailable"
],
"type": "string"
},
"message": {
"type": "string"
},
"untrusted_data_notice": {
"type": "string"
}
},
"additionalProperties": false
}{
"title": "Search Reimbursement Pathways",
"readOnlyHint": false,
"openWorldHint": false,
"destructiveHint": false
}reimbursement_stats — Summarize Reimbursement Cohort
Distribution of payment mechanisms across the AI/ML reimbursement corpus — pathway and distinct-device counts per mechanism (NTAP, Cat I, Cat III/APC, …) with the min/median/max dollar amounts for each. Deliberately never a single pooled 'reimbursement rate': NTAP add-on amounts and CMS rates are different measurements and are reported separately with their own spreads.
{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"properties": {}
}{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"data",
"untrusted_data_notice"
],
"properties": {
"data": {
"anyOf": [
{},
{
"type": "null"
}
]
},
"status": {
"enum": [
"ok",
"not_found",
"invalid_request",
"unavailable"
],
"type": "string"
},
"message": {
"type": "string"
},
"untrusted_data_notice": {
"type": "string"
}
},
"additionalProperties": false
}{
"title": "Summarize Reimbursement Cohort",
"readOnlyHint": false,
"openWorldHint": false,
"destructiveHint": false
}vehicle_risk_lookup — Look Up Vehicle Safety History
Look up NHTSA safety history for a vehicle by make, model, and model year. Returns recall campaigns and complaint statistics (crashes, fires, injuries, top components).
{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"make",
"model",
"year"
],
"properties": {
"make": {
"type": "string",
"maxLength": 64,
"minLength": 2,
"description": "e.g. honda"
},
"year": {
"type": "string",
"pattern": "^\\d{4}$",
"description": "model year, e.g. 2020"
},
"model": {
"type": "string",
"maxLength": 64,
"minLength": 1,
"description": "e.g. civic"
}
}
}{
"type": "object",
"$schema": "http://json-schema.org/draft-07/schema#",
"required": [
"status",
"data",
"untrusted_data_notice"
],
"properties": {
"data": {
"anyOf": [
{},
{
"type": "null"
}
]
},
"status": {
"enum": [
"ok",
"not_found",
"invalid_request",
"unavailable"
],
"type": "string"
},
"message": {
"type": "string"
},
"untrusted_data_notice": {
"type": "string"
}
},
"additionalProperties": false
}{
"title": "Look Up Vehicle Safety History",
"readOnlyHint": false,
"openWorldHint": false,
"destructiveHint": false
}Prompts
Not advertised
Resources
Not advertised
90-day uptime
A lightweight connection check about every six hours, sampled on hosts with many listings. It shows the server answered, not that its tools work.
- 2026-11-02: 0 of 3 checks answered
- 2026-11-03: 0 of 4 checks answered
- 2026-11-04: 0 of 4 checks answered
- 2026-11-05: 0 of 4 checks answered
- 2026-11-06: 0 of 4 checks answered
- 2026-11-07: 0 of 2 checks answered
- 2026-11-09: 0 of 1 checks answered
- 2026-11-10: 0 of 2 checks answered
- 2026-11-11: 0 of 1 checks answered
- 2026-11-12: 0 of 1 checks answered
- 2026-11-14: 0 of 1 checks answered
- 2026-11-15: 0 of 2 checks answered
- 2026-11-16: 0 of 4 checks answered
- 2026-11-17: 0 of 5 checks answered
- 2026-11-18: 0 of 5 checks answered
- 2026-11-19: 0 of 4 checks answered
- 2026-11-20: 0 of 3 checks answered
- 2026-11-21: 0 of 4 checks answered
- 2026-11-22: 0 of 4 checks answered
- 2026-11-23: 0 of 3 checks answered
- 2026-11-24: 0 of 4 checks answered
- 2026-11-25: 0 of 4 checks answered
- 2026-11-26: 0 of 4 checks answered
- 2026-11-27: 0 of 3 checks answered
30-day availability
Aggregated from read-only remote checks; this is not a tool-execution or security guarantee.
- Successful checks
- 2 of 2 (100%)
- Average latency
- 2071 ms
- 95th percentile latency
- 2423 ms
Maintenance history
Public check and source-refresh events. Editorial and ownership records remain private.
- · probe · passed · 1680 ms · 14 tool(s)
- · probe · passed · 2462 ms · metadata changed · 14 tool(s)
- · repository · passed · unavailable
- · repository · passed · metadata changed · unavailable
- · repository · failed · Repository maintenance failed
- · registry · passed · metadata changed · Source metadata updated
- · registry · passed · metadata changed · Source metadata updated
- · backfill · recorded · Pre-expansion baseline; unobserved rich metadata remains unknown
Connect from your client
Each snippet registers the same endpoint; pick the client you use.
Claude Code
claude mcp add --transport http constat-mcp https://constat.dev/api/mcpCodex
codex mcp add constat-mcp --url https://constat.dev/api/mcpCursor
{
"mcpServers": {
"constat-mcp": {
"url": "https://constat.dev/api/mcp"
}
}
}Cline
{
"mcpServers": {
"constat-mcp": {
"type": "streamableHttp",
"url": "https://constat.dev/api/mcp",
"disabled": false
}
}
}VS Code
{
"servers": {
"constat-mcp": {
"type": "http",
"url": "https://constat.dev/api/mcp"
}
}
}Gemini CLI
gemini mcp add --transport http constat-mcp https://constat.dev/api/mcpClaude Desktop
https://constat.dev/api/mcpWindsurf
{
"mcpServers": {
"constat-mcp": {
"serverUrl": "https://constat.dev/api/mcp"
}
}
}Let your agent find its tools
Find servers like Constat MCP from your agent. Add Koskamo once to search the index for endpoints, access requirements, and client setup. Public discovery needs no key.
Other ai and machine learning servers
Do you run Constat MCP?
Prove ownership with a DNS record, a well-known file, or your Official MCP Registry entry, and your edits publish immediately. Proofs are re-checked weekly; admins can still hide or remove a listing.